PACI NX Elite - Plafonniers Inverter+ - R32

Les unités de type plafonnier assurent une diffusion de l’air étendue et large, indispensable pour les grandes pièces

La hauteur et la profondeur sont identiques pour les installations mixtes et respectent leur apparence homogène

La dernière génération de climatiseurs pour le tertiaire est arrivée

Caractéristiques

Voir tout
PACI NX Elite - Plafonniers Inverter+ - R32
12.5 kW
Kit KIT-125PT3ZH48
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,1
Cooling capacity (Min) kW 3,2
Cooling capacity (Max) kW 14,0
EER (Nominal) (1) W/W 3,46
EER (Min) (1) W/W 3,01
EER (Max) (1) W/W 5,33
SEER/ηsc (2) % 277,3%
Pdesign (cooling) kW 12,1
Input power cooling (Nominal) kW 3,50
Input power cooling (Min) kW 0,60
Input power cooling (Max) kW 4,65
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 14,0
Heating capacity (Min) kW 3,2
Heating capacity (Max) kW 16,0
COP (Nominal) (1) W/W 3,78
COP (Min) (1) W/W 3,20
COP (Max) (1) W/W 5,52
SCOP/ηsc (2) % 175,6%
Pdesign at -10°C kW 9,5
Input power heating (Nominal) kW 3,70
Input power heating (Min) kW 0,58
Input power heating (Max) kW 5,00
Annual energy consumption heating (3) kWh/a
Indoor unit S-1014PT3E
Indoor air flow (Hi) m³/min 34,0
Indoor air flow (Med) m³/min 28,0
Indoor air flow (Lo) m³/min 24,0
Moisture removal volume L/h 5,4
Indoor sound pressure (Med) (4) dB(A) 40
Indoor sound pressure (Lo) (4) dB(A) 35
Indoor sound power (Hi) dB(A) 64
Indoor sound power (Med) dB(A) 58
Indoor sound power (Lo) dB(A) 53
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
nanoe X Generator Mark 2
Outdoor unit U-125PZH4E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 5,45
Current in cooling (1p 230V / 3p 400) A 5,15
Current in cooling (1p 240V / 3p 415) A 5,00
Current in heating (1p 220V / 3p 380) A 5,10
Current in heating (1p 230V / 3p 400) A 4,80
Current in heating (1p 240V / 3p 415) A 4,65
Outdoor air flow (Cool) m³/min 86,0
Outdoor air flow (Heat) m³/min 78,0
Outdoor sound pressure (Cool -Hi) dB(A) 55
Outdoor sound pressure (Heat -Hi) dB(A) 55
Outdoor sound power (Cool -Hi) dB(A) 73
Outdoor sound power (Heat -Hi) dB(A) 73
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 84
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R32) / CO2 Eq. kg / T 3,00 / 2,03
Operating range (Cool - Min) °C -20 (8)
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) Le calcul de l'EER et du COP est basé sur la norme EN14511.
2) Pour les modèles inférieurs à 12 kW, le SEER et le SCOP sont calculés sur la base des valeurs EU/626/2011. Pour les modèles au-dessus de 12 kW, les valeurs ηs,c / ηs,h sont calculées sur la base de la norme EN 14825.
3) Réglage d'usine.
4) La pression sonore des unités indique la valeur mesurée de la position à 1 m devant le corps principal et à 1 m sous l'unité. La pression sonore est mesurée selon la spécification Eurovent 6/C/006-97.
5) Connectez le tube de prise de liquide (Ø6,35-Ø9,52) à l'unité intérieure côté tube de liquide.
6) Connectez le tube de prise de gaz (Ø12,70-Ø15,88) à l'unité intérieure côté tube de gaz.
7) Unité extérieure située plus bas/unité extérieure située plus haut.
8) Longueur de tuyau jusqu'à 30 m.

* Fusible recommandé pour l'intérieur 3A.
** Les valeurs ci-dessus sont dans le cas de nanoe™ X OFF.

Accessoires