Golvmodeller Inverter+ - R32

Tidigare kapacitet Nästa kapacitet

Ny luftvärmepump golvmodell

Med nytt nanoe™ X luftreningssystem: enastående effektivitet A++ och komfort med toppmodern design.



Upptäck den senaste generationen värmepumpsystem

Värmepumpen ansluter till framtiden

Vi hjälper dig att välja rätt Panasonic luftvärmepump för hemmet

Hur fungerar en luftvärmepump?

Naturens balans inomhus

Specifikationer

Visa alla
Golvmodeller Inverter+ - R32
2.50 kW
Maximum capacity kW 5,50
Reference CS-Z25UFEAW-1 + CU-Z25UFEA-1
Heating capacity (Nominal) kW 3,40
Heating capacity (Min) kW 0,85
Heating capacity (Max) kW 5,50
COP (1) W/W 4,59 
Heating capacity at -7°C (2) kW 3,80
COP at -7°C (1) W/W 2,53
Heating capacity at -15°C (2) kW 3,50
COP at -15°C (1) W/W 2,30
Heating capacity at -20°C (2) kW 2,90
COP at -20°C (1) W/W 1,96
Heating capacity at -25°C (2) kW 2,40
COP at -25°C (1) W/W 1,68
SCOP (3) 4,70 A++
SCOP tested by 3rd party laboratory DTI 4,79 *
Pdesign at -10°C kW 3,00
Input power heating (Nominal) kW 0,74
Input power heating (Min) kW 0,17
Input power heating (Max) kW 1,51
Annual energy consumption heating (4) kWh/a 894
Cooling capacity (Nominal) kW 2,50
Cooling capacity (Min) kW 0,85
Cooling capacity (Max) kW 3,40
SEER (3) 8,10 A++
Pdesign (cooling) kW 2,50
Input power cooling (Nominal) kW 0,51
Input power cooling (Min) kW 0,17
Input power cooling (Max) kW 0,88
Annual energy consumption cooling (4) kWh/a 108
Indoor unit CS-Z25UFEAW-1
Indoor air flow (Heat) m³/min 9,9
Indoor air flow (Cool) m³/min 9,6
Moisture removal volume L/h 1,5
Indoor sound pressure (Heat -Hi) (5) dB(A) 38
Indoor sound pressure (Heat -Lo) (5) dB(A) 25
Indoor sound pressure (Heat -Q-Lo) (5) dB(A) 19
Indoor sound pressure (Cool -Hi) (5) dB(A) 38
Indoor sound pressure (Cool -Lo) (5) dB(A) 25
Indoor sound pressure (Cool -Q-Lo) (5) dB(A) 20
Indoor dimension (Height) mm 600
Indoor dimension (Width) mm 750
Indoor dimension (Depth) mm 207
Indoor net weight kg 13
nanoe X Generator Mark 1
Outdoor unit CU-Z25UFEA-1
Outdoor power source V 230
Outdoor air flow (Heat) m³/min 32,2
Outdoor air flow (Cool) m³/min 32,2 
Outdoor sound pressure (Heat -Hi) (5) dB(A) 48
Outdoor sound pressure (Heat -Lo) (5) dB(A) 45
Outdoor sound pressure (Cool -Hi) (5) dB(A) 46
Outdoor sound pressure (Cool -Lo) (5) dB(A) 43
Outdoor dimension (Height) (6) mm 622
Outdoor dimension (Width) (6) mm 824
Outdoor dimension (Depth) (6) mm 299
Outdoor net weight kg 34
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 20
Elevation difference (in/out) (7) m 15
Pipe length for additional gas m 7,5
Additional gas amount g/m 10
Refrigerant (R32) / CO2 Eq. kg / T 0,97 / 0,65475
Operating range (Heat - Min) °C -25
Operating range (Heat - Max) °C +24
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +43
Lowest outdoor temperature tested by 3rd party laboratory (8) °C -35

(1) COP-beräkningen utförd i enlighet med EN 14511.
(2) Kapacitet av värmepumpen är testad under maximalt effekt och avfrostning.
(3) Energimärkning skala från A+++ till D. * SCOP testat av oberoende testlaboratorium DTI i enligthet med EN 14825:2016.
(4) Den årliga energiförbrukningen är beräknad i enlighet med EU-förordning 626/2011.
(5) Ljudtrycksnivån för enheterna visar det uppmätta värdet från en position 1 m framför huvudenheten och 1 m över golvet. Ljudtrycket är uppmätt i enlighet med JIS C 9612. Q-låg: Tyst läge. Låg: Den lägsta inställda fläkthastigheten.
(6) Lägg till 70 mm för röringång.
(7) Vid installation av utomhusenheten i högre läge än inomhusenheten.
(8) Testat av DTI, ett oberoende testlaboratorium, i enlighet med EN 14511:2013, denna temperatur garanteras inte av fabriken.