T-CAP All in One 260L DHW tank M Series 1 phase - 3 phase · R290

9kW

WH-WXG09ME8 + WH-ADC0316M9E83 / WH-WXG09ME8 + WH-ADC0316M9E8AN3

T-CAP All in One 260L DHW tank M Series 1 phase - 3 phase · R290

Aquarea T‑CAP M Series delivers a revolution in the design, performance, connectivity, and sustainability

The solution is suitable for both new buildings and retrofits, as it offers a sustainable alternative to traditional fossil fuel heating systems and it can be easily integrated with existing water system such as fan coils, floor heating or domestic hot water tanks.

Now available in a larger All in One version, perfect for homes with high DHW demand. Despite the increased capacity, it maintains a compact footprint of just 599 x 602 mm—similar to a standard appliance.

• Up to 75°C water outlet down to -15°C outdoor
• Quiet operation: Only 29dB(A) sound pressure at 5 m*
• Reliable outdoor units with Panasonic compressor, operating down to -28°C outdoor
• T‑CAP technology: Keeping heating capacity down to -15°C at 55ºC water outlet
• Panasonic Comfort Cloud App and Aquarea Service Cloud included
• Hydraulic connection between indoor and outdoor
• Maintenance free Inox stainless 260L tank
• All in One 599 x 602mm footprint reduces required installation space indoors
• U-Vacua™ insulation panel for higher tank efficiency
• Also available with built-in impressed current anode (AN version) for installation in sites with harsh water quality

Confort suplimentar și liniște sufletească cu Aquarea

Specificații

Vizualizare toate
T-CAP All in One 260L DHW tank M Series 1 phase - 3 phase · R290
9 kW
Water volume L 260
Outdoor dimension (Depth) mm 430
Outdoor dimension (Width) mm 1.200
DHW tank ERP cold climate η ηwh % 95
DHW tank ERP warm climate η ηwh % 136
DHW tank ERP average climate η ηwh % 125
Tapping profile according EN16147 XL
Material inside tank Stainless steel
Maximum water temperature °C 65
Elevation difference (in/out) m 10
Heating water flow (∆T=5 K. 35°C) L/min 25,8
A class pump (Input power Max) W 175
A class pump (Input power Min) W 30
A class pump (Number of speeds) Variable speed
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,45 / 3,20
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 175 / 125
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Indoor unit 6kW electric heater
Outdoor sound power (Heat) (2) dB(A) 52
Indoor unit 9kW electric heater WH-ADC0316M9E83
Pipe length range maximum m 30
Pipe length range standard m 5
Water pipe connector (outdoor units) Inch
Water pipe connector (indoor units) Inch
Water pipe connector (shower) Inch 3/4
Water pipe connector (room) Inch
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,33 / 4,40
Indoor unit 3kW electric heater
DHW tank ERP cold climate COPdHW COPdHW 2,35
DHW tank ERP warm climate COPdHW COPdHW 3,35
DHW tank ERP average climate COPdHW COPdHW 3,10
Operation range - outdoor temperature (Cool) °C +10 ~ +43
Operation range - outdoor temperature (Heat) °C -28 ~ +35
Water outlet (Cool) °C 5 ~20
Water outlet (Heat) °C 25 ~ 75 (4)
COP (A +7°C, W 35°C) 5,23
Indoor net weight kg 105
Indoor dimension (Height) mm 2.036
EER (A 35°C, W 7°C) 3,61
Cooling capacity (A 35°C, W 7°C) kW 9,00
COP (A -7°C, W 35°C) 3,45
Heating capacity (A -7°C, W 35°C) kW 9,00
COP (A +2°C, W 35°C) 3,81
Heating capacity (A +2°C, W 35°C) kW 9,00
Outdoor dimension (Height) mm 1.520
Heating capacity (A +7°C, W 35°C) kW 9,00
COP (A +2°C, W 55°C) 2,54
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 250 / 173
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,00 / 3,50
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 197 / 137
EER (A 35°C, W 18°C) 5,26
Cooling capacity (A 35°C, W 18°C) kW 9,00
COP (A -7°C, W 55°C) 2,35
Heating capacity (A -7°C, W 55°C) kW 9,00
Heating capacity (A +2°C, W 55°C) kW 9,00
COP (A +7°C, W 55°C) 3,24
Heating capacity (A +7°C, W 55°C) kW 9,00
Outdoor unit WH-WXG09ME8
Indoor dimension (Depth) mm 602
Indoor dimension (Width) mm 599
Outdoor net weight kg 161
(1) Scale from A+++ to D.
(2) Sound power level in accordance to EN 12102 under conditions of the EN14825 (part load).
(3) WH-WXG models are hermetically sealed.
(4) Above -15 °C outdoor temperature. Between outdoor ambient -15 °C and -25 °C, the water outlet temperature gradually decreases from 75 °C to 55 °C. Below -25 °C outdoor temperature maximum water outlet temperature is 55 °C.
(5) Check local regulations.

* EER and COP calculation is based in accordance to EN 14511.

Ce se întâmplă