6.0 kW. Stropna jedinica PACi Standard • R410A

KIT-60PTY2E5D (S-60PT2E5B + U-60PEY2E5)

Prijašnji kapacitet Novi kapacitet

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Ova linija proizvoda za stropnu ugradnju ima istosmjerni motor ventilatora za veću učinkovitost i smanjene razine buke.

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Sve su jedinice iste visine i dubine kako bi se postigao ujednačeni izgled pri mješovitoj ugradnji. Omogućeno je ubacivanje svježeg zraka radi poboljšanja kvalitete zraka.

  • Široki raspon raspodjele zraka za velike prostorije
  • Vodoravni protok zraka postiže maksimalno 9,5 m
  • Priključak za svježi zrak dostupan na jedinici
  • Tanak dizajn visine 235 m odgovara uskim prostorima
  • Tihi način rada
  • Jednostavna aplikacija za podršku sustava datanavi s daljinskim upravljačem (CZ-RTC5B)
  • Dvostruke, trostruke i duplo-dvostruke split mogućnosti
  • Jednostavno spajanje i upravljanje vanjskim ventilatorom ili ventilacijom s povratom energije korištenjem priključka PAW-FDC na tiskanoj pločici unutarnje jedinice. Vanjskim se uređajem može upravljati daljinskim upravljačem Panasonic unutarnje jedinice

Specifikacije

Prikaži sve
Stropna jedinica PACi Standard • R410A Jednofazno
6.0 kW
EER (Nominal) (1) W/W 3,68 (8,00 - 3,16) A
COP (Nominal) (1) W/W 4,35 (9,00 - 4,38) A
Kit KIT-60PTY2E5D
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,00
Cooling capacity (Min) kW 2,00
Cooling capacity (Max) kW 7,10
EER (Nominal) (1) W/W 3,68
EER (Min) (1) W/W 8,00
EER (Max) (1) W/W 3,16
SEER (2) 6,70 A++
Pdesign (cooling) kW 6,00
Input power cooling (Nominal) kW 1,63
Input power cooling (Min) kW 0,25
Input power cooling (Max) kW 2,25
Annual energy consumption cooling (3) kWh/a 313
Heating capacity (Nominal) kW 6,00
Heating capacity (Min) kW 1,80
Heating capacity (Max) kW 7,00
Heating capacity at -7°C (4) kW
Heating capacity at -15°C (4) kW
COP (Nominal) (1) W/W 4,35
COP (Min) (1) W/W 9,00
COP (Max) (1) W/W 4,38
SCOP (2) 4,00 A+
Pdesign at -10°C kW 6,00
Input power heating (Nominal) kW 1,38
Input power heating (Min) kW 0,20
Input power heating (Max) kW 1,60
Annual energy consumption heating (3) kWh/a 2100
Indoor unit S-60PT2E5B
Indoor air flow (Hi) m³/min 20,00
Indoor air flow (Med) m³/min 17,00
Indoor air flow (Lo) m³/min 14,50
Indoor sound pressure (Hi) (5) dB(A) 38
Indoor sound pressure (Med) (5) dB(A) 34
Indoor sound pressure (Lo) (5) dB(A) 30
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1275
Indoor dimension (Depth) mm 690
Indoor net weight kg 33
Outdoor unit U-60PEY2E5
Outdoor power source V 220 - 230 - 240
Outdoor recommended fuse A
Outdoor connection indoor / outdoor mm²
Current in cooling (1p 220V / 3p 380) A 8,00
Current in cooling (1p 230V / 3p 400) A 7,60
Current in cooling (1p 240V / 3p 415) A 7,30
Current in heating (1p 220V / 3p 380) A 6,70
Current in heating (1p 230V / 3p 400) A 6,45
Current in heating (1p 240V / 3p 415) A 6,15
Outdoor air flow (Cool) m³/min 38
Outdoor air flow (Heat) m³/min 41
Outdoor sound pressure (Cool -Hi) dB(A) 46
Outdoor sound pressure (Heat -Hi) dB(A) 48
Outdoor dimension (Height) mm 619
Outdoor dimension (Width) mm 799
Outdoor dimension (Depth) mm 299
Outdoor net weight kg 40
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R410A) / CO2 Eq. kg / T 1,95 / 4,0716
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

(1) Vrijednosti EER i COP izračunate su u skladu s normom EN14511.
(2) Skala energetske oznake od A+++ do D. Za modele ispod 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/626/2011. Za modele iznad 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/2281/2016.
(3) Godišnja potrošnja energije izračunata je u skladu s odredbom EU/626/2011.
(4) Kapacitet grijanja izračunat je uključujući faktor ispravke za odleđivanje.
(5) Zvučni tlak jedinica prikazuje vrijednost izmjerenu na položaju 1 metar ispred glavnog tijela i 1 metar ispod jedinice. Zvučni tlak mjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(6) Prilikom ugradnje vanjske jedinice na položaj viši od unutarnje jedinice.
* Preporučeni osigurač za unutarnju jedinicu 3 A.

Dodatni proizvodi

Studije slučaja Pogledajte sve projekte

Novosti