##Delete: BIG PACi High Static Pressure Hide Away 20,0-25,0kW • R410A

Big PACi has been introduced with full renewal of its indoor unit, offering hydronic application by PACi Water Heat Exchanger.
Big PACi is useful and cost saving solution for small and mid size of projects, can be offered also with VRF system.
Compact and light indoor body keeping the high efficiency is split-able design for easy piping work at limited narrow space.

  • Highly efficient with compact indoor body, -16kg lighter than conventional model (10 HP)
  • Split-able Hide Away indoor design for easy & flexible piping work
  • Better partial load control with Panasonic compressor
  • Bluefin anti-rust coating
  • PACi Water Heat Exchanger compatible
  • Panasonic cloud control compatible
  • 0-10V demand control

Technische Daten

Alles anzeigen
##Delete: BIG PACi High Static Pressure Hide Away 20,0-25,0kW • R410A Dreiphasig
20 kW 25 kW 200 kW 250 kW
Kit KIT-200PE3E5D KIT-250PE3E5D
Remote controller CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 19,50 23,20
Cooling capacity (Min) kW 5,40 6,30
Cooling capacity (Max) kW 21,00 27,00
EER (1) W/W 3,10 3,00
SEER (2) 5,11 4,81
Pdesign (cooling) kW 19,50 23,20
Input power cooling kW 6,29 7,73
Heating capacity (Nominal) kW 22,40 28,00
Heating capacity (Min) kW 5,60 7,10
Heating capacity (Max) kW 25,00 29,00
COP (1) W/W 3,60 3,39
SCOP (2) 3,57 3,60
Pdesign at -10°C kW 17,00 20,00
Input power heating kW 6,22 8,27
Indoor unit S-200PE3E5B S-250PE3E5B
Indoor power supply (Voltage) V 220 - 230 - 240 220 - 230 - 240
Indoor power supply (Phase) Single phase Single phase
Indoor power supply (Frequency) Hz 50 50
External static pressure at shipment (with booster cable) (3) Pa 75 - 120 - 180 75 - 130 - 200
Indoor air flow (Hi) m³/min 72 84
Indoor air flow (Med) m³/min 63 72
Indoor air flow (Lo) m³/min 53 59
Indoor sound pressure (Med) (4) dB(A) 44 45
Indoor sound pressure (Lo) (4) dB(A) 41 42
Indoor dimension (Height) mm 486 486
Indoor dimension (Width) mm 1456 1456
Indoor dimension (Depth) mm 916 916
Indoor net weight kg 86 88
Outdoor unit U-200PE2E8A U-250PE2E8A
Power supply (Voltage) V 380 - 400 - 415 380 - 400 - 415
Power supply (Phase) Three phase Three phase
Power supply (Frequency) Hz 50 50
Outdoor recommended fuse A 15 20
Outdoor air flow (Cool) m³/min 164 160
Outdoor air flow (Heat) m³/min 60 61
Outdoor sound pressure (Cool -Hi) dB(A) 62 63
Outdoor sound pressure (Heat -Hi) dB(A) 1500 1500
Outdoor dimension (Height) (5) mm 980 980
Outdoor dimension (Width) (5) mm 370 370
Outdoor dimension (Depth) (5) mm 127 138
Outdoor net weight kg 3/8 (9,52) 1/2 (12,70)
Pipe diameter (Liquid) Inch (mm) 1 (25,40) 1 (25,40)
Pipe diameter (Gas) Inch (mm) 5 5
Pipe length range m 120 120
Elevation difference (in/out) (6) m 30 30
Pipe length for additional gas m 30 30
Additional gas amount g/m 50 80
Refrigerant (R410A) / CO2 Eq. kg / T 5,60 / 11,6928 6,40 / 13,3632
Operating range (Cool - Min) °C -15 -15
Operating range (Cool - Max) °C +46 +46
Operating range (Heat - Min) °C -20 -20
Operating range (Heat - Max) °C +24 +24