U2 type 4 way 90x90 cassette · R32/R410A

Previous capacity Next capacity

2.2kW

S-22MU2E5C

U2 type 4 way 90x90 cassette · R32/R410A

Trusted power, high efficiency, and comfort. Econavi intelligent sensors optimise heating and cooling to save energy.

nanoe™ X is built-in as standard for improved indoor air quality.


  • High performance turbo fan
  • A modern flat panel design to blend into any space
  • Graphite black and white panels providing options to suit a variety of commercial applications
  • Light weight, easy piping
  • Lower noise in slow fan operation
  • Econavi: Floor temperature and humidity sensor added. Activity amount detection and new circulator
  • nanoe™ X (Generator Mark 3: 48 trillion hydroxyl radicals/sec) as standard for better indoor air quality
  • Indoor unit internal cleaning with nanoe™ X
  • Ceiling height up to 5,0m
  • Powerful drain pump gives 850mm lift
  • High volume fresh air input with optional air-intake plenum and chamber (CZ-FDU3+CZ-ATU2)

  • Graphite black or white panels to suit various commercial applications

    Specifications

    See all
    U2 type 4 way 90x90 cassette · R32/R410A
    2.2 kW
    Indoor unit S-22MU2E5C
    Cooling capacity (Nominal) kW 2,2
    Input power cooling kW 20,00
    Current cooling A 0,21
    Heating capacity (Nominal) kW 2,5
    Input power heating W 20,00
    Current heating A 0,20
    Fan type Turbo fan
    nanoe X Generator Mark 3
    Air flow (Hi) m³/min 12,8
    Air flow (Med) m³/min 12,1
    Air flow (Lo) m³/min 11,5
    Cooling capacity (Nominal) kW 2,2
    Sound pressure (Hi) dB(A) 30
    Sound pressure (Med) dB(A) 29
    Sound pressure (Lo) dB(A) 28
    Sound power (Med) dB(A) 45
    Sound power (Hi) dB(A) 44
    Sound power (Lo) dB(A) 43
    Indoor dimension (Height) mm 256
    Indoor dimension (Width) mm 840
    Indoor dimension (Depth) mm 840
    Panel dimension (Height) mm 33,5
    Panel dimension (Depth) mm 950
    Indoor net weight kg 20
    Panel net weight kg 5
    Piping diameter R32 model (Liquid) Inch (mm) 1/4 (6,35)
    Piping diameter R32 model (Gas) Inch (mm) 1/2 (12,70)
    Piping diameter R410A model (Liquid) Inch (mm) 1/4 (6,35)
    Piping diameter R410A model (Gas) Inch (mm) 1/2 (12,70)

    (1) When the piping diameter is (liquid) Ø1/4 (6,35) - (gas) Ø1/2 (12,70), connect the liquid socket tube (Ø1/4 (6,35) - Ø3/8 (9,52)) to the liquid tubing side indoor unit and connect the gas socket tube (Ø1/2 (12,70) - Ø5/8 (15,88)) to the gas tubing side indoor unit.