Floor Console Inverter+ • R32

Previous capacity Next capacity

2.5kW

KIT-Z25-CFE (CS-Z25CFEAW + CU-Z25CBEA)

Floor console. Efficient comfort and cleaner air all year round 

Delivering efficient heating and cooling, the floor console enhances indoor comfort with ultra-quiet operation and cleaner air thanks to nanoe™ X technology. With Wi‑Fi built-in, it offers flexible, remote control. 

Specifications

See all
Floor Console Inverter+ • R32
2.5 kW
Cooling capacity (Min) kW 0,85
Input power heating (Min) kW 0,24
COP (Max) (1) W/W 3,70
COP (Min) (1) W/W 3,54
Heating capacity (Max) kW 5,00
Heating capacity (Min) kW 0,85
Input power cooling (Max) kW 0,90
Input power cooling (Min) kW 0,24
EER (Max) (1) W/W 3,78
EER (Min) (1) W/W 3,54
Cooling capacity (Max) kW 3,40
Input power heating (Max) kW 1,35
Operating range (Heat - Max) °C +24
Operating range (Heat - Min) °C -15
Operating range (Cool - Max) °C +43
Elevation difference (in/out) (6) m 15
Outdoor dimension (Depth) (5) mm 289
Outdoor dimension (Width) (5) mm 780
Outdoor dimension (Height) (5) mm 542
Outdoor sound pressure (Heat -Hi) (4) dB(A) 47
Outdoor unit CU-Z25CBEA
nanoe X Generator Mark 3
Outdoor connection indoor / outdoor mm² 4x1,5
Outdoor recommended fuse A 16
Outdoor air flow (Heat) m³/min 27,2
Outdoor air flow (Cool) m³/min 28,7
Indoor unit CS-Z25CFEAW
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 19
Indoor sound pressure (Heat -Lo) (4) dB(A) 25
Indoor sound pressure (Heat -Hi) (4) dB(A) 38
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 20
Indoor sound pressure (Cool -Lo) (4) dB(A) 25
Moisture removal volume L/h 1,5
Indoor air flow (Heat) m³/min 10,0
Indoor air flow (Cool) m³/min 9,6
Annual energy consumption heating (3) kWh/a 822
Annual energy consumption cooling (3) kWh/a 111
Input power cooling (Nominal) kW 0,52
Pdesign (cooling) kW 2,50
SEER (2) 7,90 A++
Outdoor net weight kg 32
Outdoor sound pressure (Cool -Hi) (4) dB(A) 46
Indoor net weight kg 13
Indoor dimension (Height) mm 600
Indoor sound pressure (Cool -Hi) (4) dB(A) 38
SCOP (2) 4,60 A++
Pipe length range m 3 ~ 20
Heating capacity at -7°C kW 2,88
Kit KIT-Z25-CFE
Additional gas amount g/m 10
Pipe length for additional gas m 7,5
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Indoor dimension (Depth) mm 207
Indoor dimension (Width) mm 750
Refrigerant (R32) / CO2 Eq. kg / T 0,88 / 0,59
EER (Nominal) (1) W/W 4,81
COP (Nominal) (1) W/W 4,47
Outdoor power source V 230
Heating capacity (Nominal) kW 3,40
Cooling capacity (Nominal) kW 2,50
Operating range (Cool - Min) °C -10
Input power heating (Nominal) kW 0,76
Pdesign at -10°C kW 2,70

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of a position 1 m in front of the main body and 1 m above floor. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.