PACi Elite, Unité murale • R410A

The extension of the range to include a 10kW unit allows for many more applications such as studios, gyms, high ceiling areas and even computer server rooms.

The unit’s compact design and flat face ensure discreet installation, even in a small space.

  • R32 refrigerant is more environmentally friendly than R410A
  • Aerowings to control air draft direction
  • Designed for 24h/7d a week operation
  • Up to A+++ in cooling
  • Highly efficient even at -20 °C
  • High durability rolling bearings
  • Additional piping sensors to prevent freezing
  • Automatic restart

Caractéristiques

Voir tout
PACi Elite, Unité murale • R410A Monophasé Triphasé
36 kW 50 kW 61 kW 71 kW 95 kW 71 kW 95 kW
EER (Nominal) (1) W/W 4,56 (6,25 - 4,30) A 3,57 (6,25 - 3,26) A 3,53 (6,67 - 3,02) A 3,40 (5,56 - 3,02) A 3,25 (3,93 - 3,09) A 3,40 (5,71 - 3,02) A 3,25 (3,93 - 3,09) A
COP (Nominal) (1) W/W 4,71 (7,89 - 4,20) A 3,94 (7,89 - 3,39) A 4,22 (9,00 - 3,90) A 4,00 (5,00 - 3,10) A 3,97 (4,56 - 3,43) A 4,00 (5,60 - 3,10) A 3,97 (4,56 - 3,43) A
Kit KIT-36PK2E5D KIT-50PK2E5D KIT-60PK2E5D KIT-71PK2E5D KIT-100PK2E5D KIT-71PK2E8D KIT-100PK2E8D
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,60 5,00 6,10 7,10 9,50 7,10 9,50
Cooling capacity (Min) kW 1,50 1,50 2,00 2,50 3,30 3,20 3,30
Cooling capacity (Max) kW 4,00 5,60 7,10 8,00 10,50 8,00 10,50
EER (Nominal) (1) W/W 4,56 3,57 3,53 3,40 3,25 3,40 3,25
EER (Min) (1) W/W 6,25 6,25 6,67 5,56 3,93 5,71 3,93
EER (Max) (1) W/W 4,30 3,26 3,02 3,02 3,09 3,02 3,09
SEER (2) 6,40 A++ 6,20 A++ 6,40 A++ 6,70 A++ 6,30 A++ 6,50 A++ 6,10 A+
Pdesign (cooling) kW 3,60 5,00 6,10 7,10 9,50 7,10 9,50
Input power cooling (Nominal) kW 0,79 1,40 1,68 2,09 2,92 2,09 2,92
Input power cooling (Min) kW 0,24 0,24 0,30 0,45 0,84 0,56 0,84
Input power cooling (Max) kW 0,93 1,72 2,35 2,65 3,40 2,65 3,40
Annual energy consumption cooling (3) kWh/a 197 282 319 371 528 382 545
Heating capacity (Nominal) kW 4,00 5,60 7,00 8,00 9,50 8,00 9,50
Heating capacity (Min) kW 1,50 1,50 1,80 2,00 4,10 2,80 4,10
Heating capacity (Max) kW 5,00 6,50 8,00 9,00 11,50 9,00 11,50
COP (Nominal) (1) W/W 4,71 3,94 4,22 4,00 3,97 4,00 3,97
COP (Min) (1) W/W 7,89 7,89 9,00 5,00 4,56 5,60 4,56
COP (Max) (1) W/W 4,20 3,39 3,90 3,10 3,43 3,10 3,43
SCOP (2) 4,30 A+ 4,10 A+ 4,20 A+ 4,10 A+ 3,80 A 4,10 A+ 4,00 A+
Pdesign at -10°C kW 3,60 5,00 6,00 7,10 9,50 7,10 9,50
Input power heating (Nominal) kW 0,85 1,42 1,66 2,00 2,92 2,00 2,39
Input power heating (Min) kW 0,19 0,19 0,20 0,40 0,84 0,50 0,90
Input power heating (Max) kW 1,19 1,92 2,05 2,90 3,40 2,90 3,35
Annual energy consumption heating (3) kWh/a 1172 1707 2000 2424 3325 2424 3325
Indoor unit S-36PK2E5B S-50PK2E5B S-60PK2E5B S-71PK2E5B S-100PK2E5B S-71PK2E5B S-100PK2E5B
Indoor air flow (Hi) m³/min 13,00 16,00 20,00 20,00 22,00 20,00 22,00
Indoor air flow (Med) m³/min 11,00 17,50 17,50 17,50 18,50 17,50 18,50
Indoor air flow (Lo) m³/min 9,00 11,00 14,50 14,50 15,00 14,50 15,00
Indoor sound pressure (Hi) (5) dB(A) 35 40 47 47 49 47 49
Indoor sound pressure (Med) (5) dB(A) 31 36 44 44 45 44 45
Indoor sound pressure (Lo) (5) dB(A) 27 32 40 40 41 40 41
Indoor dimension (Height) mm 302 302 302 302 302 302 302
Indoor dimension (Width) mm 1120 1120 1120 1120 1120 1120 1120
Indoor dimension (Depth) mm 236 236 236 236 236 236 236
Indoor net weight kg 13 13 14 14 14 14 14
Outdoor unit U-36PE2E5A U-50PE2E5A U-60PE2E5A U-71PE1E5A U-100PE1E5A U-71PE1E8A U-100PE1E8A
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415
Outdoor recommended fuse A 16 16
Outdoor connection indoor / outdoor mm² 2,5 2,5
Current in cooling (1p 220V / 3p 380) A 3,85 6,60 8,45 9,70 13,40 3,25 4,60
Current in cooling (1p 230V / 3p 400) A 3,70 6,30 8,05 9,40 12,90 3,10 4,35
Current in cooling (1p 240V / 3p 415) A 3,55 6,05 9,75 9,10 12,40 3,00 4,30
Current in heating (1p 220V / 3p 380) A 4,15 6,75 8,10 9,20 10,90 3,05 3,70
Current in heating (1p 230V / 3p 400) A 3,95 6,45 7,75 8,40 10,50 3,00 3,55
Current in heating (1p 240V / 3p 415) A 3,80 6,20 7,40 8,60 10,20 2,85 3,45
Outdoor air flow (Cool) m³/min 38 38 38 60 110 60 110
Outdoor air flow (Heat) m³/min 38 41 41 60 95 60 95
Outdoor sound pressure (Cool -Hi) dB(A) 45 46 46 48 52 48 52
Outdoor sound pressure (Heat -Hi) dB(A) 46 48 49 50 52 50 52
Outdoor dimension (Height) mm 619 619 619 996 1416 996 1416
Outdoor dimension (Width) mm 799 799 799 940 940 940 940
Outdoor dimension (Depth) mm 299 299 299 340 340 340 340
Outdoor net weight kg 39 39 40 69 98 71 98
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 75 5 ~ 50 5 ~ 75
Elevation difference (in/out) (5) m 30 30 30 30 30 30 30
Pipe length for additional gas m 30 30 30 30 30 30 30
Additional gas amount g/m 20 20 40 50 50 50 50
Refrigerant (R410A) / CO2 Eq. kg / T 1,40 / 2,9232 1,40 / 2,9232 1,95 / 4,0716 2,35 / 4,9068 3,40 / 7,0992 2,35 / 4,9068 3,40 / 7,0992
Operating range (Cool - Min) °C -15 -15 -15 -15 -15 -15 -15
Operating range (Cool - Max) °C +46 +46 +46 +46 +46 +46 +46
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.

* Only one of these can be used at a time.