6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 10.0 kW 12.5 kW 14.0 kW
Komplet KIT-60PF3Z25 KIT-71PF3Z25 KIT-100PF3Z25 KIT-125PF3Z25 KIT-140PF3Z25 KIT-100PF3Z28 KIT-125PF3Z28 KIT-140PF3Z28
Daljinski upravljač CZ-RTC6 CZ-RTC6 CZ-RTC6 CZ-RTC6 CZ-RTC6 CZ-RTC6 CZ-RTC6 CZ-RTC6
Kapacitet hlađenja (Nominalni) kW 5,7 6,8 9,5 12,1 13,4 9,5 9,5 13,4
Kapacitet hlađenja (min) kW 2,0 2,2 3,1 3,2 3,3 3,0 3,0 3,3
Kapacitet hlađenja (maks.) kW 6,3 7,8 11,4 13,5 15,0 11,4 11,4 15,0
EER (Nominalni) (1) W/W 3,63 3,15 3,57 3,40 3,16 3,57 3,40 3,16
EER (min.) (1) W/W 4,76 4,76 6,00 5,93 5,08 6,00 5,93 5,08
EER (maks.) (1) W/W 2,50 2,70 2,36 2,76 2,56 2,36 2,76 2,56
SEER/sc (2) % 7,1 A++ 6,7 A++ 6,6 A++ 257,5 252,6 6,5 A++ 256,5 251,7
Pdesign (hlađenje) kW 5,7 6,8 9,5 12,1 13,4 9,5 12,1 13,4
Ulazna električna snaga hlađenja (nominalno) kW 1,57 2,16 2,66 3,56 4,24 2,66 3,56 4,24
Ulazno hlađenje (Min) kW 0,42 0,42 0,50 0,54 0,65 0,50 0,54 0,65
Ulazno hlađenje (maks.) kW 2,52 2,85 4,84 4,90 5,86 4,84 4,90 5,86
Godišnja potrošnja energije (3) kWh/a 281 354 502 508
Kapacitet grijanja (Nominalni) kW 5,7 6,8 9,5 12,1 13,4 9,5 12,1 13,4
Kapacitet grijanja (Min) kW 1,8 1,8 3,0 3,3 3,4 3,0 3,3 3,4
Kapacitet grijanja (maks.) kW 7,0 8,1 13,5 15,0 16,0 13,5 15,0 16,0
COP (Nominalni) (1) W/W 4,22 3,93 4,09 3,56 3,76 4,09 3,56 3,76
COP (min) (1) W/W 4,86 4,86 6,00 6,11 5,23 6,00 6,11 5,23
COP (maks.) (1) W/W 2,83 3,82 3,00 3,16 3,03 3,00 3,16 3,03
SCOP/sc (2) % 4,7 A++ 4,2 A+ 3,9 A 144,2 140,8 3,9 A 144,1 140,8
Pdizajn na -10°C kW 4,4 4,7 7,8 9,3 9,5 7,8 9,3 9,5
Ulazna električna snaga grijanje (nominalno) kW 1,35 1,73 2,32 3,40 3,56 2,32 3,40 3,56
Grijanje ulazne snage (Min) kW 0,37 0,37 0,50 0,54 0,65 0,50 0,54 0,65
Grijanje ulazne snage (maks.) kW 2,47 2,12 4,50 4,74 5,28 4,50 4,74 5,28
Godišnja potrošnja energije (3) kWh/a 1289 1565 2795 2795
Unutarnje jedinice S-6071PF3E S-6071PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E
Vanjski statički tlak (Nominalni) (4) Pa 30 30 40 50 50 40 50 50
Vanjski statički tlak (Min) (4) Pa 10 10 10 10 10 10 10 10
Vanjski statički tlak (maks.) (4) Pa 150 150 150 150 150 150 150 150
Volumen uklanjanja vlage L/h 1,7 2,7 3,2 4,1 4,9 3,2 4,1 4,9
Unutarnji protok zraka (Hi) m³/min 21,0 21,0 32,0 34,0 36,0 32,0 34,0 36,0
Unutarnji protok zraka (Med) m³/min 19,0 19,0 26,0 29,0 32,0 26,0 29,0 32,0
Unutarnji protok zraka (Lo) m³/min 15,0 15,0 21,0 23,0 25,0 21,0 23,0 25,0
Unutarnji zvučni tlak (Hi) (5) dB(A) 30 30 33 35 39 33 35 39
Unutarnji zvučni tlak (Med) (5) dB(A) 26 26 29 31 35 29 31 35
Unutarnji zvučni tlak (Lo) (5) dB(A) 23 23 25 27 29 25 27 29
Snaga zvuka u zatvorenom prostoru (Hi) dB(A) 53 53 56 58 62 56 58 62
