Stand-alone outdoor M Series 1 phase – 3 phase · R290

Aquarea High Performance M Series, the next generation of heat pumps with R290 

Combining flexible system design, quiet operation and up to 75°C water flow, the Aquarea High Performance M Series offers a reliable, high‑quality heat pump solution for new‑build and retrofit applications.

• R290 refrigerant with GWP of just 0,02

A+++ in heating at 35°C

Up to 75°C water outlet temperature, even at outdoor temperatures down to -15°C

Reliable operation with Panasonic compressor, down to -25°C outdoor temperature

Comfort Cloud App and Aquarea Service Cloud included as standard

Flexible integration into heating installations

Flexible installation without an indoor unit

Choice of remote controller or control module for advanced functionality


*Control options available separately. See combination table for compatible combinations.

Specifications

See all
Stand-alone outdoor M Series 1 phase – 3 phase · R290 SINGLE PHASE THREE PHASE
12.00 kW 16.00 kW 9.00 kW 12.00 kW 16.00 kW
Outdoor unit WH-WDG12ME5 WH-WDG16ME5 WH-WDG09ME8 WH-WDG12ME8 WH-WDG16ME8
Heating capacity (A +7°C, W 35°C) kW 12,00 16,00 9,00 12,00 16,00
COP (A +7°C, W 35°C) 4,88 4,65 5,10 4,88 4,65
Heating capacity (A +7°C, W 55°C) kW 12,00 14,70 9,00 12,00 14,70
COP (A +7°C, W 55°C) 3,06 3,00 3,10 3,06 3,00
Heating capacity (A +2°C, W 35°C) kW 12,00 13,00 9,00 12,00 13,00
COP (A +2°C, W 35°C) 3,46 3,30 3,81 3,46 3,30
Heating capacity (A +2°C, W 55°C) kW 12,00 12,00 9,00 12,00 12,00
COP (A +2°C, W 55°C) 2,27 2,27 2,52 2,27 2,27
Heating capacity (A -7°C, W 35°C) kW 10,50 11,70 9,00 10,50 11,70
COP (A -7°C, W 35°C) 3,00 2,63 3,16 3,00 2,63
Heating capacity (A -7°C, W 55°C) kW 10,00 10,80 9,00 10,00 10,80
COP (A -7°C, W 55°C) 1,97 1,90 2,07 1,97 1,90
Cooling capacity (A 35°C, W 7°C) kW 9,00 9,00 9,00 9,00 9,00
EER (A 35°C, W 7°C) 3,61 3,61 3,61 3,61 3,61
Cooling capacity (A 35°C, W 18°C) kW 9,00 9,00 9,00 9,00 9,00
EER (A 35°C, W 18°C) 5,26 5,26 5,26 5,26 5,26
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,65 / 3,50 4,58 / 3,58 4,84 / 3,57 4,65 / 3,58 4,58 / 3,58
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 183 / 137 180 / 140 191 / 140 183 / 140 180 / 140
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,34 6,20 / 4,34 6,01 / 4,17 6,20 / 4,34 6,20 / 4,34
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 171 245 / 171 237 / 164 245 / 171 245 / 171
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,35 / 3,26 4,30 / 3,26 4,23 / 3,12 4,35 / 3,26 4,30 / 3,26
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 171 / 127 169 / 127 166 / 122 171 / 127 169 / 127
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A+ A++ / A++ A++ / A++
Outdoor sound power (Heat) (2) dB(A) 55 58 54 55 58
Outdoor dimension (Height) mm 1.520 1.520 1.520 1.520 1.520
Outdoor dimension (Width) mm 1.200 1.200 1.200 1.200 1.200
Outdoor dimension (Depth) mm 370 370 370 370 370
Outdoor net weight kg 147 147 151 151 151
A class pump (Number of speeds) Variable speed Variable speed Variable speed Variable speed Variable speed
A class pump (Input power Min) W 30 30 30 30 30
A class pump (Input power Max) W 175 175 175 175 175
Heating water flow (∆T=5 K. 35°C) L/min 34,4 45,9 25,8 34,4 45,9
Refrigerant (R290) / CO2 Eq. (3) kg / T 1,58 / 0,00003 1,58 / 0,00003 1,58 / 0,00003 1,58 / 0,00003 1,58 / 0,00003
Operation range - Outdoor ambient (Heat) °C -25 ~ +35 -25 ~ +35 -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20
Indoor unit WH-CME5 WH-CME5 WH-CME8 WH-CME8 WH-CME8
Indoor dimension (Height) mm 454 454 454 454 454
Indoor dimension (Width) mm 520 520 520 520 520
Indoor dimension (Depth) mm 116 116 116 116 116
Indoor net weight kg 7 7 7 7 7
Pipe length range standard m 5 5 5 5 5
Pipe length range maximum m 30 30 30 30 30
Elevation difference (in/out) m 30 30 30 30 30
(1) Scale from A+++ to D.
(2) Sound power level in accordance with EN 12102 under conditions of the EN 14825 (part load).
(3) WH-WDG models are hermetically sealed.
(4) Water outlet up to 75°C above -15°C outdoor. Between outdoor ambient -15°C and -25°C, the water outlet temperature gradually decreases from 75°C to 55°C.
(5) Check local regulations.
*EER and COP calculation is based in accordance with EN 14511.
**This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.