Jedinica s visokim statičkim tlakom za skrivenu ugradnju BIG PACi od 20,0 – 25,0 kW • R32

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Big PACi s plinom R32 predstavljen je s potpuno obnovljenom unutarnjom jedinicom, nudeći primjenu u vodenim sustavima putem PACi izmjenjivača topline vode.

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Big PACi korisno je i cjenovno prihvatljivo rješenje za projekte male i srednje veličine te je u ponudi i s VRF sustavom.
<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Kompaktno i lagano unutarnje kućište za održavanje visoke učinkovitosti dizajnirano je tako da se može odvojiti za jednostavno postavljanje cijevi u ograničenom uskom prostoru.

  • Visoka učinkovitost uz kompaktno unutarnje kućište, 16 kg laganije od uobičajenog modela (10 toplinskih pumpi)
  • Dizajn za skrivenu ugradnju s mogućnošću odvajanja za jednostavno i fleksibilno postavljanje cijevi
  • Bolja regulacija pri djelomičnom opterećenju uz Panasonicov kompresor
  • Bluefin antikorozivni premaz
  • Kompatibilnost s PACi izmjenjivačem topline vode
  • Kompatibilnost s upravljanjem za rad u Panasonicovu oblaku
  • 0 – 10 V upravljanje opterećenjem

Specifikacije

Prikaži sve
Jedinica s visokim statičkim tlakom za skrivenu ugradnju BIG PACi od 20,0 – 25,0 kW • R32 Trofazno
20 kW 25 kW
EER (Nominal) (1) W/W 3,22 3,11
COP (Nominal) (1) W/W 3,61 3,41
Refrigerant (R32) / CO2 Eq. kg / T 4,20 / 2,835 5,20 / 3,51
Kit KIT-200PE3ZH8 KIT-250PE3ZH8
Remote controller CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 19,5 23,2
Cooling capacity (Min) kW 5,7 6,1
Cooling capacity (Max) kW 21 27
EER (1) W/W 3,22 3,11
SEER (2) 5,3 4,9
Pdesign (cooling) kW 19,5 23,2
Input power cooling kW 6,06 7,46
Heating capacity (Nominal) kW 22,4 28,0
Heating capacity (Min) kW 5,0 5,5
Heating capacity (Max) kW 25,0 29,0
COP (1) W/W 3,61 3,41
SCOP (2) 3,6 3,6
Pdesign at -10°C kW 17,0 20,0
Input power heating kW 6,21 8,21
Indoor unit S-200PE3E5B S-250PE3E5B
Indoor power supply (Voltage) V 220 - 230 - 240 220 - 230 - 240
Indoor power supply (Phase) Single phase Single phase
Indoor power supply (Frequency) Hz 50 50
External static pressure at shipment (adjustable) Pa 75 (3) - 120 - 180 75 (3) - 130 - 200
Indoor air flow (Hi) m³/min 72 84
Indoor air flow (Med) m³/min 63 72
Indoor air flow (Lo) m³/min 53 59
Indoor sound pressure (Med) (4) dB(A) 44 45
Indoor sound pressure (Lo) (4) dB(A) 41 42
Indoor dimension (Height) mm 486 486
Indoor dimension (Width) mm 1456 1456
Indoor dimension (Depth) mm 916 916
Indoor net weight kg 86 88
Outdoor unit U-200PZH2E8 U-250PZH2E8
Power supply (Voltage) V 380 - 400 - 415 380 - 400 - 415
Power supply (Phase) Three phase Three phase
Power supply (Frequency) Hz 50 50
Outdoor recommended fuse A 30 30
Outdoor air flow (Cool) m³/min 164 160
Outdoor air flow (Heat) m³/min 164 160
Outdoor sound pressure (Cool -Hi) dB(A) 59 59
Outdoor sound pressure (Heat -Hi) dB(A) 61 63
Outdoor sound power (Cool -Hi) dB(A) 77 78
Outdoor sound power (Heat -Hi) dB(A) 79 82
Outdoor dimension (Height) (5) mm 1500 1500
Outdoor dimension (Width) (5) mm 980 980
Outdoor dimension (Depth) (5) mm 370 370
Outdoor net weight kg 117 128
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 1/2 (12,70)
Pipe diameter (Gas) Inch (mm) 1 (25,40) 1 (25,40)
Pipe length range m 5 ~ 90 5 ~ 90
Elevation difference (in/out) (6) m 30 30
Pipe length for additional gas m 30 30
Additional gas amount g/m 60 80
Refrigerant (R32) / CO2 Eq. kg / T 4,20 / 2,835 5,20 / 3,51
Operating range (Cool - Min) °C -15 -15
Operating range (Cool - Max) °C 46 46
Operating range (Heat - Min) °C -20 -20
Operating range (Heat - Max) °C 24 24

(1) Vrijednosti EER i COP izračunate su u skladu s normom EN14511.
(2) Za modele ispod 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/626/2011. Za modele iznad 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/2281/2016.
(3) Tvornička postavka.
(4) Zvučni tlak jedinica prikazuje vrijednost izmjerenu na položaju 1,5 m ispod jedinice. Zvučni tlak mjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(5) Za unutarnju jedinicu dodajte 100 mm, a za vanjsku 70 mm za priključak cijevi.
(6) Prilikom ugradnje vanjske jedinice na položaj viši od unutarnje jedinice.
* Filtar nije uključen.

Dodatni proizvodi

Studije slučaja Pogledajte sve projekte

Novosti