Unité murale UZ super-compacte Inverter

Les unités murales de la gamme UZ sont compactes, silencieuses et de haute qualité.

Découvrez la dernière génération de systèmes d’air conditionné

La climatisation de demain

Caractéristiques

Voir tout
UZ super-compact • R32
2.5 kW
Kit KIT-UZ25-WKE
Cooling capacity (Nominal) kW 2,50
Cooling capacity (Min) kW 0,85
Cooling capacity (Max) kW 3,00
EER (Nominal) (1) W/W 3,68
EER (Min) (1) W/W 4,05
EER (Max) (1) W/W 3,33
SEER (2) 6,20 A++
Pdesign (cooling) kW 2,50
Input power cooling (Nominal) kW 0,68
Input power cooling (Min) kW 0,21
Input power cooling (Max) kW 0,90
Annual energy consumption cooling (3) kWh/a 141,00
Heating capacity (Nominal) kW 3,00
Heating capacity (Min) kW 0,80
Heating capacity (Max) kW 3,50
Heating capacity at -7°C kW 2,08
COP (Nominal) (1) W/W 4,05
COP (Min) (1) W/W 4,21
COP (Max) (1) W/W 3,47
SCOP (2) 4,10 A+
Pdesign at -10°C kW 1,90
Input power heating (Nominal) kW 0,74
Input power heating (Min) kW 0,19
Input power heating (Max) kW 1,01
Annual energy consumption heating (3) kWh/a 649
Indoor unit CS-UZ25WKE
Indoor power source V 230
Indoor recommended fuse A 16
Indoor connection indoor / outdoor mm² 4 x 1,5
Indoor air flow (Cool) m³/min 10,5
Indoor air flow (Heat) m³/min 11,1
Moisture removal volume L/h 1,5
Indoor sound pressure (Cool -Hi) (4) dB(A) 37
Indoor sound pressure (Cool -Hi) (4) dB(A) 37
Indoor sound pressure (Cool -Lo) (4) dB(A) 26
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 20
Indoor sound pressure (Heat -Hi) (4) dB(A) 37
Indoor sound pressure (Heat -Lo) (4) dB(A) 27
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 24
Indoor dimension (Height) mm 290
Indoor dimension (Width) mm 779
Indoor dimension (Depth) mm 209
Indoor net weight kg 8
Outdoor unit CU-UZ25WKE
Outdoor air flow (Cool) m³/min 30,4
Outdoor air flow (Heat) m³/min 30,4
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Outdoor sound pressure (Heat -Hi) (4) dB(A) 49
Outdoor dimension (Height) (5) mm 542
Outdoor dimension (Width) (5) mm 780
Outdoor dimension (Depth) (5) mm 289
Outdoor net weight kg 24
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 15
Elevation difference (in/out) (6) m 15
Pipe length for additional gas m 7,5
Additional gas amount g/m 10
Refrigerant (R32) / CO2 Eq. kg / T 0,54 / 0,365
Operating range (Cool - Min) °C -10
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

(1) Le calcul des coefficients EER et COP est conforme à la norme européenne EN 14511.
(2) Label énergétique allant de A+++ à D
(3) La consommation énergétique annuelle est calculée conformément à la directive UE/626/2011.
(4) Le niveau de pression sonore de l’unité intérieure indique la valeur pour une position à 1 m en face du corps principal et à 0,8 m en dessous de l’unité. Pour une unité extérieure, 1 mètre en face et 1 mètre sur le côté arrière du corps principal. La pression sonore est mesurée conformément à la norme JIS C 9612. Q-Faible : mode silencieux. Faible : vitesse de consigne minimale du ventilateur.
(5) Ajouter 70 mm pour l’orifice des tuyauteries.
(6) Lors de l’installation de l’unité extérieure à une position plus élevée que l’unité intérieure.

Accessoires