Modeli
Aquarea, an innovative new low-energy system based on Air to Water heat pump technology
Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
The Mono‑Bloc system: This only has an outdoor unit. The installation doesn’t require a refrigerated connection and is only connected to the heating and/or hot water.
A heat pump turns heat energy outside into warmth inside
Specifikacije
| Aquarea High Performance Mono‑bloc J Generation 1 Phase • R32 | JEDNOFAZNO | ||||
|---|---|---|---|---|---|
| 5 kW | 7 kW | 9 kW | |||
| Vanjska jedinica | WH-MDC07J3E5 | WH-MDC09J3E5 | |||
| Kapacitet grijanja (A +7 °C, W 35 °C) | kW | 5,00 | 7,00 | 9,00 | |
| COP (A +7 °C, W 35 °C) | 5,08 | 4,76 | 4,48 | ||
| Kapacitet grijanja (A +7 °C, W 55 °C) | kW | 5,00 | 7,00 | 8,95 | |
| COP (A +7 °C, W 55 °C) | 3,01 | 2,82 | 2,78 | ||
| Kapacitet grijanja (A +2 °C, W 35 °C) | kW | 5,00 | 7,00 | 7,45 | |
| COP (A +2 °C, W 35 °C) | 3,57 | 3,40 | 3,13 | ||
| Kapacitet grijanja (A +2 °C, W 55 °C) | kW | 5,00 | 6,30 | 7,00 | |
| COP (A +2°C, W 55°C) | 2,27 | 2,16 | 2,12 | ||
| Kapacitet grijanja (A -7 °C, W 35 °C) | kW | 5,00 | 6,80 | 7,50 | |
| COP (A -7 °C, W 35 °C) | 2,78 | 2,81 | 2,63 | ||
| Kapacitet grijanja (A -7 °C, W 55 °C) | kW | 5,00 | 6,30 | 7,00 | |
| COP (A -7 °C, W 55 °C) | 1,85 | 1,86 | 1,80 | ||
| Kapacitet hlađenja (A 35°C, W 7°C) | kW | 5,00 | 7,00 | 9,00 | |
| EER (A 35 °C, W 7 °C) | 3,31 | 3,06 | 2,71 | ||
| Kapacitet hlađenja (A 35°C, W 18°C) | kW | 5,00 | 7,00 | 9,00 | |
| EER (A 35°C, W 18°C) | 5,05 | 4,73 | 4,25 | ||
| Zagrijavanje prosječne klime. Sezonska energetska učinkovitost (W 35°C / W 55°C) | ηs % | 202 / 142 | 193 / 130 | 193 / 130 | |
| Zagrijavanje prosječne klime. Sezonska energetska učinkovitost (W 35°C / W 55°C) | SCOP | 5,12 / 3,63 | 4,90 / 3,32 | 4,90 / 3,32 | |
| Zagrijavanje prosječne klime. Energetska klasa (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | A+++ / A++ | A+++ / A++ | |
| Zagrijavanje tople klime. Sezonska energetska učinkovitost (W 35°C / W 55°C) | ηs % | 237 / 165 | 227 / 160 | 227 / 160 | |
| Zagrijavanje tople klime. Sezonska energetska učinkovitost (W 35°C / W 55°C) | SCOP | 6,00 / 4,20 | 5,75 / 4,07 | 5,75 / 4,07 | |
| Zagrijavanje tople klime. Energetska klasa (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | |
| Zagrijavanje hladne klime. Sezonska energetska učinkovitost (W 35°C / W 55°C) | ηs % | 160 / 115 | 164 / 116 | 164 / 116 | |
| Zagrijavanje hladne klime. Sezonska energetska učinkovitost (W 35°C / W 55°C) | SCOP | 4,08 / 2,95 | 4,18 / 2,98 | 4,18 / 2,98 | |
| Zagrijavanje hladne klime. Energetska klasa (W 35°C / W 55°C) (1) | A+++ to D | A++ / A+ | A++ / A+ | A++ / A+ | |
| Opterećenje dijelova napajanja vanjskog zvuka (grijalica) (1) | dB(A) | 59 | 59 | 59 | |
| Puno opterećenje vanjskog zvuka (grijanje) | dB(A) | 64 | 68 | 69 | |
| Puno opterećenje vanjskog zvuka (Cool) | dB(A) | 65 | 67 | 68 | |
| Vanjska dimenzija (visina) | mm | 865 | 865 | 865 | |
| Vanjska dimenzija (Širina) | mm | 1283 | 1283 | 1283 | |
| Vanjska dimenzija (Dubina) | mm | 320 | 320 | 320 | |
| Vanjska neto težina | kg | 99 | 104 | 104 | |
| Rashladno sredstvo (R32) / CO2 Eq. (2) | kg / T | 1,3 / 0,878 | 1,3 / 0,878 | 1,3 / 0,878 | |
| Priključak cijevi za vodu | Inch | R 1¼ | R 1¼ | R 1¼ | |
| Pumpa (broj brzina) | Variable Speed | Variable Speed | Variable Speed | ||
| Pumpa (ulazna snaga Min) | W | 34 | 36 | 39 | |
| Pumpa (unosna snaga Max) | W | 96 | 100 | 108 | |
| Protok vode za grijanje (∆T=5 K. 35 °C) | L/min | 14,30 | 20,10 | 25,80 | |
| Kapacitet integriranog električnog grijača | kW | 3 | 3,00 | 3,00 | |
| Ulazna snaga (grijalica) | kW | 0,99 | 1,47 | 2,01 | |
| Ulazna snaga (Cool) | kW | 1,51 | 2,29 | 3,32 | |
| Struja pokretanja i pokretanja (grijanje) | A | 4,7 | 7,0 | 9,3 | |
| Struja pokretanja i pokretanja (Cool) | A | 7,0 | 10,5 | 14,7 | |
| Struja 1 | A | 12,0 | 17 | 17 | |
| Struja 2 | A | 13 | 13 | 13 | |
| Preporučeni osigurač u zatvorenom prostoru | A | 30 / 15 | 30 / 15 | 30 / 16 | |
| Preporučena veličina kabela, opskrba 1 | mm² | 3 x 1,5 | 3 x 2,5 | 3 x 2,5 | |
| Preporučena veličina kabela, napajanje 2 | mm² | 3 x 1,5 | 3 x 1,5 | 3 x 1,5 | |
| Radni raspon – vanjska temperatura (grijalica) | °C | -20 ~ 35 | -20 ~ 35 | -20 ~ 35 | |
| Radni raspon – vanjska temperatura (Cool) | °C | 10 ~ 43 | 10 ~ 43 | 10 ~ 43 | |
| Izlaz za vodu (grijalica) | °C | 20 ~ 60 | 20 ~ 60 | 20 ~ 60 | |
| Izlaz za vodu (Cool) | °C | 5 ~ 20 | 5 ~ 20 | 5 ~ 20 | |
(1) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
(2) WH-MDC models are hermetically sealed.
EER and COP calculation is based in accordance to EN14511.