T-CAP Vse v enem 260-l DHW tank K Series 1 faza - 3 faza · R32
16.00kW
KIT-AXC16K9E83 (WH-ADC16K9E83 + WH-UXZ16KE8) / KIT-AXC16K9E8AN3 (WH-ADC16K9E8AN3 + WH-UXZ16KE8)
T-CAP Vse v enem 260-l DHW tanku K serije 1 faza - 3 faza · R32
Revolucija v oblikovanju, učinkovitosti, povezljivosti in trajnosti.Aquarea K Series je prelomni nizkoenergetski sistem za ogrevanje, hlajenje in proizvodnjo sanitarne tople vode, ki zagotavlja izjemno zmogljivost.Aquarea T-CAP je razpon za naknadno vgradnjo in nove gradnje, ki ohranja nazivno zmogljivost tudi pri izjemno hladnem okolju.
Zdaj je na voljo v večji različici All in One, kot nalašč za domove z visokim povpraševanjem po DHW. Kljub povečani zmogljivosti ohranja kompaktno površino le 599 x 602 mm, podobno kot pri standardni napravi.
Tehnični podatki
| T-CAP Vse v enem 260-l DHW tank K Series 1 faza - 3 faza · R32 | |||
|---|---|---|---|
| 16.00 kW | |||
| Kit 6kW electric heater | — | ||
| Heating capacity (A +7°C, W 35°C) | kW | 16,00 | |
| COP (A +7°C, W 35°C) | 4,38 | ||
| Heating capacity (A +7°C, W 55°C) | kW | 16,00 | |
| COP (A +7°C, W 55°C) | 2,72 | ||
| Heating capacity (A +2°C, W 35°C) | kW | 16,00 | |
| COP (A +2°C, W 35°C) | 3,10 | ||
| Heating capacity (A +2°C, W 55°C) | kW | 16,00 | |
| COP (A +2°C, W 55°C) | 2,07 | ||
| Heating capacity (A -7°C, W 35°C) | kW | 16,00 | |
| COP (A -7°C, W 35°C) | 2,39 | ||
| Heating capacity (A -7°C, W 55°C) | kW | 16,00 | |
| COP (A -7°C, W 55°C) | 1,71 | ||
| Cooling capacity (A 35°C, W 7°C) | kW | 13,40 | |
| EER (A 35°C, W 7°C) | 2,64 | ||
| Cooling capacity (A 35°C, W 18°C) | kW | 15,50 | |
| EER (A 35°C, W 18°C) | 3,60 | ||
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,46 / 3,31 | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 176 / 129) | |
| Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 5,88 / 4,09 | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 232 / 160) | |
| Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 3,83 / 3,20 | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 150 / 125) | |
| Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | |
| Indoor unit 6kW electric heater | — | ||
| Indoor sound pressure (Heat) | dB(A) | 33 | |
| Indoor sound pressure (Cool) | dB(A) | 33 | |
| Indoor dimension (Height) | mm | 2 036 | |
| Indoor dimension (Width) | mm | 599 | |
| Indoor dimension (Depth) | mm | 602 | |
| Indoor net weight | kg | 120 | |
| Water pipe connector | Inch | R1¼ | |
| A class pump (Number of speeds) | Variable speed | ||
| A class pump (Input power Max) | W | 145 | |
| Heating water flow (∆T=5 K. 35°C) | L/min | 45,9 | |
| Water volume | L | 260 | |
| Maximum water temperature | °C | 65 | |
| Material inside tank | Stainless steel | ||
| Tapping profile according EN16147 | XL | ||
| DHW tank ERP average climate efficiency rating (2) | A+ to F | A+ | |
| DHW tank ERP warm climate efficiency rating (2) | A+ to F | A+ | |
| DHW tank ERP cold climate efficiency rating (2) | A+ to F | A | |
| DHW tank ERP average climate η | ηwh % | 98 | |
| DHW tank ERP average climate COPdHW | COPdHW | 2,45 | |
| DHW tank ERP warm climate η | ηwh % | 123 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 3,08 | |
| DHW tank ERP cold climate η | ηwh % | 80 | |
| DHW tank ERP cold climate COPdHW | COPdHW | 2,00 | |
| Outdoor unit | WH-UXZ16KE8 | ||
| Outdoor sound power (Heat) (3) | dB(A) | 65 | |
| Outdoor dimension (Height) | mm | 1 340 | |
| Outdoor dimension (Width) | mm | 900 | |
| Outdoor dimension (Depth) | mm | 320 | |
| Outdoor net weight | kg | 103 | |
| Refrigerant (R290) / CO2 Eq. | kg / T | 1,83 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,235 | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
| Pipe length range | m | 3 ~ 30 | |
| Elevation difference (in/out) | m | 20 | |
| Pipe length for additional gas | m | 10 | |
| Additional gas amount | g/m | 30 | |
| Operation range - Outdoor ambient (Heat) | °C | -28 ~ +35 | |
| Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | |
| Water outlet (Heat) | °C | 20 ~ 60 | |
| Water outlet (Cool) | °C | 5 ~ 20 | |
| Electrical information | WH-ADC16K9E83 / WH-ADC16K9E8AN3 | ||
| Electric backup heater | kW | 9,00 | |
| Recommended fuse | A | 20 / 20 | |
| Recommended minimum cable size, supply 1 (5) | mm² | 5x2,5 | |
| Recommended minimum cable size, supply 2 (5) | mm² | 5x1,5 | |
1) Lestvica od A+++ do D.
2) Lestvica od A+ do F.
3) Zvočna moč v skladu z 811/2013, 813/2013 in EN 12102-1:2017 pri +7 °C.
4) Razpon delovanja do -25 °C pri ogrevanju z razponom dolžine cevi 3 ~ 40 m, razpon delovanja do -15 °C pri ogrevanju z razponom dolžine cevi 3 ~ 50 m.
5) Preverite lokalne predpise.
* Izračun EER in COP temelji v skladu z EN 14511.
** Ta izdelek je zasnovan v skladu z evropskim standardom za pitno vodo (EU) 2020/2184. Življenjska doba proizvoda ni zagotovljena v primeru uporabe podzemne vode, kot so izvirska voda ali vodnjak, uporaba vode iz pipe, kadar so vsebovane soli ali druge nečistoče, niti na področjih kakovosti kisle vode. Za stroške vzdrževanja in garancije, povezane s temi primeri, je odgovorna stranka.