K Generation 1 phase · R32
12kW
KIT-WC12K6E5 (WH-SDC12K6E5 + WH-UDZ12KE5)
Aquarea High Performance Bi-bloc K Generation Single phase
A revolution in design, efficiency, connectivity and sustainability.Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.
- COP up to 5,33
- A+++ in heating at 35°C and A+ in DHW
- “A” water pump with variable speed
- Long piping lengths
- Built-in magnetic water filter
- Operation without backup heating at -25°C
- 60°C hot water even at -10°C outside temperature
- Optimised user interface and improved features
- Optional Aquarea Smart and Service Cloud and integration into BMS projects
Further comfort and peace of mind with Aquarea
Specifications
| K Generation 1 phase · R32 | |||
|---|---|---|---|
| 12 kW | |||
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 256 / 171 | |
| Elevation difference (in/out) | m | 20 | |
| Outdoor dimension (Depth) | mm | 320 | |
| Outdoor dimension (Width) | mm | 900 | |
| Heating water flow (∆T=5 K. 35°C) | L/min | 34,4 | |
| A class pump (Number of speeds) | Variable speed | ||
| Water pipe connector | Inch | R 1¼ | |
| Indoor sound pressure (Cool) | dB(A) | 33 | |
| Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | |
| Operation range - Outdoor ambient (Heat) | °C | -25 ~ +35 | |
| Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 169 / 127 | |
| Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,58 / 3,33 | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 180 / 130 | |
| EER (A 35°C, W 18°C) | 3,92 | ||
| Cooling capacity (A 35°C, W 18°C) | kW | 10,70 | |
| Electric backup heater | kW | 6,00 | |
| Outdoor sound power (Heat) (2) | dB(A) | 65 | |
| Recommended fuse | A | 30 / 30 | |
| Recommended minimum cable size, supply 2 (5) | mm² | 3x4,0 | |
| Recommended minimum cable size, supply 1 (5) | mm² | 3x4,0 | |
| COP (A -7°C, W 55°C) | 1,97 | ||
| Electrical information | 6kW | ||
| Indoor unit 6kW electric heater | WH-SDC12K6E5 | ||
| Indoor unit 3kW electric heater | — | ||
| Kit 6kW electric heater | KIT-WC12K6E5 | ||
| Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | |
| COP (A +7°C, W 35°C) | 4,78 | ||
| Indoor net weight | kg | 41 | |
| Indoor dimension (Height) | mm | 892 | |
| Pipe length range | m | 3 ~ 30 | |
| EER (A 35°C, W 7°C) | 2,68 | ||
| Cooling capacity (A 35°C, W 7°C) | kW | 10,70 | |
| COP (A -7°C, W 35°C) | 2,74 | ||
| Heating capacity (A -7°C, W 35°C) | kW | 10,10 | |
| COP (A +2°C, W 35°C) | 3,44 | ||
| Heating capacity (A +2°C, W 35°C) | kW | 11,50 | |
| Outdoor dimension (Height) | mm | 1.340 | |
| Heating capacity (A +7°C, W 35°C) | kW | 12,10 | |
| Additional gas amount | g/m | 30 | |
| Heating capacity (A -7°C, W 55°C) | kW | 8,40 | |
| COP (A +2°C, W 55°C) | 2,25 | ||
| Heating capacity (A +2°C, W 55°C) | kW | 9,20 | |
| COP (A +7°C, W 55°C) | 2,96 | ||
| Heating capacity (A +7°C, W 55°C) | kW | 12,00 | |
| Outdoor unit | WH-UDZ12KE5 | ||
| Pipe length for additional gas | m | 10 | |
| Pipe diameter (Gas) | Inch (mm) | 1/2 (12,7) | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Indoor dimension (Depth) | mm | 348 | |
| Indoor dimension (Width) | mm | 500 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,6 / 1,080 | |
| Indoor sound pressure (Heat) | dB(A) | 33 | |
| Outdoor net weight | kg | 88 | |
2) Sound power level in accordance to EN12102 under conditions of the EN14825.
3) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
4) Between outdoor ambient -10°C and -15°C, the water outlet temperature gradually decreases from 60°C to 55°C.
5) Check local regulations.
** EER and COP calculation is based in accordance to EN14511.
*** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.