Unité murale BZ ultra-compacte Inverter

Les unités murales de la gamme BZ avec filtre PM2,5 sont compactes, silencieuses et de haute qualité.

Découvrez la dernière génération de systèmes d’air conditionné

La climatisation de demain

Caractéristiques

Voir tout
BZ ultra-compact · R32 Monophasé
6.00 kW
Kit KIT-BZ60-ZKE
Cooling capacity (Nominal) kW 6,00
Cooling capacity (Min) kW 0,98
Cooling capacity (Max) kW 6,50
EER (Nominal) (1) W/W 3,03
EER (Min) (1) W/W 3,92
EER (Max) (1) W/W 2,83
SEER (2) 6,40 A++
Pdesign (cooling) kW 6
Input power cooling (Nominal) kW 1,98
Input power cooling (Min) kW 0,25
Input power cooling (Max) kW 2,30
Annual energy consumption cooling (3) kWh/a 328
Heating capacity (Nominal) kW 6,80
Heating capacity (Min) kW 0,98
Heating capacity (Max) kW 8,00
Heating capacity at -7°C kW 5,1
COP (Nominal) (1) W/W 3,16
COP (Min) (1) W/W 4,26
COP (Max) (1) W/W 3,02
SCOP (2) 4,10 A+
Pdesign at -10°C kW 4,4
Input power heating (Nominal) kW 2,15
Input power heating (Min) kW 0,23
Input power heating (Max) kW 2,65
Annual energy consumption heating (3) kWh/a 1.502
Indoor unit CS-BZ60ZKE
Indoor power source V 230
Indoor recommended fuse A 20
Indoor connection indoor / outdoor mm² 4 x 2,5
Indoor air flow (Cool) m³/min 12,7
Indoor air flow (Heat) m³/min 13,6
Moisture removal volume L/h 3,3
Indoor sound pressure (Cool -Hi) (4) dB(A) 45
Indoor sound pressure (Cool -Lo) (4) dB(A) 37
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 34
Indoor sound pressure (Heat -Hi) (4) dB(A) 45
Indoor sound pressure (Heat -Lo) (4) dB(A) 37
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 34
Indoor dimension (Height) mm 290
Indoor dimension (Width) mm 779
Indoor dimension (Depth) mm 209
Indoor net weight kg 9
Outdoor unit CU-BZ60ZKE
Outdoor air flow (Cool) m³/min 42,6
Outdoor air flow (Heat) m³/min 39,2
Outdoor sound pressure (Cool -Hi) (4) dB(A) 50
Outdoor sound pressure (Heat -Hi) (4) dB(A) 50
Outdoor dimension (Height) (5) mm 695
Outdoor dimension (Width) (5) mm 875
Outdoor dimension (Depth) (5) mm 320
Outdoor net weight kg 40
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 30
Elevation difference (in/out) (6) m 15
Pipe length for additional gas m 7,5
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,11 / 0,75
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) Le calcul des coefficients EER et COP est conforme à la norme européenne EN14511.
2) Label énergétique allant de A+++ à D.
3) La consommation annuelle d’énergie est calculée conformément à la directive UE/626/2011.
4) Le niveau de pression sonore de l’unité intérieure indique la valeur pour une position à 1 m en face du corps principal et à 0,8 m en dessous de l’unité. Pour une unité extérieure, 1 m en face et 1 m sur le côté arrière du corps principal. La pression sonore est mesurée conformément à la norme JIS C 9612. Q-Faible : mode silencieux. Faible : Vitesse de consigne minimale du ventilateur.
5) Ajouter 70 mm pour l’orifice des tuyauteries.