Kit de connection CTA Kit pour PACi, ECOi and l'ECO G

AHU Kit combine air conditioning and fresh air in just one solution.

New AHU Kits connect ECOi systems to air handling unit systems, using the same refrigerant circuit as the VRF system.
Large connectivity possibilities mean the Panasonic AHU Kit can be easily integrated.
Heat exchanger, Fan & Fan motor to be mounted in AHU Kit shall be provided in the field.
AHU connection Kit (field supplied) AHU Kit system. (Contents of kit: Control for PCB, expansion valve, sensors).
AHU Kit combine air conditioning and fresh air in just one solution.
The Panasonic AHU Kits offer a wealth of connectivity possibilities so can be easily integrated into many systems.
Application: Hotels, offices, server rooms or all large buildings where air quality control such as humidity control and fresh air and is needed.
Besides the advantages in terms of indoor air quality, air conditioning offers also an energy saving potential. For example, while uncontrolled ventilation through open windows leads to large amounts of heat being lost to the outside during the heating season or gained from the outside during the cooling season, air conditioning systems provide possibilities to utilize the extra “free” energy in heat recovery modules so that overall operating costs will be reduced.
The larger the area of the comfort range, the better the energy saving opportunities.
Panasonic AHU Kit, 10-25kW connecté à l'unité extérieure PACi
Le nouveau kit d'unité de traitement de l'air a été développé pour mieux répondre à la demande des clients: IP 65 Box pour être installé à l'extérieur, contrôle de la demande 0-10V * et contrôle facile par BMS
* Disponible uniquement avec Elite PACi, jusqu'à 6kW à 14kW.


Panasonic AHU Kit, 16-56kW connecté à ECOi ou ECO G
PCB, transformateur, vanne de régulation solénoïde, thermistance x 4 pcs, bornier et boîte à composants électriques.
Principaux composants des systèmes de ventilation mécanique
Les principaux composants d'un système de ventilation mécanique sont les suivants: Centrale de traitement d'air (CTA), gaines d'air et éléments de diffusion de l'air.
Empty
Contrôle de la demande sur l'unité extérieure gérée par un signal 0-10V externe.
1. Kit de contrôle CTA
2. BMS externe
3. 0-10V Contrôle de la capacité
4. Unité extérieure PACi ou ECOi / ECO G
5. Unité de traitement de l'air (AHU)

1. Air d'échappement
2. Air extérieur
3. Retour de l'air
4. Fourni de l'air

AHU Kit connects PACi outdoor units to Air Handling Units system
The Panasonic AHU Kits offer a wealth of connectivity possibilities so can be easily integrated into many systems.
Application: Hotels, offices, server rooms or all large buildings where air quality control such as humidity control and fresh air and is needed.

1. Remote control CZ-RTC4
2. New plastic IP 65 Box
3. PAW‑T10 PCB for dry contact
4. 0-10V demand control PCB
5. Intelligent thermostat for:
  • Cold draft prevention
  • Outdoor temperature shift compensation
6. Terminal base for sensors and power supply
AHU Connection Kit
PCB, Power trans, Terminal block
Thermistor x2 (Refrigerant: E1, E2)
Thermistor (Air: TA; 1 sensor)
Standard wired remote controller.

AHU Kit 10-25kW for PACi

AHU Kit connects PACi outdoor units to Air Handling Units system

Control option 1: PAW-280PAH2L
  • The system’s control is simple: control of actual suction temperature vs. set point
  • Control works in the same way as that of any indoor unit
  • Fan signal issued by the PCB (OFF while defrosting, for instance)
Control option 2: PAW-280PAH2
  • System control by probe located at air intake. Sensor works as a 0–10V control thermostat which manages the set point temperature. Control to prevent cold draughts.
  • All signals as per standard
Control option 3: PAW-280PAH2
  • System control by external environment probe. Sensor works as a 0–10V control thermostat which manages the set point temperature. Enhances efficiency by adjusting capacity to the ambient temperature and enhances comfort as well.
  • All signals as per standard
Control option 4: PAW-280PAH2
  • System control by a 0–10V control working from an external BMS that manages the set point for the temperature or the capacity. Enhances efficiency by adjusting capacity to the ambient temperature and enhances comfort as well.
  • All signals as per standard

3 types de CTA: Deluxe, Medium and Light

PAW-280PAH2: IP 65, 0-10V contrôle de la demande * et compensation de la température extérieure. Prévention des brouillons froids.
PAW-280PAH2M: contrôle de la demande IP 65 et 0-10V *.
PAW-280PAH2L: IP 65.


