12.5 kW. Stropna jedinica PACi Standard • R410A

KIT-125PTY2E8D (S-125PT2E5B + U-125PEY1E8)

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Ova linija proizvoda za stropnu ugradnju ima istosmjerni motor ventilatora za veću učinkovitost i smanjene razine buke.

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Sve su jedinice iste visine i dubine kako bi se postigao ujednačeni izgled pri mješovitoj ugradnji. Omogućeno je ubacivanje svježeg zraka radi poboljšanja kvalitete zraka.

  • Široki raspon raspodjele zraka za velike prostorije
  • Vodoravni protok zraka postiže maksimalno 9,5 m
  • Priključak za svježi zrak dostupan na jedinici
  • Tanak dizajn visine 235 m odgovara uskim prostorima
  • Tihi način rada
  • Jednostavna aplikacija za podršku sustava datanavi s daljinskim upravljačem (CZ-RTC5B)
  • Dvostruke, trostruke i duplo-dvostruke split mogućnosti
  • Jednostavno spajanje i upravljanje vanjskim ventilatorom ili ventilacijom s povratom energije korištenjem priključka PAW-FDC na tiskanoj pločici unutarnje jedinice. Vanjskim se uređajem može upravljati daljinskim upravljačem Panasonic unutarnje jedinice

Specifikacije

Prikaži sve
Stropna jedinica PACi Standard • R410A Trofazno
12.5 kW
EER (Nominal) (1) W/W 3,01 (4,22 - 2,62) B
COP (Nominal) (1) W/W 3,85 (4,66 - 3,41) A
Kit KIT-125PTY2E8D
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,50
Cooling capacity (Min) kW 3,80
Cooling capacity (Max) kW 13,50
EER (Nominal) (1) W/W 3,01
EER (Min) (1) W/W 4,22
EER (Max) (1) W/W 2,62
SEER (2) 5,24
Pdesign (cooling) kW 12,50
Input power cooling (Nominal) kW 4,15
Input power cooling (Min) kW 0,90
Input power cooling (Max) kW 5,16
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 12,50
Heating capacity (Min) kW 3,40
Heating capacity (Max) kW 15,00
Heating capacity at -7°C (4) kW 10,97
Heating capacity at -15°C (4) kW 9,03
COP (Nominal) (1) W/W 3,85
COP (Min) (1) W/W 4,66
COP (Max) (1) W/W 3,41
SCOP (2) 3,58
Pdesign at -10°C kW 12,50
Input power heating (Nominal) kW 3,25
Input power heating (Min) kW 0,73
Input power heating (Max) kW 4,40
Annual energy consumption heating (3) kWh/a
Indoor unit S-125PT2E5B
Indoor air flow (Hi) m³/min 34,00
Indoor air flow (Med) m³/min 28,00
Indoor air flow (Lo) m³/min 24,00
Indoor sound pressure (Hi) (5) dB(A) 46
Indoor sound pressure (Med) (5) dB(A) 40
Indoor sound pressure (Lo) (5) dB(A) 36
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
Outdoor unit U-125PEY1E8
Outdoor power source V 380 - 400 - 415
Outdoor recommended fuse A 16
Outdoor connection indoor / outdoor mm² 2,5
Current in cooling (1p 220V / 3p 380) A 6,50
Current in cooling (1p 230V / 3p 400) A 6,20
Current in cooling (1p 240V / 3p 415) A 6,00
Current in heating (1p 220V / 3p 380) A 5,10
Current in heating (1p 230V / 3p 400) A 4,80
Current in heating (1p 240V / 3p 415) A 4,65
Outdoor air flow (Cool) m³/min 80
Outdoor air flow (Heat) m³/min 73
Outdoor sound pressure (Cool -Hi) dB(A) 56
Outdoor sound pressure (Heat -Hi) dB(A) 56
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 85
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 50
Refrigerant (R410A) / CO2 Eq. kg / T 3,20 / 6,6816
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

(1) Vrijednosti EER i COP izračunate su u skladu s normom EN14511.
(2) Skala energetske oznake od A+++ do D. Za modele ispod 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/626/2011. Za modele iznad 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/2281/2016.
(3) Godišnja potrošnja energije izračunata je u skladu s odredbom EU/626/2011.
(4) Kapacitet grijanja izračunat je uključujući faktor ispravke za odleđivanje.
(5) Zvučni tlak jedinica prikazuje vrijednost izmjerenu na položaju 1 metar ispred glavnog tijela i 1 metar ispod jedinice. Zvučni tlak mjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(6) Prilikom ugradnje vanjske jedinice na položaj viši od unutarnje jedinice.
* Preporučeni osigurač za unutarnju jedinicu 3 A.