PACI NX Standard - Cassettes 4 voies 90x90 Inverter+ - R32

Cassette 4 voies PU3

Un puissant ventilateur turbo et le capteur intelligent Econavi garantissent une haute efficacité énergétique, et nanoe™ X intégré de série procure un niveau exceptionnel de qualité de l’air intérieur.

La dernière génération de climatiseurs pour le tertiaire est arrivée

Caractéristiques

Voir tout
PACI NX Standard - Cassettes 4 voies 90x90 Inverter+ - R32
10.0 kW
Kit KIT-100PU3Z8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 10,0
Cooling capacity (Min) kW 3,0
Cooling capacity (Max) kW 11,5
EER (Nominal) (1) W/W 3,82
EER (Min) (1) W/W 5,36
EER (Max) (1) W/W 2,88
SEER/ηsc (2) % 6,7 A++
Pdesign (cooling) kW 10,0
Input power cooling (Nominal) kW 2,62
Input power cooling (Min) kW 0,56
Input power cooling (Max) kW 4,00
Annual energy consumption cooling (3) kWh/a 521
Heating capacity (Nominal) kW 10,0
Heating capacity (Min) kW 3,0
Heating capacity (Max) kW 14,0
COP (Nominal) (1) W/W 4,93
COP (Min) (1) W/W 5,36
COP (Max) (1) W/W 3,59
SCOP/ηsc (2) % 4,4 A+
Pdesign at -10°C kW 10,0
Input power heating (Nominal) kW 2,03
Input power heating (Min) kW 0,56
Input power heating (Max) kW 3,90
Annual energy consumption heating (3) kWh/a 3.182
Indoor unit S-1014PU3E
Indoor air flow (Hi) m³/min 36,0
Indoor air flow (Med) m³/min 26,0
Indoor air flow (Lo) m³/min 18,0
Moisture removal volume L/h 2,7
Indoor sound pressure (Med) (4) dB(A) 38
Indoor sound pressure (Lo) (4) dB(A) 32
Indoor sound power (Hi) dB(A) 60
Indoor sound power (Med) dB(A) 53
Indoor sound power (Lo) dB(A) 47
Indoor dimension (Height) mm 319
Indoor dimension (Width) mm 840
Indoor dimension (Depth) mm 840
Panel dimension (Height) mm 33,5
Panel dimension (Depth) mm 950
Indoor net weight kg 25
Panel net weight kg 5
nanoe X Generator Mark 1
Outdoor unit U-100PZ3E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 4,35
Current in cooling (1p 230V / 3p 400) A 4,15
Current in cooling (1p 240V / 3p 415) A 4,00
Current in heating (1p 220V / 3p 380) A 3,40
Current in heating (1p 230V / 3p 400) A 3,20
Current in heating (1p 240V / 3p 415) A 3,10
Outdoor air flow (Cool) m³/min 73,0
Outdoor air flow (Heat) m³/min 73,0
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 83
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (7) m 15 / 30 (8)
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,40 / 1,62
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

(1) Le calcul des coefficients EER et COP est conforme à la norme européenne EN 14511.
2) Pour les modèles de moins de 12 kW, le SEER et SCOP respectent les valeurs définies dans le règlement délégué UE/626/2011. Pour les modèles de plus de 12 kW, les valeurs ηsc / ηsh respectent les valeurs définies par la directive EN 14825.
3) Réglage en usine.
4) Le niveau de pression sonore des unités indique la valeur mesurée pour une position à 1,5 m en dessous de l’unité. La pression sonore est mesurée conformément à la norme Eurovent 6/C/006-97.
5) Connectez le raccord de tube de liquide (Ø6,35-Ø9,52) au côté du tube de liquide de l’unité intérieure.
6) Connectez le raccord de tube de gaz (Ø12,70-Ø15,88) au côté du tube de gaz de l’unité intérieure.
7) Lors d’installation de l’unité extérieure à une position plus élevée que l’unité intérieure.
8) Unité extérieure placée plus bas/unité extérieure placée plus haut.
* Fusible recommandé pour l’unité intérieure 3A.
** Les valeurs ci-dessous s’appliquent si nanoe™ X est désactivé.