10.0 kW. PACi Elite Low Static Pressure Hide Away • R410A

KIT-100PN1E5C (S-100PN1E5B + U-100PE1E5A)

The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.

  • Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required. S-60/71/100/125/140PN1E5B models only)
  • Compact indoor units without loosing static pressure (only 250 mm high)
  • 50 Pa static pressure
  • Easy maintenance and service via external electrical box
  • 3 speed centrifugal fan through wired or Infrared remote controller
  • DC FAN for better efficiency and control
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Tehnični podatki

Poglej vse
PACi Elite Low Static Pressure Hide Away • R410A SINGLE PHASE
10.0 kW
EER (Nominal) (1) W/W 3,75 (3,79 - 3,29) A
COP (Nominal) (1) W/W 3,80 (4,18 - 3,11) A
Kit KIT-100PN1E5C
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 10,00
Cooling capacity (Min) kW 3,30
Cooling capacity (Max) kW 12,50
EER (Nominal) (1) W/W 3,75
EER (Min) (1) W/W 3,79
EER (Max) (1) W/W 3,29
SEER (2) 5,90 A+
Pdesign (cooling) kW 10,00
Input power cooling (Nominal) kW 2,67
Input power cooling (Min) kW 0,87
Input power cooling (Max) kW 3,80
Annual energy consumption cooling (3) kWh/a 583
Heating capacity (Nominal) kW 11,20
Heating capacity (Min) kW 4,10
Heating capacity (Max) kW 14,00
Heating capacity at -7°C (2) kW 12,04
Heating capacity at -15°C (2) kW
COP (Nominal) (1) W/W 3,80
COP (Min) (1) W/W 4,18
COP (Max) (1) W/W 3,11
SCOP (2) 3,90 A
Pdesign at -10°C kW 10,00
Input power heating (Nominal) kW 2,95
Input power heating (Min) kW 0,98
Input power heating (Max) kW 4,50
Annual energy consumption heating (3) kWh/a 3590
Indoor unit S-100PN1E5B
External static pressure (Nominal) (5) Pa 40
External static pressure (Min) (5) Pa 10
External static pressure (Max) (5) Pa 80
Indoor air flow (Hi) m³/min 36,00
Indoor air flow (Med) m³/min 33,00
Indoor air flow (Lo) m³/min 26,00
Indoor sound pressure (Hi) (6) dB(A) 44
Indoor sound pressure (Med) (6) dB(A) 42
Indoor sound pressure (Lo) (6) dB(A) 37
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1200
Indoor dimension (Depth) mm 650
Indoor net weight kg 41
Outdoor unit U-100PE1E5A
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 25,00
Current in cooling (1p 230V / 3p 400) A 4,00
Current in cooling (1p 240V / 3p 415) A 11,60
Current in heating (1p 220V / 3p 380) A 11,20
Current in heating (1p 230V / 3p 400) A 10,90
Current in heating (1p 240V / 3p 415) A 12,80
Outdoor air flow (Cool) m³/min 12,50
Outdoor air flow (Heat) m³/min 12,20
Outdoor sound pressure (Cool -Hi) dB(A) 110
Outdoor sound pressure (Heat -Hi) dB(A) 95
Outdoor sound power (Cool -Hi) dB(A) 52
Outdoor sound power (Heat -Hi) dB(A) 52
Outdoor dimension (Height) mm 1416
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 98
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 75
Elevation difference (in/out) (7) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 50
Refrigerant (R410A) / CO2 Eq. kg / T 3,40 / 7,0992
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) Medium external static pressure setting from factory.
(6) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(7) Add 100 mm for piping port.
(8) When installing the outdoor unit at a higher position than the indoor unit. * Recommended fuse for the indoor 3 A.