Wall Mounted Professional -20°C • R32

Complete line-up with high efficiency even at -20°C.

This Wall Mounted air conditioner is especially designed for professional applications such as computer rooms where cooling inside the room is necessary even when the outside temperature is low. Furthermore this air conditioner has an automatic changeover system, in order to maintain the inside temperature even when sharp outside temperature changes occur.

  • Aerowings to control air draft direction
  • Designed for 24h/7d a week operation
  • Up to A+++ in cooling
  • Highly efficient even at -20 °C
  • High durability rolling bearings
  • Additional piping sensors to prevent freezing
  • Automatic restart

Discover the latest generation of air conditioning system

The air conditioning connects with the future

Specifications

See all
Wall Mounted Professional -20°C • R32 Single Phase
2.50 kW 3.50 kW 4.20 kW 5.00 kW 7.10 kW
EER (Nominal) (1) W/W 4,90 (5,00 - 4,29) A 4,07 (5,00 - 3,64) A 3,82 (4,90 - 3,25) A 3,60 (3,50 - 3,09) A 3,17 (2,33 - 3,03) B
COP (Nominal) (1) W/W 4,86 (5,15 - 4,12) A 0,92 (0,17 - 1,82) 4,00 (4,45 - 3,37) A 4,03 (2,88 - 3,20) A 3,51 (2,45 - 3,47) B
Refrigerant (R32) / CO2 Eq. kg / T 0,96 / 0,648 1,00 / 0,675 1,08 / 0,729 1,15 / 0,776 1,32 / 0,891
Kit KIT-Z25-TKEA KIT-Z35-TKEA KIT-Z42-TKEA KIT-Z50-TKEA KIT-Z71-TKEA
Cooling capacity (Nominal) kW KIT-Z25-TKEA KIT-Z35-TKEA KIT-Z42-TKEA KIT-Z50-TKEA KIT-Z71-TKEA
Cooling capacity (Min) kW 2,50 3,50 4,20 5,00 7,10
Cooling capacity (Max) kW 0,85 0,85 0,98 0,98 0,98
EER (Nominal) (1) W/W 3,00 4,00 5,00 6,00 8,10
EER (Min) (1) W/W 4,90 4,07 3,82 3,60 3,17
EER (Max) (1) W/W 5,00 5,00 4,90 3,50 2,33
SEER (2) 8,50 A+++ 8,50 A+++ 8,50 A+++ 8,50 A+++ 6,10 A++
Pdesign (cooling) kW 2,50 3,50 4,20 5,00 7,10
Input power cooling (Nominal) kW 0,51 0,86 1,10 1,39 2,24
Input power cooling (Min) kW 0,17 0,17 0,20 0,28 0,42
Input power cooling (Max) kW 0,70 1,10 1,54 1,94 2,67
Annual energy consumption cooling (3) kWh/a 103 144 173 206 407
Heating capacity (Nominal) kW 3,40 4,00 5,40 5,80 8,60
Heating capacity (Min) kW 0,85 0,85 0,98 0,98 0,98
Heating capacity (Max) kW 5,40 6,60 7,25 8,00 9,90
Heating capacity at -7°C kW 3,33 4,07 4,30 5,00 6,13
COP (Nominal) (1) W/W 4,86 4,35 4,00 4,03 3,51
COP (Min) (1) W/W 5,15 5,15 4,45 2,88 2,45
COP (Max) (1) W/W 4,12 3,63 3,37 3,20 3,47
SCOP (2) 4,50 A+ 4,40 A+ 4,30 A+ 4,40 A+ 4,00 A+
Pdesign at -10°C kW 2,80 3,60 3,80 4,40 5,50
Input power heating (Nominal) kW 0,70 0,92 1,35 1,44 2,45
Input power heating (Min) kW 0,17 0,17 0,22 0,34 0,40
Input power heating (Max) kW 1,31 1,82 2,15 2,50 2,85
Annual energy consumption heating (3) kWh/a 871 1145 1237 1400 1925
Indoor unit CS-Z25TKEA CS-Z35TKEA CS-Z42TKEA CS-Z50TKEA CS-Z71TKEA
Indoor power source V 230 230 230 230 230
Indoor recommended fuse A 16 16 16 16 20
Indoor connection indoor / outdoor mm² 4 x 1,5 4 x 1,5 4 x 1,5 4 x 2,5 4 x 2,5
Indoor air flow (Cool) m³/min 10,4 10,7 18,2 19,2 20,2
Indoor air flow (Heat) m³/min 11,7 12,4 20,2 21,3 21,0
Moisture removal volume L/h 1,5 2,0 2,4 2,8 4,1
Indoor sound pressure (Cool -Hi) (4) dB(A) 39 42 43 44 47
Indoor sound pressure (Cool -Lo) (4) dB(A) 25 28 32 37 38
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 21 21 29 30 35
Indoor sound pressure (Heat -Hi) (4) dB(A) 41 43 44 44 47
Indoor sound pressure (Heat -Lo) (4) dB(A) 27 30 35 37 38
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 22 22 29 30 35
Indoor dimension (Height) mm 295 295 302 302 302
Indoor dimension (Width) mm 919 919 1120 1120 1120
Indoor dimension (Depth) mm 194 194 236 236 236
Indoor net weight kg 9 10 12 12 13
Outdoor unit CU-Z25TKEA CU-Z35TKEA CU-Z42TKEA CU-Z50TKEA CU-Z71TKEA
Outdoor sound pressure (Cool -Hi) (4) dB(A) 46 48 48 48 52
Outdoor sound pressure (Heat -Hi) (4) dB(A) 48 50 50 50 54
Outdoor dimension (Height) (5) mm 619 619 619 695 695
Outdoor dimension (Width) (5) mm 824 824 824 875 875
Outdoor dimension (Depth) (5) mm 299 299 299 320 320
Outdoor net weight kg 37 38 38 43 49
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)  3/8 (9,52)  1/2 (12,70) 1/2 (12,70) 5/8 (15,88)
Pipe length range m 3 ~ 20 3 ~ 20 3 ~ 20 3 ~ 30 3 ~ 30
Elevation difference (in/out) (6) m 15 15 15 15 20
Pipe length for additional gas m 7,5 7,5 7,5 7,5 10,0
Additional gas amount g/m 10 10 10 15 25
Refrigerant (R32) / CO2 Eq. kg / T 0,96 / 0,648 1,00 / 0,675 1,08 / 0,729 1,15 / 0,776 1,32 / 0,891 
Operating range (Cool - Min) °C -20 -20 -20 -20 -20
Operating range (Cool - Max) °C 43 43 43 43 43
Operating range (Heat - Min) °C -15 -15 -15 -15 -15
Operating range (Heat - Max) °C 24 24 24 24 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.

* Only one of these can be used at a time.