Modèles
Large capacity PACi. Trusted power and high efficiency.
- High performance turbo fan, path system for heat exchanger
- nanoe™ X that improves indoor air quality
- Econavi: Intelligent sensor to reduce waste of energy
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Lower noise in slow fan operation
- Light weight, easy piping
- Drain pump included
Une large gamme de solutions pour les commerces,
les bureaux ou le logement
Gamme tertiaire air-air
PACi Standard ou Elite
Deux solutions idéales pour les commerces, les bureaux et le logement.
Caractéristiques
PACi Standard, cassette 4 voies 90x90 • R410 | Monophasé | Triphasé | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
10 kW | 60 kW | 71 kW | 100 kW | 125 kW | 100 kW | 125 kW | 140 kW | ||||||||||||
EER (Nominal) (1) | W/W | 3,70 (8,00 - 3,23) A | 3,24 (8,00 - 2,91) A | 4,27 (4,29 - 3,38) A | 3,16 (4,22 - 2,77) B | 3,16 (5,09 - 2,74) B | 3,16 (4,22 - 2,77) B | 3,25 (3,93 - 267) A | |||||||||||
COP (Nominal) (1) | W/W | 4,20 (9,00 - 4,24) A | 4,13 (9,00 - 3,68) A | 5,00 (5,19 - 3,18) A | 4,10 (4,66 - 3,41) A | 4,15 (5,12 - 3,45) A | 4,10 (4,66 - 3,41) A | 4,15 (4,56 - 3,08) A | |||||||||||
Kit | KIT-60PUY2E5D | KIT-71PUY2E5D | KIT-100PUY2E5D | KIT-125PUY2E5D | KIT-100PUY2E8D | KIT-125PUY2E8D | KIT-140PUY2E8D | ||||||||||||
Remote controller | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||||||||||||
Cooling capacity (Nominal) | kW | 6,00 | 7,10 | 10,00 | 12,50 | 10,00 | 12,50 | 14,00 | |||||||||||
Cooling capacity (Min) | kW | 2,00 | 2,00 | 3,30 | 3,80 | 2,70 | 3,80 | 3,30 | |||||||||||
Cooling capacity (Max) | kW | 7,10 | 7,70 | 12,50 | 13,50 | 11,50 | 13,50 | 15,50 | |||||||||||
EER (Nominal) (1) | W/W | 3,70 | 3,24 | 4,27 | 3,16 | 3,16 | 3,16 | 3,25 | |||||||||||
EER (Min) (1) | W/W | 8,00 | 8,00 | 4,29 | 4,22 | 5,09 | 4,22 | 3,93 | |||||||||||
EER (Max) (1) | W/W | 3,23 | 2,91 | 3,38 | 2,77 | 2,74 | 2,77 | 2,67 | |||||||||||
SEER (2) | 7,00 A++ | 6,50 A++ | 7,60 A++ | 6,22 | 6,60 A++ | 6,20 | 6,39 | ||||||||||||
Pdesign (cooling) | kW | 6,00 | 7,10 | 10,00 | 12,50 | 10,00 | 12,50 | 14,00 | |||||||||||
Input power cooling (Nominal) | kW | 1,62 | 2,19 | 2,34 | 3,96 | 3,16 | 3,96 | 4,31 | |||||||||||
Input power cooling (Min) | kW | 0,25 | 0,25 | 0,77 | 0,90 | 0,53 | 0,90 | 0,84 | |||||||||||
Input power cooling (Max) | kW | 2,20 | 2,65 | 3,70 | 4,88 | 4,20 | 4,88 | 5,81 | |||||||||||
Annual energy consumption cooling (3) | kWh/a | 300 | 382 | 461 | — | 530 | — | — | |||||||||||
Heating capacity (Nominal) | kW | 6,00 | 7,10 | 11,20 | 12,50 | 10,00 | 12,50 | 14,00 | |||||||||||
Heating capacity (Min) | kW | 1,80 | 1,80 | 4,10 | 3,40 | 2,10 | 3,40 | 4,10 | |||||||||||
Heating capacity (Max) | kW | 7,00 | 8,10 | 14,00 | 15,00 | 13,80 | 15,00 | 16,00 | |||||||||||
COP (Nominal) (1) | W/W | 4,20 | 4,13 | 5,00 | 4,10 | 4,15 | 4,10 | 4,15 | |||||||||||
COP (Min) (1) | W/W | 9,00 | 9,00 | 5,19 | 4,66 | 5,12 | 4,66 | 4,56 | |||||||||||
COP (Max) (1) | W/W | 4,24 | 3,68 | 3,18 | 3,41 | 3,45 | 3,41 | 3,08 | |||||||||||
SCOP (2) | 4,10 A+ | 4,20 A+ | 4,80 A++ | 3,87 | 4,30 A+ | 3,87 | 3,79 | ||||||||||||
Pdesign at -10°C | kW | 6,00 | 6,00 | 10,00 | 12,50 | 10,00 | 12,50 | 14,00 | |||||||||||
Input power heating (Nominal) | kW | 1,43 | 1,72 | 2,24 | 3,05 | 2,41 | 3,05 | 3,37 | |||||||||||
Input power heating (Min) | kW | 0,20 | 0,20 | 0,79 | 0,73 | 0,41 | 0,73 | 0,90 | |||||||||||
Input power heating (Max) | kW | 1,65 | 2,20 | 4,40 | 4,40 | 4,00 | 4,40 | 5,20 | |||||||||||
Annual energy consumption heating (3) | kWh/a | 2047 | 2002 | 2917 | — | 3256 | — | — | |||||||||||
Indoor unit | S-60PU2E5B | S-71PU2E5B | S-100PU2E5B | S-125PU2E5B | S-100PU2E5B | S-125PU2E5B | S-140PU2E5B | ||||||||||||
Indoor air flow (Hi) | m³/min | 21,00 | 22,00 | 36,00 | 37,00 | 36,00 | 37,00 | 38,00 | |||||||||||
