2-Pipe ECOi EX ME2 series
8kW
U-8ME2E8
A VRF system delivering energy-saving performance, powerful operation, reliability and comfort surpassing anything previously possible
It represents a true paradigm shift in air conditioning solutions.
VRF with outstanding energy-saving performance and powerful operation SEER 7,6 (18HP model).
- New twin rotary inverter compressor
- High performance at extreme conditions
- Outstanding efficiency and comfort
- Extraordinary partial load and SEER/SCOP
- SEER and SCOP following to EN-14825
- Oil recovery intelligent control
- Top comfort
- Superior flexibility
- Bluefin full line up EX
- Extremely high capacity at -20°C and unique heating capacity at -25°C
- Smooth exhaust flow by new bell-mouth
Best efficiency ECOi Series
Ypač tinka prekybos įstaigoms, viešbučiams ir biurams
„Panasonic ECOi“ sertifikuota „Eurovent“
„Eurovent“ sertifikatas patvirtina šildymo ir vėsinimo sistemų našumo rodiklius pagal Europos standartus. Šie duomenys užtikrina visišką gaminių našumo informacijos skaidrumą tiek klientų, tiek specialistų naudai.
„Panasonic ECOi“ sertifikuota „Eurovent“
„Eurovent“ sertifikatas patvirtina šildymo ir vėsinimo sistemų našumo rodiklius pagal Europos standartus. Šie duomenys užtikrina visišką gaminių našumo informacijos skaidrumą tiek klientų, tiek specialistų naudai.
Specifikacijos
| 2-Pipe ECOi EX ME2 series | |||
|---|---|---|---|
| 8 kW | |||
| EER (Nominal) (1) | W/W | 4,70 | |
| COP (Nominal) (1) | W/W | 5,13 | |
| Operating range (Cool - Min) | °C | -10 ~ +52 | |
| Operating range (Cool - Min) | °C | -10 ~ +52 | |
| Cooling capacity (Nominal) | kW | 22,4 | |
| Cooling capacity (Nominal) | kW | 22,4 | |
| Heating capacity (Nominal) | kW | 25,0 | |
| Outdoor power source | V | 380 / 400 / 415 | |
| Indoor sound pressure (Heat) | dB(A) | 54,0 | |
| Dimensions | 1.842 x 770 x 1.000 | ||
| Net weight | kg | 210 | |
| Refrigerant (R410A) / CO2 Eq. | kg / T | 5,6 / 11,6928 | |
1) EER and COP calculation is based in accordance to EN14511.
2) SEER/SCOP is calculated based on the seasonal space cooling/heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.
3) Piping diameter under 90m for ultimate indoor unit / over 90m for ultimate indoor unit (if the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
4) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.