Specifications

See all
iCOOL SCU Series – MT THREE PHASE
16.00 kW 19.00 kW
Model SCU-KSC160M08 SCU-KSC190M08
Compressors Tandem compressor Tandem compressor
Compatible refrigerants R448A, R449A, R134a, R513A R448A, R449A, R134a, R513A
PED CAT II II
Application and nominal cooling capacity MT/LT (kW) MT (16,0) MT (19,0)
MT (R449A/R448A) - Cooling capacity at . .
ET -15°C, AT 32°C (Min - Max) kW 2,3 - 13,2 2,3 - 15,2
ET -15°C, AT 38°C (Min - Max) kW 2,1 - 11,8 2,1 - 13,5
ET -15°C, AT 43°C (Min - Max) kW 1,9 - 10,7 — - —
ET -10°C, AT 32°C (Min - Max) kW 2,9 - 16,3 2,9 - 18,7
ET -10°C, AT 38°C (Min - Max) kW 2,6 - 14,6 2,6 - 16,7
ET -10°C, AT 43°C (Min - Max) kW 2,4 - 13,3 2,4 - 15,2
ET -5°C, AT 32°C (Min - Max) kW 3,6 - 19,8 3,6 - 22,7
ET -5°C, AT 38°C (Min - Max) kW 3,2 - 17,9 3,2 - 20,5
ET -5°C, AT 43°C (Min - Max) kW 3,0 - 16,4 3,0 - 18,8
MT (R134a/R513A) - Cooling capacity at . .
ET -15°C; AT 32°C (Min - Max) kW 1,7 - 8,9 1,7 - 10,7
ET -15°C; AT 38°C (Min - Max) kW 1,6 - 8,2 — - —
ET -15°C; AT 43°C (Min - Max) kW — - — — - —
ET -10°C; AT 32°C (Min - Max) kW 2,2 - 10,8 2,2 - 13,1
ET -10°C; AT 38°C (Min - Max) kW 2,0 - 10,0 2,0 - 11,9
ET -10°C; AT 43°C (Min - Max) kW 1,9 - 9,4 1,9 - 11,5
ET -5°C; AT 32°C (Min - Max) kW 2,8 - 13,1 2,8 - 15,6
ET -5°C; AT 38°C (Min - Max) kW 2,6 - 12,2 2,6 - 14,6
ET -5°C; AT 43°C (Min - Max) kW 2,4 - 11,4 2,4 - 14,5
SEPR cooling at ET -10°C AT 32°C 3,14 3,19
SEPR freezing at ET -35°C AT 32°C
Annual electricity consumption at ET -10°C AT 32°C kWh/a 31.411 35.312
Annual electricity consumption at ET -35°C AT 32°C kWh/a
Nominal operating current at ET -10°C MT / -30°C LT AT 32°C and 230 - 400V 50Hz A 23,6 28,7
Maximum operating current (in the most loaded phase at 230 - 400V 50Hz) A 30,5 34,9
Maximum power consumption kW 14,6 17,7
Dimension (Width) mm 1.327 1.327
Dimension (Height) mm 1.558 1.558
Dimension (Depth) mm 745 745
Net weight kg 342 344
Sound level at 10m dB(A) 55,0 55,0
Oil charge dm³ 2,0 + 1,7 + 2x0,4 2,0 + 1,7 + 2x0,4
Connections (Suction) Inch (mm) 1 1/8 1 1/8
Connections (Liquid) Inch (mm) 5/8 5/8
Liquid receiver dm³ 15 15
Length of connection piping m 50 50
Maximum height distance (Evaporator above) m 12 12
Maximum height distance (Evaporator below) m 12 12
Which pipes needs to be insulated (Suction / liquid / both) Suction Suction
Recommended insulation thickness mm 13 13
Maximum quantity of evaporators connected Qty. 10 10
Evaporation temperature (Min) °C -15 -15
Evaporation temperature (Max) °C 10 10
Ambient temperature (Min) °C -20 -20
Ambient temperature (Max) °C 43 43
Condenser . .
Fans x diameter mm 1x560 1x560
Air flow (Nominal) m³/h 9.000 9.000
Fan static pressure Pa 120 80
Fan power supply V / ph / Hz 200 - 277 / 1 / 50 200 - 277 / 1 / 50
Fan power consumption W 1050 1.050
Nominal fan amperage A 4,6 4,6
Compressor - additional data . .
Compressor model C-SBS180H00B/ C-SBN303H8G C-SBS180H00B/ C-SBN453H8G
Volumetric flow m³/h 5,8 - 17,4 / 11,6 5,8 - 17,4 / 14,7
Rotation range rps 32 - 90 32 - 90
Current (Full load amperage) A 14,7 / 8,0 15,2 / 11,9
Current (Peak current limit / Locked rotor amperage) A 34 / 48 34 / 66
Oil type FV68S (PVE) FV68S (PVE)
Crankcase heater power consumption W 2x70 2x70
CU power supply . .
Voltage V / ph / Hz 3x400 / 50 PE+N (TN-S) 3x400 / 50 PE+N (TN-S)
Recommended minimum cable cross-section mm² 5x6,0 5x10,0
Recommended minimum protection C32 C40