Aquarea High Performance Mono-bloc H Generation 1 Phase • R410A
16kW
WH-MDC16H6E5
Aquarea, an innovative new low-energy system based on Air to Water heat pump technology
Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
The Mono‑Bloc system: This only has an outdoor unit. The installation doesn’t require a refrigerated connection and is only connected to the heating and/or hot water.
- A+++ energy Class (average climate at 35°C water outlet)
- High heating and cooling capacities, even at low outdoor temperatures
- Special software for low consumption homes with minimum output temperature: 20°C
- Works at temperatures as low as -20°C
- Cloud control and service with CZ-TAW1
- Easy-to-use remote controller
- Domestic hot water with external tank
- Easy installation and maintenance
- Built-in flow meter, and automatic air purge valve
Toplotna pumpa pretvara toplotnu energiju iz okoline u unutrašnju toplotu
Aquarea Service Cloud Kontrola za danas i za budućnost
Aquarea Service Cloud Kontrola za danas i za budućnost

Toplotna pumpa vazduh–voda
Sistemi grejanja, hlađenja i tople vode za domaćinstvo
za ekološku budućnost.
Toplotna pumpa vazduh–voda
Sistemi grejanja, hlađenja i tople vode za domaćinstvo
za ekološku budućnost.

Specifikacije
Aquarea High Performance Mono-bloc H Generation 1 Phase • R410A | |||
---|---|---|---|
16 kW | |||
Spoljna jedinica | WH-MDC16H6E5 | ||
Kapacitet grejanja(A +7°C, W35°C) | kW | 16,00 | |
COP (A +7°C, W 35°C) | 4,28 | ||
Kapacitet grejanja (A +7°C, W55°C) | kW | 14,50 | |
COP (A +7°C, W 55°C) | 2,72 | ||
Kapacitet grejanja (A +2°C, W 35°C) | kW | 13,00 | |
COP (A +2°C, W 35°C) | 3,28 | ||
Kapacitet grejanja (A +2°C, W 55°C) | kW | 9,80 | |
COP (A +2°C, W 55°C) | 2,21 | ||
Kapacitet grejanja (A -7°C, W 35°C) | kW | 11,40 | |
COP (A -7°C, W 35°C) | 2,57 | ||
Kapacitet grejanja (A -7°C, W 55°C) | kW | 9,00 | |
COP (A -7°C, W 55°C) | 1,84 | ||
Kapacitet hlađenja (35°C, W7°C) | kW | 12,20 | |
EER (35°C, W7°C) | 2,56 | ||
Kapacitet hlađenja (35°C, W18°C) | kW | 12,20 | |
EER (35°C, W18°C) | 4,12 | ||
Grejanje prosečne klime. Sezonska energetska efikasnost (W 35°C / W 55°C) | ηs % | 190 / 130 | |
Grejanje prosečne klime. Sezonska energetska efikasnost (W 35°C / W 55°C) | SCOP | 4,83 / 3,33 | |
Grejanje prosečne klime. Energetska klasa (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
Grejanje tople klime. Sezonska energetska efikasnost (W 35°C / W 55°C) | ηs % | 245 / 169 | |
Grejanje tople klime. Sezonska energetska efikasnost (W 35°C / W 55°C) | SCOP | 6,20 / 4,30 | |
Grejanje tople klime. Energetska klasa (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
Grejanje hladne klime. Sezonska energetska efikasnost (W 35°C / W 55°C) | ηs % | 168 / 121 | |
Grejanje hladne klime. Sezonska energetska efikasnost (W 35°C / W 55°C) | SCOP | 4,28 / 3,10 | |
Grejanje hladne klime. Energetska klasa (W 35°C / W 55°C) (1) | A+++ to D | A++ / A+ | |
Spoljno opterećenje dela zvučne snage (grejanje) (1) | dB(A) | 65 | |
Spoljašnja- zvučna snaga pri puno, opterećenju (grejanje) | dB(A) | 72 | |
Spoljašnja- zvučna snaga pri puno, opterećenju (hlađenje) | dB(A) | 72 | |
Spoljna jedinica- dimenzija (visina) | mm | 1410 | |
Spoljna j. dimenzija (širina) | mm | 1283 | |
Spoljna j. dimenzija (dubina) | mm | 320 | |
Spoljna jedinica-neto težina | kg | 140 | |
Rashladno sredstvo (R32) / CO2 Eq. (2) | kg / T | 2,10 / 4,385 | |
Rashladno sredstvo (R410A) / CO2 Eq. (2) | kg / T | 2,10 / 4,385 | |
Konektor cevi za vodu | Inch | R 1¼ | |
Pumpa (broj brzina) | Variable Speed | ||
Pumpa (ulazni napon Min) | W | 38 | |
Pumpa (maks. ulazne napona) | W | 120 | |
Isparavanje vode (ΔT=5 K. 35°C) | L/min | 45,90 | |
Kapacitet integrisanog električnog grejača | kW | 6,00 | |
Ulazni napon (grejanje) | kW | 3,74 | |
Ulazni napon (hlađenje) | kW | 4,76 | |
Pokretanje struje (grejanje) | A | 16,9 | |
Pokretanje struje (hlađenje) | A | 21,5 | |
Struja 1 | A | 26 | |
Struja 2 | A | 26 | |
Unutrašnja jedinica- preporučeni osigurač | A | 30 / 30 | |
Preporučena veličina kabla, snabdevanje 1 | mm² | 3 x 4,0 or 6,0 | |
Preporučena veličina kabla, snabdevanje 2 | mm² | 3 x 4,0 | |
Opseg rada – spoljna temperatura (grejanje) | °C | -20 ~ +35 | |
Izlaz za vodu (toplota) | °C | 25 ~ 55 | |
Izlaz za vodu (hladan) | °C | 5 ~ 20 |
(1) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
(2) WH-MDC models are hermetically sealed.