Vse v enem 260-l DHW tanku K serije 1 faza - 3 faza · R32

9.00kW

KIT-ADC09K9E83 (WH-ADC0912K9E83 + WH-UDZ09KE8) / KIT-ADC09K9E8AN3 (WH-ADC0912K9E8AN3 + WH-UDZ09KE8)

Vse v enem 260-l DHW tanku K serije 1 faza - 3 faza · R32

Revolucija v oblikovanju, učinkovitosti, povezljivosti in trajnosti.
Aquarea Serija K je nizkoenergijski sistem za ogrevanje in hlajenje in proizvodnjo sanitarne tople vode, ki zagotavlja izjemno zmogljivost. Ta model je idealen za nove instalacije in dobro izolirane domove.
Izjemna učinkovitost in prihranek energije z minimalnim CO2 emisij in minimalnega prostora.
A premium bela, zvesta duhu Aquarea, ki ga poudarja brezhibno integriran krmilnik, ki zagotavlja eleganten črn pas čez celotno enoto. Model All in One ohranja svojo kompaktnost s svojim poseganje samo 598 x 600 mm, primerljivo z gospodinjskim aparatom.
1. zunanje enote z barvo Anthracite Grey, ki bo oblekla celotno paleto, ki je bila popolnoma prenovljena z inovativnim dizajnom To bo našlo svoje mesto v vseh prostorih.

  • COP do 4,90
  • A+++ pri ogrevanju pri 35 °C in A+ pri DHW
  • Vodna črpalka »A« s spremenljivo hitrostjo
  • Posoda DHW iz nerjavnega jekla z izolacijsko ploščo U-Vacua
  • DHW COP do 3,08
  • Vgrajeni magnetni vodni filter
  • Delovanje brez varnostnega ogrevanja pri -25 °C
  • 60 °C vroča voda tudi pri -10 °C zunanji temperaturi
  • Optimiziran uporabniški vmesnik in izboljšane funkcije
  • Izbirni adapter Wi-Fi

  • Tehnični podatki

    Poglej vse
    Vse v enem 260-l DHW tanku K serije 1 faza - 3 faza · R32
    9.00 kW
    Kit 3kW electric heater KIT-ADC09K9E83
    Heating capacity (A +7°C, W 35°C) kW 9,00
    COP (A +7°C, W 35°C) 4,90
    Heating capacity (A +7°C, W 55°C) kW 9,00
    COP (A +7°C, W 55°C) 2,97
    Heating capacity (A +2°C, W 35°C) kW 9,00
    COP (A +2°C, W 35°C) 3,63
    Heating capacity (A +2°C, W 55°C) kW 9,00
    COP (A +2°C, W 55°C) 2,26
    Heating capacity (A -7°C, W 35°C) kW 9,00
    COP (A -7°C, W 35°C) 2,88
    Heating capacity (A -7°C, W 55°C) kW 8,10
    COP (A -7°C, W 55°C) 2,07
    Cooling capacity (A 35°C, W 7°C) kW 8,80
    EER (A 35°C, W 7°C) 3,11
    Cooling capacity (A 35°C, W 18°C) kW 8,80
    EER (A 35°C, W 18°C) 4,63
    Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57
    Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 140
    Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
    Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34
    Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171
    Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
    Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26
    Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127
    Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
    Indoor unit 3kW electric heater WH-ADC0912K9E83
    Indoor sound pressure (Heat) dB(A) 33
    Indoor sound pressure (Cool) dB(A) 33
    Indoor dimension (Height) mm 2.036
    Indoor dimension (Width) mm 599
    Indoor dimension (Depth) mm 602
    Indoor net weight kg 119
    Water pipe connector Inch R 1¼
    A class pump (Number of speeds) Variable speed
    A class pump (Input power Min) W 145
    Heating water flow (∆T=5 K. 35°C) L/min 25,8
    Water volume L 260
    Maximum water temperature °C 65
    Material inside tank Stainless steel
    Tapping profile according EN16147 XL
    DHW tank ERP average climate efficiency rating (2) A+ to F A+
    DHW tank ERP warm climate efficiency rating (2) A+ to F A+
    DHW tank ERP cold climate efficiency rating (2) A+ to F A
    DHW tank ERP average climate η ηwh % 123
    DHW tank ERP average climate COPdHW COPdHW 3,08
    DHW tank ERP warm climate η ηwh % 134
    DHW tank ERP warm climate COPdHW COPdHW 3,35
    DHW tank ERP cold climate η ηwh % 94
    DHW tank ERP cold climate COPdHW COPdHW 2,35
    Outdoor unit WH-UDZ09KE8
    Outdoor sound power (Heat) (3) dB(A) 65
    Outdoor dimension (Height) mm 1.340
    Outdoor dimension (Width) mm 900
    Outdoor dimension (Depth) mm 320
    Outdoor net weight kg 90
    Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080
    Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
    Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
    Pipe length range m 3 ~ 30
    Elevation difference (in/out) m 20
    Pipe length for additional gas m 10
    Additional gas amount g/m 30
    Operation range - Outdoor ambient (Heat) °C -25 ~ +35
    Operation range - Outdoor ambient (Cool) °C +10 ~ +43
    Water outlet (Heat) °C 20 ~ 60
    Water outlet (Cool) °C 5 ~ 20
    Electrical information WH-ADC0912K9E83 / WH-ADC0912K9E8AN3
    Electric backup heater kW 9,00
    Recommended fuse A 20 / 20 (5)
    Recommended minimum cable size, supply 1 (5) mm² 5x1,5
    Recommended minimum cable size, supply 2 (5) mm² 5x1,5

    1) Lestvica od A+++ do D.
    2) Lestvica od A+ do F.
    3) Zvočna moč v skladu z 811/2013, 813/2013 in EN 12102-1:2017 pri +7 °C.
    4) Razpon delovanja do -25 °C pri ogrevanju z razponom dolžine cevi 3 ~ 40 m, razpon delovanja do -15 °C pri ogrevanju z razponom dolžine cevi 3 ~ 50 m.
    5) Preverite lokalne predpise.
    * Izračun EER in COP temelji v skladu z EN 14511.
    ** Ta izdelek je zasnovan v skladu z evropskim standardom za pitno vodo (EU) 2020/2184. Življenjska doba proizvoda ni zagotovljena v primeru uporabe podzemne vode, kot so izvirska voda ali vodnjak, uporaba vode iz pipe, ko so vsebovane soli ali druge nečistoče, niti na področjih kakovosti kisle vode. Stroški vzdrževanja in garancije, povezani s temi primeri, so odgovornost stranke.

    Kaj je novega