Kombinacija 2 cevi ECOi EX serije MZ1 od 16 do 48 KM - R32

46HP

U-10MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8

Kombinacija 2 cevi ECOi EX MZ1 serije od 16 do 48 KM R32

Izjemna učinkovitost, kakovost, kompaktnost.


* Panasonicove interne raziskave. Model z močjo 12 KM z vgradnjo 30 m cevovoda.


Tehnični podatki

Poglej vse
Kombinacija 2 cevi ECOi EX serije MZ1 od 16 do 48 KM - R32
46 HP
Input power heating W 35,0,5
Current in cooling (1p 220V / 3p 380) A 68,0,40
Current in cooling (1p 230V / 3p 400) A 65,0,00
Current in cooling (1p 240V / 3p 415) A 62,0,80
Current in heating (1p 220V / 3p 380) A 59,0,60
Current in heating (1p 230V / 3p 400) A 56,0,60
Current in heating (1p 240V / 3p 415) A 54,0,70
Air flow m³/min 836
External static pressure Pa 80
Starting current A 1,0,00
Maximum allowable indoor / outdoor capacity ratio (4) % 50 ~ 130 (200)
Piping diameter (Liquid) (3) Inch (mm) 5/8 (15,88) / 3/4 (19,05)
Piping diameter (Balance) (3) Inch (mm) 04/01/2000
Piping diameter (Gas) (3) Inch (mm) 1-3/8 (34,96) / 15/8 (15,88)
Input power cooling kW 41,0,3
Sound power (Cool normal mode) dB(A) 86,0,5
Sound power (Heat normal mode) dB(A) 89,0,0
Sound pressure (Cool silent 1) dB(A) 66,0,5
Sound pressure (Cool silent 1) dB(A) 66,0,5
Sound pressure (Cool silent 2) dB(A) 64,0,5
Sound pressure (Cool silent 2) dB(A) 64,0,5
ηs,c 293,0,7
ηs,c 293,0,7
ηs,c 293,0,7
ηs,h 171,0,2
ηs,h 171,0,2
ηs,h 171,0,2
Net weight kg 821
SEER (2) 7,0,41
SCOP (2) 4,0,35
Operating range (Cool - Min) °C -10
Cooling capacity (Nominal) kW 128,0,0
Heating capacity (Nominal) kW 144,0,0
Refrigerant (R32) / CO2 Eq. kg / T 31,9 / 21,53
Outdoor unit U-10MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8
Operating range (Cool - Max) °C 52
Operating range (Heat - Min) °C -25
Operating range (Heat - Max) °C 24
COP (1) W/W 4,0,00
Dimension (Height) mm 1,660
Dimension (Width) mm 29/02/2420
Dimension (Depth) mm 765
Power supply (Voltage) V 11/06/2245
Power supply (Phase) Trifazni
Power supply (Frequency) Hz 50
EER (1) W/W 3,0,00

1) Izračun EER in COP temelji na standardu EN 14511.
2) SEER / SCOP se izračuna na podlagi sezonskih vrednosti "η" učinkovitosti hlajenja/ogrevanja prostora iz UREDBE KOMISIJE (EU) 2016/2281. SEER, SCOP = (η + popravek) × PEF.
3) Premer cevi pod 100 m za končno notranjo enoto / nad 100 m za končno notranjo enoto (če najdaljša ekvivalentna dolžina cevi presega 100 m, povečajte velikosti glavnih cevi za 1 rang za plinske in tekočinske cevi).
4) Če so izpolnjeni naslednji pogoji, je učinkovito območje nad 130 % in pod 200 %: A. Upoštevajte omejeno število priključljivih notranjih enot. B. Spodnja meja območja delovanja za zunanjo temperaturo ogrevanja je omejena na -10 °C WB (standardno -25 °C WB). C. Hkratno delovanje je omejeno na manj kot 130 % priključenih notranjih enot.

Kaj je novega