12.5 kW. 4-smerna naprava PACi Elite 90 x 90 • R410A

KIT-125PU2E5D (S-125PU2E5B + U-125PE1E5A)

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Enota PACi visoke zmogljivosti. Zaupanja vredni moč in visoka učinkovitost.

<span style="font-family: Roboto, -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, "Helvetica Neue", Arial, sans-serif, "Apple Color Emoji", "Segoe UI Emoji", "Segoe UI Symbol", "Noto Color Emoji"; font-size: 0.8125rem;">Po zaslugi napredkov v zasnovi in tehnologiji, kot so denimo visokozmogljivi, učinkovitejši in tihi turbo ventilator, sistem za čiščenje zraka nanoe™ X za bolj zdrav zrak ter tipalo temperature tal in tipalo vlažnosti za več nadzora, ponuja nova Panasonicova 4-smerna kasetna naprava U2 90 x 90 velike energijske prihranke, svež zrak in udobje.

  • Visokozmogljiv turbo ventilator, sistem s potekom napeljave za toplotni izmenjevalnik
  • nanoe™ X za izboljšanje kakovosti zraka v zaprtem prostoru
  • Econavi: pametno tipalo za zmanjšano porabo energije
  • Preprosta podporna aplikacija Datanavi z daljinskim upravljalnikom (CZ-RTC5B)
  • Nižja raven hrupa in nizki obrati ventilatorja
  • Majhna teža, preprosta napeljava cevi
  • Črpalka za odtok je del kompleta.

Vnos naravnega ravnovesja v prostor

Tehnični podatki

Poglej vse
4-smerna naprava PACi Elite 90 x 90 • R410A Single Phase
12.5 kW
EER (Nominal) (1) W/W 3,70 (4,29 - 3,04) A
COP (Nominal) (1) W/W 4,60 (5,19 - 3,17)
Kit KIT-125PU2E5D
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,50
Cooling capacity (Min) kW 3,30
Cooling capacity (Max) kW 14,00
EER (Nominal) (1) W/W 3,70
EER (Min) (1) W/W 4,29
EER (Max) (1) W/W 3,04
SEER (2) 6,91
Pdesign (cooling) kW 12,50
Input power cooling (Nominal) kW 3,37
Input power cooling (Min) kW 0,77
Input power cooling (Max) kW 4,60
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 14,00
Heating capacity (Min) kW 4,10
Heating capacity (Max) kW 16,00
COP (Nominal) (1) W/W 4,60
COP (Min) (1) W/W 5,19
COP (Max) (1) W/W 3,17
SCOP (2) 4,10
Pdesign at -10°C kW 12,50
Input power heating (Nominal) kW 3,04
Input power heating (Min) kW 0,79
Input power heating (Max) kW 5,04
Annual energy consumption heating (3) kWh/a
Indoor unit S-125PU2E5B
Indoor air flow (Hi) m³/min 37,00
Indoor air flow (Med) m³/min 27,00
Indoor air flow (Lo) m³/min 19,00
Indoor sound pressure (Hi) (5) dB(A) 46
Indoor sound pressure (Med) (5) dB(A) 39
Indoor sound pressure (Lo) (5) dB(A) 33
Indoor dimension (Height) mm 319
Indoor dimension (Width) mm 840
Indoor dimension (Depth) mm 840
Panel dimension (Height) mm 33,5
Panel dimension (Depth) mm 950
Indoor net weight kg 25
Panel net weight kg 5
nanoe X Generator Mark 1
Outdoor unit U-125PE1E5A
Outdoor power source V 220 - 230 - 240
Outdoor recommended fuse A 30
Outdoor connection indoor / outdoor mm² 6,0
Current in cooling (1p 220V / 3p 380) A 15,20
Current in cooling (1p 230V / 3p 400) A 14,70
Current in cooling (1p 240V / 3p 415) A 14,30
Current in heating (1p 220V / 3p 380) A 13,70
Current in heating (1p 230V / 3p 400) A 13,30
Current in heating (1p 240V / 3p 415) A 12,90
Outdoor air flow (Cool) m³/min 130
Outdoor air flow (Heat) m³/min 110
Outdoor sound pressure (Cool -Hi) dB(A) 53
Outdoor sound pressure (Heat -Hi) dB(A) 53
Outdoor dimension (Height) mm 1416
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 98
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 75
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 50
Refrigerant (R410A) / CO2 Eq. kg / T 3,40 / 7,0992
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

(1) Izračun EER in COP je izdelan na podlagi EN14511.
(2) Lestvica energijskih nalepk od A+++ do D. Za modele z manj kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/626/2011. Za modele z več kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/2281/2016.
(3) Letna poraba energije je izračunana v skladu z direktivo EU/626/2011.
(4) Zmogljivost ogrevanja je izračunana ob upoštevanju korekcije za faktor odmrzovanja.
(5) Zvočni tlak enot prikazuje vrednost, izmerjeno 1,5 m pod enoto. Zvočni tlak je izmerjen v skladu s tehničnimi navedbami v dokumentu Eurovent 6/C/006-97.
(6) Pri nameščanju zunanje enote na višji položaj od notranje enote. * Priporočena jakost varovalke za notranjo enoto je 3 A.