PACi NX Series Štandardná nástenná montáž - PK4 - R32

10.0kW

KIT-100PK4Z8 (S-5010PK4E + U-100PZ3E8)

PACi NX Series Štandardná nástenná montáž - PK4 - R32

Štýlové nástenné jednotky s matným povrchom, ideálne pre štúdiá, telocvične, vysoké stropy a serverovne.

Nová generácia komerčných klimatizácií je tu

Špecifikácie

Pozri všetky
PACi NX Series Štandardná nástenná montáž - PK4 - R32
10.0 kW
COP (Min) (1) W/W 3,56
Outdoor air flow (Heat) m³/min 73,0
Outdoor air flow (Cool) m³/min 73,0
nanoe X Generator Značka 3
Moisture removal volume L/h 4,0
Input power heating (Max) kW 2,95
Input power heating (Min) kW 0,56
COP (Max) (1) W/W 5,36
Heating capacity (Max) kW 10,5
Heating capacity (Min) kW 3,0
Annual energy consumption cooling (3) kWh/a 508
Input power cooling (Max) kW 3,10
Input power cooling (Min) kW 0,56
Input power cooling (Nominal) kW 2,79
Pdesign (cooling) kW 9,0
EER (Max) (1) W/W 5,36
EER (Min) (1) W/W 3,13
Current in heating (1p 220V / 3p 380) A 3,95
Indoor sound pressure (Lo) (5) dB(A) 41
Indoor sound pressure (Med) (5) dB(A) 45
Indoor sound pressure (Hi) (5) dB(A) 49
Indoor air flow (Lo) m³/min 17,5
Indoor air flow (Med) m³/min 20,0
Indoor air flow (Hi) m³/min 22,5
Indoor sound power (Lo) dB(A) 57
Indoor sound power (Med) dB(A) 61
Current in heating (1p 240V / 3p 415) A 3,60
Current in heating (1p 230V / 3p 400) A 3,75
Cooling capacity (Max) kW 9,7
Current in cooling (1p 240V / 3p 415) A 4,25
Current in cooling (1p 230V / 3p 400) A 4,45
Current in cooling (1p 220V / 3p 380) A 4,65
Remote controller CZ-RTC5B
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound pressure (Heat - Hi) dB(A) 52
Outdoor sound pressure (Cool - Hi) dB(A) 52
Elevation difference (in/out) (8) m 15 / 30
Indoor net weight kg 14
Heating capacity (Nominal) kW 9,0
Cooling capacity (Nominal) kW 9,0
Operating range (Cool - Min) °C -10
Input power heating (Nominal) kW 2,36
Pdesign at -10°C kW 8,8
SCOP (2) 4,0 A+
Annual energy consumption heating (3) kWh/a 3.080
SEER (2) 6,2 A++
Outdoor net weight kg 83
Outdoor dimension (Height) mm 996
Outdoor power source V 380 - 400 - 415
Indoor dimension (Height) mm 295
Pipe length range m 5 ~ 50
Piping diameter (Gas) Inch (mm) 5/8 (15,88)
Cooling capacity (Min) kW 3,0
Operating range (Heat - Max) °C +24
Operating range (Heat - Min) °C -15
Operating range (Cool - Max) °C +43
Outdoor unit U-100PZ3E8
Indoor unit S-5010PK4E
Kit KIT-100PK4Z8
Additional gas amount g/m 2,4 / 1,62
Pre-charged pipe length m 30
Piping diameter (Liquid) Inch (mm) 3/8 (9,52)
Outdoor dimension (Depth) mm 370
Outdoor dimension (Width) mm 980
Indoor dimension (Depth) mm 249
Indoor dimension (Width) mm 1.060
Refrigerant (R32) / CO2 Eq. kg / T 45
Indoor sound power (Hi) dB(A) 65
EER (Nominal) (1) W/W 3,23
COP (Nominal) (1) W/W 3,81

1) Výpočet EER a COP vychádza z normy EN 14511.
2) Pri modeloch s výkonom nižším ako 12 kW sa SEER a SCOP vypočítava na základe hodnôt EÚ/626/2011. Pre modely nad 12 kW sa hodnoty ηs,c / ηs,h vypočítavajú na základe normy EN 14825.
3) Nastavenie z výroby.
4) Hodnota je založená na interpolácii.
5) Akustický tlak jednotiek zobrazuje hodnotu nameranú z pozície 1 m pred hlavným telesom a 1 m pod jednotkou. Akustický tlak sa meria v súlade so špecifikáciou Eurovent 6/C/006-97.
6) Pripojte rúrku kvapalinovej zásuvky (Ø6,35-Ø9,52) k vnútornej jednotke na strane kvapalinovej rúrky.
7) Pripojte plynovú zásuvkovú rúrku (Ø12,70-Ø15,88) k vnútornej jednotke na strane plynovej rúrky.
8) Vonkajšia jednotka umiestnená nižšie / vonkajšia jednotka umiestnená vyššie.
* Odporúčaná poistka pre vnútornú jednotku 3A.
** Uvedené hodnoty sú v prípade nanoe™ X OFF.

Doplnkové Produkty

Čo sa deje