2-Pipe ECOi EX MZ1 Series combination from 16 to 48HP - R32

24HP

U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8

2-Pipe ECOi EX MZ1 Series combination from 16 to 48HP R32

Extreme efficiency, quality, compact.


* Panasonic’s internal research. 12HP model with 30m piping installation.


Specifications

See all
2-Pipe ECOi EX MZ1 Series combination from 16 to 48HP - R32
24 HP
Input power heating W 16,0,7
Current in cooling (1p 220V / 3p 380) A 35,0,10
Current in cooling (1p 230V / 3p 400) A 33,0,30
Current in cooling (1p 240V / 3p 415) A 32,0,10
Current in heating (1p 220V / 3p 380) A 29,0,43
Current in heating (1p 230V / 3p 400) A 27,0,96
Current in heating (1p 240V / 3p 415) A 26,0,94
Air flow m³/min 627
External static pressure Pa 80
Starting current A 1,0,00
Maximum allowable indoor / outdoor capacity ratio (4) % 50 ~ 130 (200)
Piping diameter (Liquid) (3) Inch (mm) 1/2 (12,70) / 5/8 (15,88)
Piping diameter (Balance) (3) Inch (mm) 04/01/2000
Piping diameter (Gas) (3) Inch (mm) 1-1/8 (28,58) / 1-3/8 (34,96)
Input power cooling kW 20,0,4
Sound power (Cool normal mode) dB(A) 80,0,0
Sound power (Heat normal mode) dB(A) 80,0,0
Sound pressure (Cool silent 1) dB(A) 59,0,0
Sound pressure (Cool silent 1) dB(A) 59,0,0
Sound pressure (Cool silent 2) dB(A) 57,0,0
Sound pressure (Cool silent 2) dB(A) 57,0,0
ηs,c 286,0,8
ηs,c 286,0,8
ηs,c 286,0,8
ηs,h 169,0,8
ηs,h 169,0,8
ηs,h 169,0,8
Net weight kg 609
SEER (2) 7,0,24
SCOP (2) 4,0,32
Operating range (Cool - Min) °C -10
Cooling capacity (Nominal) kW 67,0,2
Heating capacity (Nominal) kW 75,0,0
Refrigerant (R32) / CO2 Eq. kg / T 18,9 / 12,76
Outdoor unit U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8
Operating range (Cool - Max) °C 52
Operating range (Heat - Min) °C -25
Operating range (Heat - Max) °C 24
COP (1) W/W 4,0,40
Dimension (Height) mm 1,660
Dimension (Width) mm 31/01/2540
Dimension (Depth) mm 765
Power supply (Voltage) V 11/06/2245
Power supply (Phase) Three phase
Power supply (Frequency) Hz 50
EER (1) W/W 3,0,20

1) EER and COP calculation is based in accordance to EN 14511.
2) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.
3) Piping diameter under 100m for ultimate indoor unit / over 100m for ultimate indoor unit (if the longest piping equivalent length exceeds 100m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
4) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.