Unutarnja snaga zvuka (Med) dB(A) 49 49 52 54 58 52 54 58
Unutarnja snaga zvuka (Lo) dB(A) 46 46 48 50 52 48 50 52
Unutarnja dimenzija (visina) mm 250 250 250 250 250 250 250 250
Unutarnja dimenzija (Širina) mm 1000 1000 1400 1400 1400 1400 1400 1400
Unutarnja dimenzija (Dubina) mm 730 730 730 730 730 730 730 730
Unutarnja neto težina kg 30 30 39 39 39 39 39 39
nanoe X generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Vanjska jedinica U-60PZ2E5 U-71PZ2E5 U-100PZ2E5 U-125PZ2E5 U-140PZ2E5 U-100PZ2E8 U-125PZ2E8 U-140PZ2E8
Vanjski izvor napajanja V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Struja u hlađenju (1p 220V / 3p 380) A 7,55 10,40 12,10 16,40 19,20 4,15 5,50 6,40
Struja u hlađenju (1p 230V / 3p 400) A 7,20 9,95 11,60 15,70 18,40 3,95 5,25 6,10
Struja u hlađenju (1p 240V / 3p 415) A 6,90 9,55 11,10 15,10 17,60 3,80 5,05 5,90
Struja u grijanju (1p 220V / 3p 380) A 6,40 8,35 10,50 15,70 15,90 3,60 5,25 5,35
Struja u grijanju (1p 230V / 3p 400) A 6,15 8,00 10,00 15,00 15,20 3,40 5,00 5,05
Struja u grijanju (1p 240V / 3p 415) A 5,90 7,65 9,60 14,40 14,60 3,30 4,80 4,90
Vanjski protok zraka (Cool) m³/min 40 50 76 86 89 76 86 89
Vanjski protok zraka (grijanje) m³/min 45 45 70 78 83 70 78 83
Vanjski zvučni tlak (Cool -Hi) dB(A) 46 49 52 55 56 52 55 56
Vanjski zvučni tlak (grijalica -Hi) dB(A) 48 49 52 55 56 52 55 56
Vanjska snaga zvuka (Cool -Hi) dB(A) 65 69 70 73 74 70 73 74
Vanjska snaga zvuka (grijalica -Hi) dB(A) 68 69 70 73 74 70 73 74
Vanjska dimenzija (visina) mm 695 695 996 996 996 996 996 996
Vanjska dimenzija (Širina) mm 875 875 980 980 980 980 980 980
Vanjska dimenzija (Dubina) mm 320 320 370 370 370 370 370 370
Vanjska neto težina kg 44 44 90 94 94 90 94 94
Promjer cijevi (tečno) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Promjer cijevi (plin) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Raspon dužine cijevi m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50
Razlika u povećanju (ulaz/izlaz) (6) m 30 30 30 30 30 30 30 30
Dužina cijevi za dodatni plin m 30 30 30 30 30 30 30 30
Dodatna količina plina g/m 35 35 45 45 45 45 45 45
Rashladno sredstvo (R32) / CO2 Eq. kg / T 1,45 / 0,979 1,45 / 0,979 2,60 / 1,755 2,98 / 2,0115 2,98 / 2,0115 2,60 / 1,755 2,98 / 2,0115 2,98 / 2,0115
Radni raspon (Cool - Min) °C -10 -10 -10 -10 -10 -10 -10 -10
Radni raspon (Cool – maks.) °C +43 +43 +43 +43 +43 +43 +43 +43
Radni raspon (grijalica - min) °C -15 -15 -15 -15 -15 -15 -15 -15
Radni raspon (grijalica – maks.) °C +24 +24 +24 +24 +24 +24 +24 +24
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3A.
** Above values are in the case of standard installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.

Complementary products