15.00kW
SCU-CRC150A08
iCORE SCU-CRC Custom-fit CO₂ Series
Models with high pressure fan for indoor mounting.
Specifications
| iCORE SCU-CRC Custom-fit Series | |||
|---|---|---|---|
| 15.00 kW | |||
| Model | SCU-CRC150A08 | ||
| Compressors | Single compressor | ||
| Refrigerant | R744 | ||
| PED | CAT | II | |
| Application and nominal cooling capacity | MT/LT (kW) | MT (15) / LT (7) | |
| Power supply (Voltage) | V | 380 - 420 | |
| Power supply (Phase) | Three phase | ||
| Power supply (Frequency) | Hz | 50 | |
| MT - Cooling capacity at | . | ||
| ET -15°C, AT 32°C (Min - Max) | kW | 5,9 - 13,5 | |
| ET -15°C, AT 38°C (Min - Max) | kW | 5,2 - 12,6 | |
| ET -15°C, AT 43°C (Min - Max) | kW | 4,8 - 11,5 | |
| ET -10°C, AT 32°C (Min - Max) | kW | 6,8 - 15,2 | |
| ET -10°C, AT 38°C (Min - Max) | kW | 6,0 - 14,0 | |
| ET -10°C, AT 43°C (Min - Max) | kW | 5,5 - 12,8 | |
| ET -5°C, AT 32°C (Min - Max) | kW | 7,7 - 16,8 | |
| ET -5°C, AT 38°C (Min - Max) | kW | 6,8 - 15,4 | |
| ET -5°C, AT 43°C (Min - Max) | kW | 6,2 - 13,9 | |
| LT - Cooling capacity at | . | ||
| ET -35°C, AT 32°C (Min - Max) | kW | 3,0 - 7,3 | |
| ET -35°C, AT 38°C (Min - Max) | kW | 2,9 - 7,0 | |
| ET -35°C, AT 43°C (Min - Max) | kW | — - — | |
| ET -30°C, AT 32°C (Min - Max) | kW | 3,7 - 8,7 | |
| ET -30°C, AT 38°C (Min - Max) | kW | 3,3 - 8,3 | |
| ET -30°C, AT 43°C (Min - Max) | kW | 3,3 - 7,8 | |
| ET -25°C, AT 32°C (Min - Max) | kW | 4,3 - 10,2 | |
| ET -25°C, AT 38°C (Min - Max) | kW | 3,9 - 9,6 | |
| ET -25°C, AT 43°C (Min - Max) | kW | 3,8 - 9,0 | |
| SEPR cooling at ET -10°C AT 32°C | 3,07 | ||
| SEPR freezing at ET -35°C AT 32°C | 1,64 | ||
| Annual electricity consumption at ET -10°C AT 32°C | kWh/a | 30.019 | |
| Annual electricity consumption at ET -35°C AT 32°C | kWh/a | 33.650 | |
| Evaporator connection | Multiple | ||
| Evaporation temperature (Min) | °C | -35 | |
| Evaporation temperature (Max) | °C | 0 | |
| Ambient temperature (Min) | °C | -20 | |
| Ambient temperature (Max) | °C | 43 | |
| PS line (Suction) | bar | 80 | |
| PS line (Liquid) | bar | 80 | |
| User system external alarm. Digital input. Non-voltage contact | Yes | ||
| Liquid tube electromagnetic valve | Vac | — | |
| Showcase operation ON/OFF signal. Digital output. Non-voltage contact | Yes | ||
| Modbus communication line (RS485) | Ports | Accessory | |
| Type of compressors | 2- stage rotary | ||
| Dimension (Width) | mm | 1.326 | |
| Dimension (Height) | mm | 1.724 | |
| Dimension (Depth) | mm | 790 | |
| Net weight | kg | 300 | |
| Connections (Suction) | Inch (mm) | 1/2 (12,70) | |
| Connections (Liquid) | Inch (mm) | 1/2 (12,70) | |
| Length of connection piping | m | 50 | |
| Air flow (Nominal) | m³/h | 1x8.200 | |
| External static pressure | Pa | 120 | |
| Standard performance | . | ||
| Nominal operating current at ET -10°C MT / -30°C LT AT 32°C and 230 - 400V 50Hz | A | 20,6 | |
| Maximum operating current (in the most loaded phase at 230 - 400V 50Hz) | A | 26,0 | |
| Sound level at 10m | dB(A) | 55,0 | |