Power Heat Multi Z - R32

Power Heat Multi Z - R32

Sistemul multi split proiectat pentru climatele reci. Încălzire puternică a două sau trei camere cu o singură unitate exterioară, chiar și la temperaturi exterioare scăzute de -25°C.

Gestionați soluțiile Panasonic oricând, oriunde

Specificații

Vizualizare toate
Power Heat Multi Z - R32 SINGLE PHASE
5.30 kW 7.50 kW
Cooling capacity (Min) kW 2,10 2,10
Cooling capacity (Max) kW 7,50 8,80
Input power cooling (Min) kW 0,36 0,38
Input power cooling (Max) kW 2,06 2,45
Heating capacity (Min) kW 1,70 1,70
Heating capacity (Max) kW 8,70 10,60
Input power heating (Min) kW 0,32 0,32
Input power heating (Max) kW 2,44 2,92
Elevation difference (in/out) m 15 15
Power supply V 230 230
Current heating A 6,80 8,80
Current cooling A 5,70 8,50
Operating range (Heat - Max) °C +24 +24
Heating capacity at -15°C (Max) kW 5,90 6,30
Heating capacity at -25°C (Max) kW 3,90 4,30
Outdoor sound pressure (Cool -Hi) (3) dB(A) 49 49
Outdoor sound pressure (Heat -Hi) (3) dB(A) 49 53
Outdoor dimension (Height) (4) mm 795 795
Outdoor dimension (Width) (4) mm 875 875
Outdoor dimension (Depth) (4) mm 320 320
Indoor nominal capacity (Min ~ Max) kW 0,85 ~ 3,6 0,85 ~ 7,5
Pipe length range to one unit m 3 ~ 25 3 ~ 25
Pipe length range total m 50 60
Input power heating (Nominal) kW 1,53 2,02
Outdoor net weight kg 58 62
SEER (2) 8,00 A++ 8,00 A++
Pdesign (cooling) kW 5,30 7,50
Input power cooling (Nominal) kW 1,26 1,94
SCOP (2) 4,40 A+ 4,60 A++
Pdesign at -10°C kW 5,10 5,60
Operating range (Cool - Min) °C -10 -10
Cooling capacity (Nominal) kW 5,30 7,50
Heating capacity (Nominal) kW 6,40 8,60
COP (Nominal) (1) W/W 4,18 4,26
EER (Nominal) (1) W/W 4,21 3,87
Refrigerant (R32) / CO2 Eq. kg / T 1,92 / 1,296 2,42 / 1,634
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52)
Pipe length for additional gas m 30 30
Additional gas amount g/m 20 20
Outdoor unit CU-2Z50ABEC CU-3Z75ABEC
Operating range (Cool - Max) °C +46 +46
Operating range (Heat - Min) °C -25 -25

1) Calculul EER și COP se bazează în conformitate cu EN 14511.
2) Scala etichetei energetice de la A+++ la D.
3) Presiunea acustică a unităților arată valoarea măsurată dintr-o poziție de 1m în fața și 1m în spatele corpului principal. Presiunea acustică este măsurată în conformitate cu JIS C 9612.
4) Adăugați 70 sau 95 mm pentru orificiul conductei.

Ce se întâmplă