2-rúrková kombinácia ECOi EX ME2 s úsporou miesta od 22 do 80 HP

42kW

U-10ME2E8 + U-16ME2E8 + U-16ME2E8

Systém VRF s úsporným výkonom, výkonnou prevádzkou, spoľahlivosťou a komfortom, ktorý prekonáva všetky doterajšie možnosti

Predstavuje skutočnú zmenu paradigmy v oblasti klimatizačných riešení.

Špecifikácie

Pozri všetky
2-rúrková kombinácia ECOi EX ME2 s úsporou miesta od 22 do 80 HP
42 kW
Piping diameter (Gas) (3) Inch (mm) 1-1/2 (38,10) / 1-5/8 (41,28) 
Piping diameter (Balance) (3) Inch (mm) 1/4 (6,35)
Piping diameter (Liquid) (3) Inch (mm) 3/4 (19,05) / 7/8 (22,22)
Sound power (Normal mode) dB(A) 86,0
Sound pressure (Silent mode 1) dB(A) 62,0
SCOP (2) 4,11
Power supply (Phase) Three phase
Power supply (Voltage) V 380 - 400 - 415
Dimension (Depth) mm 1.000
Dimension (Width) mm 3.250
Dimension (Height) mm 1.842
Refrigerant (R410A) / CO2 Eq. kg / T 22,20 / 46,3536
Net weight kg 840
Heating capacity (Nominal) kW 132,0
Cooling capacity (Nominal) kW 118,0
Operating range (Cool - Min) °C -10
Power supply (Frequency) Hz 50
SEER (2) 6,57
Current in cooling (1p 230V / 3p 400) A 50,20
Sound pressure (Normal mode) dB(A) 65,0
External static pressure (Max) Pa 80
HP 42HP
Maximum allowable indoor / outdoor capacity ratio (4) % 50 ~ 130 (200)
Air flow m³/min 688
Starting current A 5,00
Current in heating (1p 240V / 3p 415) A 44,90
Current in heating (1p 230V / 3p 400) A 46,60
Current in heating (1p 220V / 3p 380) A 49,10
Current in cooling (1p 240V / 3p 415) A 48,40
Current in cooling (1p 220V / 3p 380) A 52,80
Input power heating kW 29,40
Input power cooling kW 32,0
EER (1) W/W 3,69
COP (1) W/W 4,49
Operating range (Heat - Max) °C +18
Operating range (Heat - Min) °C -25
Operating range (Cool - Max) °C +52
Outdoor unit U-10ME2E8 + U-16ME2E8 + U-16ME2E8
Refrigerant (R410A) / CO2 Eq. kg / T 22,20 / 46,3536
Operating range (Heat - Max) °C +18
Operating range (Heat - Min) °C -25
Operating range (Cool - Max) °C +52
Outdoor unit U-10ME2E8 + U-16ME2E8 + U-16ME2E8
Power supply (Frequency) Hz 50
Power supply (Phase) Three phase
Power supply (Voltage) V 380 - 400 - 415
Dimension (Depth) mm 1.000
Dimension (Width) mm 3.250
Dimension (Height) mm 1.842
COP (1) W/W 4,49
Net weight kg 840
Heating capacity (Nominal) kW 132,0
Cooling capacity (Nominal) kW 118,0
Operating range (Cool - Min) °C -10
Starting current A 5,00
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 130 (200)
Piping diameter (Gas) (2) Inch (mm) 1-1/2 (38,10) / 1-5/8 (41,28) 
Piping diameter (Balance) (2) Inch (mm) 1/4 (6,35)
Piping diameter (Liquid) (2) Inch (mm) 3/4 (19,05) / 7/8 (22,22) 
Sound power (Normal mode) dB(A) 86,0
Sound pressure (Silent mode 1) dB(A) 62,0
Sound pressure (Normal mode) dB(A) 65,0
External static pressure (Max) Pa 80
HP 42HP
Air flow m³/min 688
Current in heating (1p 240V / 3p 415) A 44,90
Current in heating (1p 230V / 3p 400) A 46,60
Current in heating (1p 220V / 3p 380) A 49,10
Current in cooling (1p 240V / 3p 415) A 48,40
Current in cooling (1p 230V / 3p 400) A 50,20
Current in cooling (1p 220V / 3p 380) A 52,80
Input power heating kW 29,40
Input power cooling kW 32,0
EER (1) W/W 3,69

1) Výpočet EER a COP je založený na norme EN14511.
2) SEER/SCOP sa vypočítava na základe hodnôt sezónnej účinnosti chladenia/vykurovania priestoru "η" podľa NARIADENIA KOMISIE (EÚ) 2016/2281. SEER, SCOP = (η + korekcia) × PEF.
3) Priemer potrubia pod 90 m pre konečnú vnútornú jednotku / nad 90 m pre konečnú vnútornú jednotku (ak najdlhšia ekvivalentná dĺžka potrubia presahuje 90 m, zväčšite rozmery hlavných rúrok o 1 stupeň pre plynové a kvapalinové rúrky).
4) Ak sú splnené nasledujúce podmienky, účinný rozsah je nad 130 % a pod 200 %: A. Dodržujte obmedzený počet pripojiteľných vnútorných jednotiek. B. Spodná hranica prevádzkového rozsahu pre vonkajšiu teplotu vykurovania je obmedzená na -10 °C WB (štandardne -25 °C WB). C. Súčasná prevádzka je obmedzená na menej ako 130 % pripojiteľných vnútorných jednotiek.