Seria PACi NX Elite, tavan, Invertor+ - R32

10.0kW

KIT-100PT3ZH48 (S-1014PT3E + U-100PZH4E8)

Unitățile cu montaj pe tavan asigură o distribuție amplă a aerului, potrivită pentru încăperile mari.

Înălțimea și adâncimea tuturor capacităților sunt identice, pentru un aspect unitar în instalațiile mixte.

Generația următoare de aparate comerciale de aer condiționat este aici

Specificații

Vizualizare toate
Seria PACi NX Elite, tavan, Invertor+ - R32
10.0 kW
Kit KIT-100PT3ZH48
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 9,5
Cooling capacity (Min) kW 3,1
Cooling capacity (Max) kW 12,5
EER (Nominal) (1) W/W 4,06
EER (Min) (1) W/W 3,29
EER (Max) (1) W/W 5,34
SEER/ηsc (2) % 7,2 A++
Pdesign (cooling) kW 9,5
Input power cooling (Nominal) kW 2,34
Input power cooling (Min) kW 0,58
Input power cooling (Max) kW 3,80
Annual energy consumption cooling (3) kWh/a 462
Heating capacity (Nominal) kW 11,2
Heating capacity (Min) kW 3,1
Heating capacity (Max) kW 14,0
COP (Nominal) (1) W/W 4,00
COP (Min) (1) W/W 3,54
COP (Max) (1) W/W 5,54
SCOP/ηsc (2) % 4,5 A+
Pdesign at -10°C kW 7,8
Input power heating (Nominal) kW 2,80
Input power heating (Min) kW 0,56
Input power heating (Max) kW 3,95
Annual energy consumption heating (3) kWh/a 2.427
Indoor unit S-1014PT3E
Indoor air flow (Hi) m³/min 30,0
Indoor air flow (Med) m³/min 25,0
Indoor air flow (Lo) m³/min 23,0
Moisture removal volume L/h 3,6
Indoor sound pressure (Med) (4) dB(A) 37
Indoor sound pressure (Lo) (4) dB(A) 34
Indoor sound power (Hi) dB(A) 60
Indoor sound power (Med) dB(A) 55
Indoor sound power (Lo) dB(A) 52
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
nanoe X Generator Mark 2
Outdoor unit U-100PZH4E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,60
Current in cooling (1p 230V / 3p 400) A 3,40
Current in cooling (1p 240V / 3p 415) A 3,25
Current in heating (1p 220V / 3p 380) A 3,75
Current in heating (1p 230V / 3p 400) A 3,55
Current in heating (1p 240V / 3p 415) A 3,40
Outdoor air flow (Cool) m³/min 76,0
Outdoor air flow (Heat) m³/min 70,0
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 69
Outdoor sound power (Heat -Hi) dB(A) 69
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 82
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R32) / CO2 Eq. kg / T 2,70 / 1,82
Operating range (Cool - Min) °C -20 (8)
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) Calculul EER și COP se realizează în conformitate cu EN14511.
2) Pentru modelele sub 12 kW, SEER și SCOP se calculează pe baza valorilor din UE/626/2011. Pentru modelele peste 12 kW, valorile ηs,c / ηs,h sunt calculate pe baza EN 14825.
3) Setare din fabrică.
4) Presiunea sonoră a unităților indică valoarea măsurată într-un punct situat la o distanță de 1 m în fața corpului principal și la 1 m sub unitate. Presiunea sonoră se măsoară conform specificației Eurovent 6/C/006-97.
5) Conectați conducta racordului de lichid (Ø6,35-Ø9,52) la conducta de lichid a unității de interior.
6) Conectați conducta racordului de gaz (Ø12,70-Ø15,88) la conducta de gaz a unității de interior.
7) Unitate de exterior amplasată mai jos/unitate de exterior amplasată mai sus.
8) Lungime conducte de până la 30 m.

* Siguranță fuzibilă recomandată pentru interior 3A.
** Valorile de mai sus sunt valabile pentru nanoe™ X oprită.