UFE Mini-Standtruhen | R32
5.0kW
KIT-Z50-CFE (CS-Z50CFEAW + CU-Z50CBEA)
Mini-Standtruhen – Energieeffizienz, Komfort, gesunde Raumluft und flexible Einbaumöglichkeiten
Die Mini-Standtruhen sind mit dem nanoe™ X-System ausgestattet. Höchste Energieeffizienz (A++), größter Komfort (Flüsterbetrieb ab 20 dB(A)) und gesunde Raumluft gepaart mit einem neuen, zukunftsweisenden Design.
Technische Daten
| UFE Mini-Standtruhen | R32 | |||
|---|---|---|---|
| 5.0 kW | |||
| Kit | KIT-Z50-CFE | ||
| Cooling capacity (Nominal) | kW | 5,00 | |
| Cooling capacity (Min) | kW | 0,90 | |
| Cooling capacity (Max) | kW | 5,70 | |
| EER (Nominal) (1) | W/W | 3,60 | |
| EER (Min) (1) | W/W | 3,53 | |
| EER (Max) (1) | W/W | 3,15 | |
| SEER (2) | 6,70 A++ | ||
| Pdesign (cooling) | kW | 5,00 | |
| Input power cooling (Nominal) | kW | 1,39 | |
| Input power cooling (Min) | kW | 0,26 | |
| Input power cooling (Max) | kW | 1,81 | |
| Annual energy consumption cooling (3) | kWh/a | 261 | |
| Heating capacity (Nominal) | kW | 5,80 | |
| Heating capacity (Min) | kW | 0,90 | |
| Heating capacity (Max) | kW | 8,10 | |
| Heating capacity at -7°C | kW | 5,03 | |
| COP (Nominal) (1) | W/W | 3,74 | |
| COP (Min) (1) | W/W | 3,46 | |
| COP (Max) (1) | W/W | 3,12 | |
| SCOP (2) | 4,30 A+ | ||
| Pdesign at -10°C | kW | 4,40 | |
| Input power heating (Nominal) | kW | 1,55 | |
| Input power heating (Min) | kW | 0,26 | |
| Input power heating (Max) | kW | 2,60 | |
| Annual energy consumption heating (3) | kWh/a | 1.433 | |
| Indoor unit | CS-Z50CFEAW | ||
| Indoor air flow (Cool) | m³/min | 11,9 | |
| Indoor air flow (Heat) | m³/min | 13,4 | |
| Moisture removal volume | L/h | 2,8 | |
| Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | |
| Indoor sound pressure (Cool -Lo) (4) | dB(A) | 31 | |
| Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 27 | |
| Indoor sound pressure (Heat -Hi) (4) | dB(A) | 46 | |
| Indoor sound pressure (Heat -Lo) (4) | dB(A) | 33 | |
| Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 29 | |
| Indoor dimension (Height) | mm | 600 | |
| Indoor dimension (Width) | mm | 750 | |
| Indoor dimension (Depth) | mm | 207 | |
| Indoor net weight | kg | 13 | |
| nanoe X Generator | Markierung 3 | ||
| Outdoor unit | CU-Z50CBEA | ||
| Outdoor power source | V | 230 | |
| Outdoor recommended fuse | A | 16 | |
| Outdoor connection indoor / outdoor | mm² | 4x1,5 | |
| Outdoor air flow (Cool) | m³/min | 39,7 | |
| Outdoor air flow (Heat) | m³/min | 36,4 | |
| Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
| Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 48 | |
| Outdoor dimension (Height) (5) | mm | 695 | |
| Outdoor dimension (Width) (5) | mm | 875 | |
| Outdoor dimension (Depth) (5) | mm | 320 | |
| Outdoor net weight | kg | 43 | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
| Pipe length range | m | 3 ~ 30 | |
| Elevation difference (in/out) (6) | m | 20 | |
| Pipe length for additional gas | m | 7,5 | |
| Additional gas amount | g/m | 15 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,13 / 0,76 | |
| Operating range (Cool - Min) | °C | -10 | |
| Operating range (Cool - Max) | °C | +43 | |
| Operating range (Heat - Min) | °C | -15 | |
| Operating range (Heat - Max) | °C | +24 | |
1) EER-/COP-Werte werden in Übereinstimmung mit EN14511 berechnet.
2) Energieeffizienzklassenskala von A+++ bis D.
3) Der Jahresstromverbrauch errechnet sich nach den Vorgaben der EU-Verordnung 626/2011.
4) Messpositionen – Innengerät: 1 m Entfernung vor dem Gerät in 1 m Höhe. Die Schalldruckpegel-Messwerte basieren auf JIS C 9612. Flüster: Flüsterbetrieb. Niedrig: niedrigste einstellbare Ventilatordrehzahl.
5) Für den Leitungsanschluss sind in der Breite 70 mm hinzuzuaddieren.
6) Außengerät höher angeordnet als das Innengerät.