Modelos
Etherea stylish and outstanding features.
Etherea with nanoe™ X technology: outstanding efficiency A+++, comfort (Super Quiet technology only 19 dB(A)) and healthy air combined in a breakthrough design.
- nanoe™ X, technology with the benefits of hydroxyl radicals, improve protection 24/7
- Built-in Wi-Fi Panasonic Comfort Cloud for internet control
- Compatible with voice control
- Super Quiet operation
- Infrared control Sky Controller
- Mild Dry Cooling: prevent a rapid decrease in room humidity
- Aerowings to control air draft direction
- More powerful airflow to quickly reach the desired temperature
- Wired control (Optional)
Uma gama de produtos concebidos para si
Descubra a última geração de sistemas de ar condicionado



Poupanças significativas e melhor bem-estar
Os nossos sistemas de ar condicionado produzem os níveis mais elevados de conforto com um custo energético bastante reduzido, criando um ar saudável livre de vírus, bactérias, pólen e odores.
Uma gama de produtos concebidos para si
Das soluções mais pequenas 1x1 às soluções mais completas 5x1, sejam quais forem as suas necessidades. A Panasonic consegue proporcionar-lhe a melhor solução para usufruir do melhor ambiente de climatização em sua casa.
Uma casa confortável durante todo o ano
Os nossos sistemas de ar condicionado oferecem-lhe a temperatura mais confortável ao longo do ano, aquecimento no inverno, climatização no verão e limpeza do ambiente durante todo o ano.
Poupanças significativas e melhor bem-estar
Os nossos sistemas de ar condicionado produzem os níveis mais elevados de conforto com um custo energético bastante reduzido, criando um ar saudável livre de vírus, bactérias, pólen e odores.
Uma gama de produtos concebidos para si
Das soluções mais pequenas 1x1 às soluções mais completas 5x1, sejam quais forem as suas necessidades. A Panasonic consegue proporcionar-lhe a melhor solução para usufruir do melhor ambiente de climatização em sua casa.
Uma casa confortável durante todo o ano
Os nossos sistemas de ar condicionado oferecem-lhe a temperatura mais confortável ao longo do ano, aquecimento no inverno, climatização no verão e limpeza do ambiente durante todo o ano.
Trazer o equilíbrio da natureza para dentro de casa
O ar condicionado liga-o ao futuro
Especificações
Etherea Inverter+ Silver • R32 | MONOFÁSICO | ||||||||
---|---|---|---|---|---|---|---|---|---|
2.1 kW | |||||||||
Kit | KIT-XZ20-VKE | ||||||||
Cooling capacity (Nominal) | kW | 2,05 | |||||||
Cooling capacity (Min) | kW | 0,75 | |||||||
Cooling capacity (Max) | kW | 2,40 | |||||||
EER (Nominal) (1) | W/W | 4,56 | |||||||
EER (Min) (1) | W/W | 3,13 | |||||||
EER (Max) (1) | W/W | 4,32 | |||||||
SEER (2) | 7,50 A++ | ||||||||
Pdesign (cooling) | kW | 2,10 | |||||||
Input power cooling (Nominal) | kW | 0,45 | |||||||
Input power cooling (Min) | kW | 0,24 | |||||||
Input power cooling (Max) | kW | 0,56 | |||||||
Annual energy consumption cooling (3) | kWh/a | 98,00 | |||||||
Heating capacity (Nominal) | kW | 2,80 | |||||||
Heating capacity (Min) | kW | 0,70 | |||||||
Heating capacity (Max) | kW | 4,00 | |||||||
Heating capacity at -7°C | kW | 2,38 | |||||||
COP (Nominal) (1) | W/W | 4,52 | |||||||
COP (Min) (1) | W/W | 3,89 | |||||||
COP (Max) (1) | W/W | 4,04 | |||||||
SCOP (2) | 4,70 A++ | ||||||||
Pdesign at -10°C | kW | 2,10 | |||||||
Input power heating (Nominal) | kW | 0,62 | |||||||
Input power heating (Min) | kW | 0,18 | |||||||
Input power heating (Max) | kW | 0,99 | |||||||
Annual energy consumption heating (3) | kWh/a | 626 | |||||||
Indoor unit | CS-XZ20VKEW | ||||||||
Indoor power source | V | 230 | |||||||
Indoor recommended fuse | A | 16 | |||||||
Indoor connection indoor / outdoor | mm² | 4 x 1,5 | |||||||
Indoor air flow (Cool) | m³/min | 9,9 | |||||||
Indoor air flow (Heat) | m³/min | 10,7 | |||||||
Moisture removal volume | L/h | 1,3 | |||||||
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 37 | |||||||
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 37 | |||||||
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 24 | |||||||
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 19 | |||||||
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 38 | |||||||
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 25 | |||||||
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 19 | |||||||
Indoor dimension (Height) | mm | 295 | |||||||
Indoor dimension (Width) | mm | 919 | |||||||
Indoor dimension (Depth) | mm | 194 | |||||||
Indoor net weight | kg | 9 | |||||||
nanoe X Generator | Mark 1 | ||||||||
Outdoor unit | CU-Z20VKE | ||||||||
Outdoor air flow (Cool) | m³/min | 26,9 | |||||||
Outdoor air flow (Heat) | m³/min | 24,1 | |||||||
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 45 | |||||||
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 45 | |||||||
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 46 | |||||||
Outdoor dimension (Height) (5) | mm | 542 | |||||||
Outdoor dimension (Width) (5) | mm | 780 | |||||||
Outdoor dimension (Depth) (5) | mm | 289 | |||||||
Outdoor net weight | kg | 27 | |||||||
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |||||||
Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | |||||||
Pipe length range | m | 3 ~ 15 | |||||||
Elevation difference (in/out) (6) | m | 15 | |||||||
Pipe length for additional gas | m | 7,5 | |||||||
Additional gas amount | g/m | 10 | |||||||
Refrigerant (R32) / CO2 Eq. | kg / T | 0,70 / 0,473 | |||||||
Operating range (Cool - Min) | °C | -10 | |||||||
Operating range (Cool - Min) | °C | -10 | |||||||
Operating range (Cool - Max) | °C | +43 | |||||||
Operating range (Heat - Min) | °C | -15 | |||||||
Operating range (Heat - Max) | °C | +24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.