6.0 kW. PACi Elite Low Static Pressure Hide Away • R410A

KIT-60PN1E5C (S-60PN1E5B + U-60PE2E5A)

The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.

  • Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required. S-60/71/100/125/140PN1E5B models only)
  • Compact indoor units without loosing static pressure (only 250 mm high)
  • 50 Pa static pressure
  • Easy maintenance and service via external electrical box
  • 3 speed centrifugal fan through wired or Infrared remote controller
  • DC FAN for better efficiency and control
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Tehnični podatki

Poglej vse
PACi Elite Low Static Pressure Hide Away • R410A SINGLE PHASE
6.0 kW
EER (Nominal) (1) W/W 3,24 (5,00 - 2,78) A
COP (Nominal) (1) W/W 3,74 (5,14 - 3,64) A
Kit KIT-60PN1E5C
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,00
Cooling capacity (Min) kW 2,00
Cooling capacity (Max) kW 7,10
EER (Nominal) (1) W/W 3,24
EER (Min) (1) W/W 5,00
EER (Max) (1) W/W 2,78
SEER (2) 5,50 A
Pdesign (cooling) kW 6,00
Input power cooling (Nominal) kW 1,85
Input power cooling (Min) kW 0,40
Input power cooling (Max) kW 2,55
Annual energy consumption cooling (3) kWh/a 382
Heating capacity (Nominal) kW 7,00
Heating capacity (Min) kW 1,80
Heating capacity (Max) kW 8,00
Heating capacity at -7°C (2) kW
Heating capacity at -15°C (2) kW
COP (Nominal) (1) W/W 3,74
COP (Min) (1) W/W 5,14
COP (Max) (1) W/W 3,64
SCOP (2) 3,80 A
Pdesign at -10°C kW 5,60
Input power heating (Nominal) kW 1,87
Input power heating (Min) kW 0,35
Input power heating (Max) kW 2,20
Annual energy consumption heating (3) kWh/a 2061
Indoor unit S-60PN1E5B
External static pressure (Nominal) (5) Pa 25
External static pressure (Min) (5) Pa 10
External static pressure (Max) (5) Pa 80
Indoor air flow (Hi) m³/min 22,00
Indoor air flow (Med) m³/min 20,00
Indoor air flow (Lo) m³/min 16,00
Indoor sound pressure (Hi) (6) dB(A) 43
Indoor sound pressure (Med) (6) dB(A) 41
Indoor sound pressure (Lo) (6) dB(A) 36
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1000
Indoor dimension (Depth) mm 650
Indoor net weight kg 32
Outdoor unit U-60PE2E5A
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A
Current in cooling (1p 230V / 3p 400) A
Current in cooling (1p 240V / 3p 415) A 8,60
Current in heating (1p 220V / 3p 380) A 8,30
Current in heating (1p 230V / 3p 400) A 7,90
Current in heating (1p 240V / 3p 415) A 8,75
Outdoor air flow (Cool) m³/min 8,35
Outdoor air flow (Heat) m³/min 8,00
Outdoor sound pressure (Cool -Hi) dB(A) 38
Outdoor sound pressure (Heat -Hi) dB(A) 41
Outdoor sound power (Cool -Hi) dB(A) 46
Outdoor sound power (Heat -Hi) dB(A) 49
Outdoor dimension (Height) mm 619
Outdoor dimension (Width) mm 799
Outdoor dimension (Depth) mm 299
Outdoor net weight kg 40
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (7) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R410A) / CO2 Eq. kg / T 1,95 / 4,0716
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) Medium external static pressure setting from factory.
(6) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(7) Add 100 mm for piping port.
(8) When installing the outdoor unit at a higher position than the indoor unit. * Recommended fuse for the indoor 3 A.