7 kW. 1-fazna enota Aquarea High Performance bi-bloc generacije J • R32

KIT-WC07J3E5 (WH-SDC0709J3E5 + WH-UD07JE5)

Aquarea, inovativen nov nizkoenergijski sistem, ki temelji na tehnologiji toplotnih črpalk zrak-voda


Aquarea učinkovito ogreva vaš dom tudi pri izjemno nizkih zunanjih temperaturah. Aquarea lahko tudi hladi prostor poleti in zagotavlja toplo vodo vse leto.
Aquarea High Performance je linija za nove vgradnje in domove z nizko porabo energije. Izredna učinkovitost in energijski prihranki z zmanjšanimi emisijami CO2 in zelo majhno porabo prostora.
Sistem bi-bloc: sistem ima ločene notranje in zunanje enote, priključite pa ga na ogrevalni sistem oziroma sistem za toplo vodo.
  • <span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, " segoe="" ui",="" roboto,="" "helvetica="" neue",="" arial,="" sans-serif,="" "apple="" color="" emoji",="" "segoe="" ui="" symbol",="" "noto="" emoji";="" font-size:="" 0.8125rem;"="">Zelo učinkovito hladilno sredstvo R32
  • Razred energetske učinkovitosti A+++ (izstopna odprtina za vodo v povprečnem podnebju pri 35 °C)
  • Največja izhodna temperatura hidravličnega modula: 60 °C
  • Posebna programska oprema za domove z nizko porabo energije in z najmanjšo izhodno temperaturo: 20 °C
  • Deluje tudi, ko se zunanja temperatura spusti do –20 °C
  • Upravljanje v oblaku in storitev z enoto CZ-TAW1
  • Daljinski upravljalnik, ki je preprost za uporabo
  • Sanitarna topla voda z zunanjim zbiralnikom
  • Enostavna vgradnja in vzdrževanje
  • Vgrajen magnetni vodni filter in merilnik pretoka ter samodejni ventil za čiščenje zraka

Kako deluje toplotna črpalka na zrak Aquarea Air?

Tehnični podatki

Poglej vse
1-fazna enota Aquarea High Performance bi-bloc generacije J • R32 Single Phase (Power to indoor)
7 kW
Kit KIT-WC07J3E5
Heating capacity (A +7°C, W 35°C) kW 7,00
COP (A +7°C, W 35°C) 4,76
Heating capacity (A +7°C, W 55°C) kW 7,00
COP (A +7°C, W 55°C) 2,82
Heating capacity (A +2°C, W 35°C) kW 6,85
COP (A +2°C, W 35°C) 3,41
Heating capacity (A +2°C, W 55°C) kW 6,20
COP (A +2°C, W 55°C) 2,21
Heating capacity (A -7°C, W 35°C) kW 5,60
COP (A -7°C, W 35°C) 2,87
Heating capacity (A -7°C, W 55°C) kW 5,25
COP (A -7°C, W 55°C) 1,94
Cooling capacity (A 35°C, W 7°C) kW 6,70
EER (A 35°C, W 7°C) 3,03
Cooling capacity (A 35°C, W 18°C) kW 6,70
EER (A 35°C, W 18°C) 4,72
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 193 / 130
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,90 / 3,32
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 227 / 160
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,75 / 4,07
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 164 / 116
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,18 / 2,98
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+
Indoor unit WH-SDC0709J3E5
Indoor sound pressure (Heat) dB(A) 30
Indoor sound pressure (Cool) dB(A) 30
Indoor dimension (Height) mm 892
Indoor dimension (Width) mm 500
Indoor dimension (Depth) mm 340
Indoor net weight kg 42
Water pipe connector Inch R 1¼
A class pump (Number of speeds) Variable Speed
A class pump (Input power Min) W 34
A class pump (Input power Max) W 114
Heating water flow (∆T=5 K. 35°C) L/min 20,10
Capacity of integrated electric heater kW 3,00
Indoor recommended fuse A 15 / 30
Recommended cable size, supply 1 mm² 3 x 2,5
Recommended cable size, supply 2 mm² 3 x 1,5
Outdoor unit WH-UD07JE5
Outdoor sound power part load (Heat) (3) dB(A) 59
Outdoor sound power full load (Heat) dB(A) 68
Outdoor sound power full load (Cool) dB(A) 67
Outdoor dimension (Height) mm 795
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 61
Refrigerant (R32) / CO2 Eq. kg / T 1,27 / 0,857
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 3 ~ 50
Elevation difference (in/out) m 30
Pipe length for additional gas m 10
Additional gas amount g/m 25
Operation range (Outdoor ambient) °C -20 ~ +35
Water outlet (Heat) °C 20 ~ 60
Water outlet (Cool) °C 5 ~ 20

(1) Zvočna moč v skladu z 8112013, 81312013 in EN12102-1:2017 pri +7 °C.
Izračun EER in COP je izdelan na podlagi EN14511.