Vse v enem 185L DHW tanku serije K 1 faza · R32

Prejšnja zmogljivost Naslednja zmogljivost

3kW

KIT-ADC03K3E5 (WH-ADC0309K3E5 + WH-UDZ03KE5 / KIT-ADC03K6E5 (WH-ADC0309K6E5 + WH-UDZ03KE5)

Visoka zmogljivost Aquarea Vse v enem 185L DHW tanku K Series 1 faza · R32

Revolucija v oblikovanju, učinkovitosti, povezljivosti in trajnosti.
Aquarea K Series je prelomni nizkoenergijski sistem za ogrevanje, hlajenje in proizvodnjo sanitarne tople vode, ki zagotavlja izjemno zmogljivost. Ta model je idealen za nove instalacije in dobro izolirane domove.
Izjemna učinkovitost in prihranek energije z minimalnim CO2 emisij in minimalnega prostora.
Vrhunska bela, zvesta duhu Aquarea, podčrtana z brezhibno integriranim krmilnikom, ki zagotavlja eleganten črn pas po vsej enoti. Model All in One ohranja svojo kompaktnost s samo 598 x 600 mm, primerljivo z gospodinjskim aparatom.
Zunanje enote z barvo Anthracite Grey, ki bo oblekla celotno paleto, so bile popolnoma preoblikovane z inovativnim dizajnom, ki bo našel svoje mesto v vseh prostorih.

Tehnični podatki

Poglej vse
Vse v enem 185L DHW tanku serije K 1 faza · R32
3 kW
Kit 3kW electric heater KIT-ADC03K3E5
Kit 6kW electric heater KIT-ADC03K6E5
Heating capacity (A +7°C, W 35°C) kW 3,20
COP (A +7°C, W 35°C) 5,33
Heating capacity (A +7°C, W 55°C) kW 3,20
COP (A +7°C, W 55°C) 2,81
Heating capacity (A +2°C, W 35°C) kW 3,20
COP (A +2°C, W 35°C) 3,64
Heating capacity (A +2°C, W 55°C) kW 3,20
COP (A +2°C, W 55°C) 2,19
Heating capacity (A -7°C, W 35°C) kW 3,30
COP (A -7°C, W 35°C) 2,80
Heating capacity (A -7°C, W 55°C) kW 3,20
COP (A -7°C, W 55°C) 1,79
Cooling capacity (A 35°C, W 7°C) kW 3,20
EER (A 35°C, W 7°C) 3,52
Cooling capacity (A 35°C, W 18°C) kW 3,20
EER (A 35°C, W 18°C) 4,71
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,07 / 3,47
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 200 / 136
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,20
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 165
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,00 / 2,83
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 157 / 110
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+
Indoor unit 3kW electric heater WH-ADC0309K3E5
Indoor unit 6kW electric heater WH-ADC0309K6E5
Indoor sound pressure (Heat) dB(A) 28
Indoor sound pressure (Cool) dB(A) 28
Indoor dimension (Height) mm 1.642
Indoor dimension (Width) mm 599
Indoor dimension (Depth) mm 602
Indoor net weight kg 100 (3kW) / 101 (6kW)
Water pipe connector Inch R 1-1/4
A class pump (Number of speeds) Variable Speed
A class pump (Input power Min) W 30
A class pump (Input power Max) W 120
Heating water flow (∆T=5 K. 35°C) L/min 9,2
Water volume L 185
Maximum water temperature °C 65
Material inside tank Stainless steel
Tapping profile according EN16147 L
DHW tank ERP average climate efficiency rating (2) A+ to F A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A++
DHW tank ERP cold climate efficiency rating (2) A+ to F A
DHW tank ERP average climate η ηwh % 128
DHW tank ERP average climate COPdHW COPdHW 3,20
DHW tank ERP warm climate η ηwh % 154
DHW tank ERP warm climate COPdHW COPdHW 3,86
DHW tank ERP cold climate η ηwh % 99
DHW tank ERP cold climate COPdHW COPdHW 2,48
Outdoor unit WH-UDZ03KE5
Outdoor sound power (Heat) (3) dB(A) 55
Outdoor dimension (Height) mm 622
Outdoor dimension (Width) mm 824
Outdoor dimension (Depth) mm 298
Outdoor net weight kg 37
Refrigerant (R32) / CO2 Eq. kg / T 0,9 / 0,608
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 25
Elevation difference (in/out) m 20
Pipe length for additional gas m 10
Additional gas amount g/m 20
Operation range - Outdoor ambient (Heat) °C -20 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43
Water outlet (Heat) °C 20 ~ 60
Water outlet (Cool) °C 5 ~ 20
Electrical information 3kW — 6kW
Electric backup heater (3kW — 6kW) kW 3,00 — 6,00
Recommended fuse A 16 / 16 — 16 / 30
Recommended minimum cable size, supply 1 (3kW — 6kW) (5) mm² 3 x 1,5 — 3 x 1,5
Recommended minimum cable size, supply 2 (3kW — 6kW) (5) mm² 3 x 1,5 — 3 x 4,0
(1) Lestvica od A+++ do D.
(2) Lestvica od A+ do F.
(3) Zvočna moč v skladu z z 811/2013, 813/2013 v EN12102-1:2017 pri +7 °C.
(4) Območje delovanja do –25 °C pri ogrevanju z razponom dolžine cevi od 3 ~ 40 m, območje delovanja do –15 °C pri ogrevanju z razponom dolžine cevi od 3 ~ 50 m.
(5) Preverite lokalne predpise.
* Izračun EER v COP je izdelan na podlagi EN14511.
** Ta izdelek je izdelan v skladu z Evropsko direktivo o kakovosti vode 98/83/ES, kot je bil je bila spremenjena z Direktivo 2015/1787/EU. ŽIVLJENJSKA DOBA IZDELKA NI ZAJAMČENA V PRIMERU UPORABE PODTALNICE, KOT JE IZVIRSKA VODA ALI VODA IZ VODNJAKE, UPORABA VODOVODNE VODE, V KATERI SO PRISOTNE SOLI ALI DRUGE NEČISTOČE, TER NA OBMOČJIH S KISLO VODO. V takih primerih tako stanejo stroški servisiranja v garancije v pristojnosti kupca.

Dopolnilni izdelki

Kaj je novega