Stenska naprava PACi Elite • R32

Enote iz serije so primerne za uporabo v studiih, telovadnicah, prostorih z visokimi stropi in celo v prostorih z računalniškimi strežniki.

Kompaktnost enote in ploska čelna plošča zagotavljata diskretno vgradnjo, tudi na majhnem prostoru.

Tehnični podatki

Poglej vse
Stenska naprava PACi Elite • R32
9.5 kW
Kit KIT-100PK2ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 9,5
Cooling capacity (Min) kW 3,1
Cooling capacity (Max) kW 10,5
EER (Nominal) (1) W/W 3,26
SEER (2) 6,4 A++
Pdesign (cooling) kW 9,5
Input power cooling (Nominal) kW 2,91
Annual energy consumption cooling (3) kWh/a 520
Annual energy consumption cooling (3) kWh/a 520
Heating capacity (Nominal) kW 9,5
Heating capacity (Min) kW 3,1
Heating capacity (Max) kW 11,5
COP (Nominal) (1) W/W 3,97
SCOP (2) 4,1 A+
Pdesign at -10°C kW 8,0
Input power heating (Nominal) kW 2,39
Annual energy consumption heating (3) kWh/a 2732
Indoor unit S-100PK2E5B
Indoor air flow (Hi) m³/min 22,0
Indoor air flow (Med) m³/min 18,5
Indoor air flow (Lo) m³/min 15,0
Indoor sound pressure (Med) (4) dB(A) 45
Indoor sound pressure (Lo) (4) dB(A) 41
Indoor dimension (Height) mm 302
Indoor dimension (Width) mm 1120
Indoor dimension (Depth) mm 236
Indoor net weight kg 14
Outdoor unit U-100PZH2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 13,50
Current in cooling (1p 230V / 3p 400) A 12,90
Current in cooling (1p 240V / 3p 415) A 12,40
Current in heating (1p 220V / 3p 380) A 11,10
Current in heating (1p 230V / 3p 400) A 10,60
Current in heating (1p 240V / 3p 415) A 10,10
Outdoor air flow (Cool) m³/min 118
Outdoor air flow (Heat) m³/min 108
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 69
Outdoor sound power (Heat -Hi) dB(A) 69
Outdoor dimension (Height) mm 1416
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 99
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 85
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 3,05 / 2,059
Operating range (Cool - Min) °C -20 (6)
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) Izračun EER in COP je izdelan na podlagi EN14511.
(2) Lestvica energijskih nalepk od A+++ do D. Za modele z manj kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/626/2011. Za modele z več kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/2281/2016.
(3) Letna poraba energije je izračunana v skladu z direktivo EU/626/2011.
(4) Zvočni tlak enot prikazuje vrednost, izmerjeno 1 meter pred glavnim ohišjem in 1 meter pod enoto. Zvočni tlak je izmerjen v skladu s tehničnimi navedbami v dokumentu Eurovent 6/C/006-97.
(5) Pri nameščanju zunanje enote na višji položaj od notranje enote.
(6) Modeli 100–140PZH2E5(8) lahko v računalniških prostorih delujejo pri temperaturi do –20 °C z dolžino cevi 30 m ali manj.
* Priporočena jakost varovalke za notranjo enoto je 3 A.

Dopolnilni izdelki