Indoor air flow (Med) | m³/min | 16,00 | 16,00 | 26,00 | 27,00 | 26,00 | 27,00 | 29,00 | |||||||||||
Indoor air flow (Lo) | m³/min | 13,00 | 13,00 | 18,00 | 19,00 | 18,00 | 19,00 | 20,00 | |||||||||||
Indoor sound pressure (Hi) (5) | dB(A) | 36 | 37 | 45 | 46 | 45 | 46 | 47 | |||||||||||
Indoor sound pressure (Med) (5) | dB(A) | 31 | 31 | 38 | 39 | 38 | 39 | 40 | |||||||||||
Indoor sound pressure (Lo) (5) | dB(A) | 28 | 28 | 32 | 33 | 32 | 33 | 34 | |||||||||||
Indoor dimension (Height) | mm | 256 | 256 | 319 | 319 | 319 | 319 | 319 | |||||||||||
Indoor dimension (Width) | mm | 840 | 840 | 840 | 840 | 840 | 840 | 840 | |||||||||||
Indoor dimension (Depth) | mm | 840 | 840 | 840 | 840 | 840 | 840 | 840 | |||||||||||
Panel dimension (Height) | mm | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | |||||||||||
Panel dimension (Depth) | mm | 950 | 950 | 950 | 950 | 950 | 950 | 950 | |||||||||||
Indoor net weight | kg | 20 | 20 | 25 | 25 | 25 | 25 | 25 | |||||||||||
Panel net weight | kg | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |||||||||||
nanoe X Generator | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | ||||||||||||
Outdoor unit | U-60PEY2E5 | U-71PEY2E5 | U-100PEY1E5 | U-125PEY1E5 | U-100PEY1E8 | U-125PEY1E8 | U-140PEY1E8 | ||||||||||||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |||||||||||
Outdoor recommended fuse | A | 30 | 16 | 16 | 16 | ||||||||||||||
Outdoor connection indoor / outdoor | mm² | 6,0 | 2,5 | 2,5 | 2,5 | ||||||||||||||
Current in cooling (1p 220V / 3p 380) | A | 8,00 | 10,70 | 14,80 | 18,80 | 5,00 | 6,20 | 6,75 | |||||||||||
Current in cooling (1p 230V / 3p 400) | A | 7,60 | 10,30 | 14,20 | 18,00 | 4,75 | 5,90 | 6,40 | |||||||||||
Current in cooling (1p 240V / 3p 415) | A | 7,30 | 9,85 | 13,60 | 17,20 | 4,60 | 5,70 | 6,20 | |||||||||||
Current in heating (1p 220V / 3p 380) | A | 7,05 | 8,50 | 11,00 | 14,30 | 3,80 | 4,75 | 5,25 | |||||||||||
Current in heating (1p 230V / 3p 400) | A | 6,75 | 8,10 | 10,60 | 13,60 | 3,60 | 4,50 | 5,00 | |||||||||||
Current in heating (1p 240V / 3p 415) | A | 6,45 | 7,80 | 10,20 | 13,10 | 3,50 | 4,35 | 4,80 | |||||||||||
Outdoor air flow (Cool) | m³/min | 38 | 44 | 110 | 80 | 76 | 80 | 135 | |||||||||||
Outdoor air flow (Heat) | m³/min | 41 | 41 | 95 | 73 | 67 | 73 | 120 | |||||||||||
Outdoor sound pressure (Cool -Hi) | dB(A) | 46 | 49 | 52 | 56 | 54 | 56 | 54 | |||||||||||
Outdoor sound pressure (Heat -Hi) | dB(A) | 48 | 49 | 52 | 56 | 54 | 56 | 53 | |||||||||||
Outdoor dimension (Height) | mm | 619 | 619 | 996 | 996 | 996 | 996 | 1416 | |||||||||||
Outdoor dimension (Width) | mm | 799 | 799 | 940 | 940 | 940 | 940 | 940 | |||||||||||
Outdoor dimension (Depth) | mm | 299 | 299 | 340 | 340 | 340 | 340 | 340 | |||||||||||
Outdoor net weight | kg | 40 | 40 | 73 | 85 | 73 | 85 | 98 | |||||||||||
Pipe diameter (Liquid) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | |||||||||||
Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | |||||||||||
Pipe length range | m | 3 ~ 40 | 3 ~ 40 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | |||||||||||
Elevation difference (in/out) (5) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |||||||||||
Pipe length for additional gas | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |||||||||||
Additional gas amount | g/m | 40 | 40 | 50 | 50 | 50 | 50 | 50 | |||||||||||
Refrigerant (R410A) / CO2 Eq. | kg / T | 1,95 / 4,0716 | 1,95 / 4,0716 | 2,60 / 5,4288 | 3,20 / 6,6816 | 2,60 / 5,4288 | 3,20 / 6,6816 | 3,40 / 7,0992 | |||||||||||
Operating range (Cool - Min) | °C | -10 | -10 | -10 | -10 | -10 | -10 | -10 | |||||||||||
Operating range (Cool - Max) | °C | +43 | +43 | +43 | +43 | +43 | +43 | +43 | |||||||||||
Operating range (Heat - Min) | °C | -15 | -15 | -15 | -15 | -15 | -15 | -15 | |||||||||||
Operating range (Heat - Max) | °C | +24 | +24 | +24 | +24 | +24 | +24 | +24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.