* Avec CZ-CAPBC2.

Kit CTA 16, 28 et 56kW pour l'ECOi et l'ECO G 

L'unité extérieure de la série ECOi 2 tubes 6N doit être utilisée pour le kit de connexion CTA.

Exemple de système pour une grande capacité (plus de 56kW)
3 x [PCB, Transformateur, Valve de contrôle solénoïde, Thermistance x 4 pcs, Base de borne et Boîte à composants électriques]. Exemple de système 140kW.
1. Tube à gaz / 2. Tube liquide / 3. Unité extérieure / Communication de l'unité intérieure / 4. Température d'entrée / 5. Température de sortie / 6. Température du liquide / 7. Température du gaz / 8. Signal de fonctionnement du ventilateur / 9. Contrôle du moteur du ventilateur PCB

3 types de kit CTA: Deluxe, Medium et Light.

PAW-160MAH2 / PAW-280MAH2 / PAW-560MAH2: IP 65, 0-10V contrôle de la demande * et compensation de la température extérieure. Prévention des brouillons froids.
PAW-160MAH2M / PAW-280MAH2M / PAW-560MAH2M: contrôle de la demande IP 65 et 0-10V *.
PAW-160MAH2L / PAW-280MAH2L / PAW-560MAH2L: IP 65.

Pièces optionnelles: les fonctions suivantes sont disponibles en utilisant différents accessoires de commande:

Commande à distance de la minuterie CZ-RTC4.

• Fonctionnement-ON / OFF
• Sélection du mode
• Réglage de la température
• Le signal de fonctionnement du ventilateur peut être retiré de la carte PCB.


CZ-CAPBC2 Mini unité seri-para I / O (version avancée uniquement).


• Intégration facile dans les systèmes de contrôle AHU externes et BMS
• Contrôle de la demande: 40 à 115% (5% étapes) du courant nominal par signal d'entrée 0-10V *
• Réglage de la température cible par 0-10V ou 0-140Ω signal d'entrée *
• Sortie de la température de l'air de l'alimentation par signal 4-20mA
• Sélection du mode ou / et commande ON / OFF
• Contrôle de l'opération du ventilateur
• Sortie d'état de fonctionnement / Sortie d'alarme
• Contrôle du MARCHE / ARRET du thermostat



*Le contrôle de la demande par BMS externe ne peut pas être combiné avec le contrôle de la demande ou le réglage de la température cible, effectué par le thermostat. Cependant, si le contrôle simultané de la demande et le réglage de la température cible sont nécessaires, cela ne peut être réalisé qu'en utilisant une deuxième interface (optionnelle) CZ-CAPBC2.
PAW-OCT, prise DC12V. Borne OPTION.

• Signal de sortie = état de refroidissement / chauffage / ventilateur
• Décongelation
• Thermostat-ON


Borne CZ-T10 / PAW-T10 pour se connecter au connecteur T10.


• Une PCB à contact sec a été développée pour contrôler facilement l'unité
• Fonctionnement du signal d'entrée activé / désactivé
• Interdiction de la télécommande
• Signal de sortie Fonctionnement état ON maximum 230V 5A (NO / NC)
• Etat de l'alarme du signal de sortie max. 230V 5A (NO / NC)
• Sortie d'alarme (par DC12V)
• Autres contacts disponibles:


- Commande humidificateur externe (ON / OFF) 230VAC 3A
- Commande de ventilateur externe (ON / OFF) 12V DC
- Potentiel de signal d'état du filtre externe libre
- Potentiel de signalisation de flotteur externe libre
- Capteur de détection de fuite externe ou TH. OFF sans potentiel de contact (utilisation possible pour la régulation externe de la température de soufflage)