Aquarea Air Smart ventilatorkonvektor gulvstående

Tidligere egenskab Næste kapacitet

3.71kW

P-FAL40

Aquarea Air Smart ventilatorkonvektor gulvstående

Aquarea Air Smart fancoils er designet til at levere både varme og køling i én kompakt enhed og maksimerer energibesparelserne, når de kombineres med en Aquarea varmepumpe.

Specifikationer

Se alle
Aquarea Air Smart ventilatorkonvektor gulvstående
3.71 kW
Model P-FAL40
Fan speed (1) Min / Med / Max
Total cooling capacity (Min) (2) kW 1,36
Total cooling capacity (Med) (2) kW 2,57
Total cooling capacity (Max) (2) kW 3,71
Sensible capacity (Min) (2) kW 1,05
Sensible capacity (Med) (2) kW 1,98
Sensible capacity (Max) (2) kW 2,90
Water flow cooling (Min) (2) l/h
Water flow cooling (Med) (2) l/h
Water flow cooling (Max) (2) l/h
Water pressure drop cooling (Min) (2) kPa
Water pressure drop cooling (Med) (2) kPa
Water pressure drop cooling (Max) (2) kPa
Heating capacity (Min) (3) kW 1,47
Heating capacity (Med) (3) kW 2,78
Heating capacity (Max) (3) kW 4,23
Water flow heating (Min) (3) l/h
Water flow heating (Med) (3) l/h
Water flow heating (Max) (3) l/h
Water pressure drop heating (Min) (3) kPa
Water pressure drop heating (Med) (3) kPa
Water pressure drop heating (Max) (3) kPa
Sound levels .
Sound power (Min) dB(A) 37
Sound power (Med) dB(A) 48
Sound power (Max) dB(A) 58
Sound pressure (Min) (4) dB(A) 28
Sound pressure (Med) (4) dB(A) 38
Sound pressure (Max) (4) dB(A) 47
Ventilation .
Number of fans 1
Air flow (Min) m³/h 364
Air flow (Med) m³/min 479
Air flow (Max) m³/h 663
Single zone air flow (Min) m³/h 13
Electrical data .
Power supply (Voltage) V 230
Power supply (Phase) 1
Power supply (Frequency) Hz 50
Consumption (Min) W
Fan coils water connections .
Hydraulic connections type Eurokonus
Hydraulic connections Inch ¾
Dimensions and weight .
Dimension (Height) mm 580
Dimension (Width) mm 1.480
Dimension (Depth) mm 119
Net weight kg 23

1) Ventilatorens standardhastigheder er indstillet fra fabrikken.
2) I henhold til Eurovent-standarden. Luft: 27°C DB/19°C WB, kølet vand: 7°C/12°C (for data om vandtrykfald: tryktab ved tilsvarende nominelt flow).
3) I henhold til Eurovent-standard. Luft: 20 °C, varmt vand: 45°C/40°C. Tryktab ved tilsvarende nominelt flow (for data om vandtrykfald: tryktab ved tilsvarende nominelt flow).
4) Informative data, der tager højde for en hypotetisk lyddæmpning af rummet og installationen på 9 dB(A).