Aquarea High Performance Bi-bloc H Generation 1 Phase • R410A Monophasé
7 kW 3 kW 5 kW 7 kW 9 kW 12 kW 16 kW
Kit KIT-WC03H3E5 KIT-WC05H3E5 KIT-WC07H3E5 KIT-WC09H3E5 KIT-WC12H6E5 KIT-WC16H6E5
Heating capacity (A +7°C, W 35°C) kW 3,20 5,00 7,00 9,00 12,00 16,00
COP (A +7°C, W 35°C) 5,00 4,63 4,46 4,13 4,74 4,28
Heating capacity (A +7°C, W 55°C) kW 3,20 5,00 6,80 8,90 12,00 14,50
COP (A +7°C, W 55°C) 2,67 2,65 2,63 2,41 2,88 2,68
Heating capacity (A +2°C, W 35°C) kW 3,20 4,20 6,55 6,70 11,40 13,00
COP (A +2°C, W 35°C) 3,56 3,11 3,34 3,13 3,44 3,28
Heating capacity (A +2°C, W 55°C) kW 3,20 4,10 6,00 6,00 9,10 9,80
COP (A +2°C, W 55°C) 2,15 1,98 1,99 1,99 2,20 2,17
Heating capacity (A -7°C, W 35°C) kW 3,20 4,20 5,15 5,90 10,00 11,40
COP (A -7°C, W 35°C) 2,69 2,59 2,68 2,52 2,73 2,57
Heating capacity (A -7°C, W 55°C) kW 3,20 3,55 4,80 5,80 8,20 9,00
COP (A -7°C, W 55°C) 1,72 1,71 1,89 1,88 1,92 1,82
Cooling capacity (A 35°C, W 7°C) kW 3,20 4,50 6,00 7,00 10,00 12,20
EER (A 35°C, W 7°C) 3,08 2,69 2,63 2,43 2,81 2,56
Cooling capacity (A 35°C, W 18°C) kW 3,30 5,00 6,00 7,00 10,00 12,20
EER (A 35°C, W 18°C) 3,75 3,76 3,57 3,26 4,17 4,12
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 130 195 / 130 190 / 130 190 / 130 190 / 134 190 / 130
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,95 / 3,33 4,95 / 3,33 4,83 / 3,33 4,83 / 3,33 4,83 / 3,43 4,83 / 3,33
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 244 / 163 244 / 163 225 / 160 225 / 160 245 / 159 245 / 169
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,18 / 4,15 6,18 / 4,15 5,70 / 4,08 5,70 / 4,08 6,20 / 4,05 6,20 / 4,30
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 150 / 103 150 / 103 160 / 115 160 / 115 168 / 121 168 / 121
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 3,83 / 2,65 3,83 / 2,65 4,08 / 2,95 4,08 / 2,95 4,28 / 3,10 4,28 / 3,10
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+ A++ / A+ A++ / A+ A++ / A+ A++ / A+
Indoor unit WH-SDC03H3E5-1 WH-SDC05H3E5-1 WH-SDC07H3E5-1 WH-SDC09H3E5-1 WH-SDC12H6E5 WH-SDC16H6E5
Indoor sound pressure (Heat) dB(A) 28 28 30 30 33 33
Indoor sound pressure (Cool) dB(A) 28 28 30 30 33 33
Indoor dimension (Height) mm 892 892 892 892 892 892
Indoor dimension (Width) mm 500 500 500 500 500 500
Indoor dimension (Depth) mm 340 340 340 340 340 340
Indoor net weight kg 44 44 44 44 44 45
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed
A class pump (Input power Min) W 30 33 34 40 34 30
A class pump (Input power Max) W 100 106 114 120 110 105
Heating water flow (∆T=5 K. 35°C) L/min 9,20 14,30 20,10 25,80 34,40 45,90
Capacity of integrated electric heater kW 3,00 3,00 3,00 3,00 6,00 6,00
Indoor recommended fuse A 15 / 30 15 / 30 15 / 30 15 / 30 30 / 30  30 / 30 
Recommended cable size, supply 1 mm² 3 x 1,5 3 x 1,5 3 x 1,5 3 x 1,5 3 x 4,0 or 6,0 3 x 4,0 or 6,0
Recommended cable size, supply 2 mm² 3 x 1,5 3 x 1,5 3 x 1,5 3 x 1,5 3 x 4,0 3 x 4,0
Outdoor unit WH-UD03HE5-1 WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1 WH-UD12HE5 WH-UD16HE5
Outdoor sound power part load (Heat) (3) dB(A) 55 55 59 59 65 65
Outdoor sound power full load (Heat) dB(A) 64 65 68 69 69 72
Outdoor sound power full load (Cool) dB(A) 65 66 66 68 68 72
Outdoor dimension (Height) mm 622 622 795 795 1340 1340
Outdoor dimension (Width) mm 824 824 900 900 900 900
Outdoor dimension (Depth) mm 298 298 320 320 320 320
Outdoor net weight kg 39 39 66 66 101 101
Refrigerant (R410A) / CO2 Eq. kg / T 1,20 / 2,506 1,20 / 2,506 1,45 / 3,028 1,45 / 3,028 2,55 / 5,324 2,55 / 5,324
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 40 3 ~ 40 3 ~ 50 3 ~ 50
Elevation difference (in/out) m 5 5 30 30 30 30
Pipe length for additional gas m 10 10 10 10 10 10
Additional gas amount g/m 20 20 30 30 50 50
Operation range (Outdoor ambient) °C -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35
Water outlet (Heat) °C 20 ~ 55 20 ~ 55 20 ~ 55 20 ~ 55 20 ~ 55 20 ~ 55
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20

(1) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
EER and COP calculation is based in accordance to EN14511.

Accessoires