Hydraulic Split All in One 120l DHW tank L Series 1 phase · R290

Aquarea High Performance Hydraulic Split All in One 120l DHW tank L Series

A revolution in design, efficiency, connectivity and sustainability. Aquarea L Series is engineered with R290 natural refrigerant (GWP 0,02). It is the ideal for renovations, where a high water outlet temperature is required or homes looking for a high-performance heat pump, to maximise energy savings and minimise CO2 emissions.


Now available in a more compact All in One version, perfect for homes with lower DHW demand, it maintains a footprint of just 599 x 602 mm—similar to a standard appliance.

Further comfort and peace of mind with Aquarea

Specifications

See all
Hydraulic Split All in One 120l DHW tank L Series 1 phase · R290 SINGLE PHASE
5.00 kW 7.00 kW 9.00 kW
Water volume L 30 30 30
Outdoor dimension (Depth) mm 430 430 430
Outdoor dimension (Width) mm 980 980 980
DHW tank ERP cold climate η ηwh % 90 90 90
DHW tank ERP warm climate η ηwh % 134 134 134
DHW tank ERP average climate η ηwh % 115 115 115
Tapping profile according EN16147 M M M
Material inside tank Stainless steel Stainless steel Stainless steel
Maximum water temperature °C 65 65 65
Elevation difference (in/out) m 10 10 10
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++/A++ A++/A++ A++/A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,25/3,28 4,25/3,29 4,31/3,33
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 167/128 167/129 170/130
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++/A+++ A+++/A+++ A+++/A+++
Outdoor sound power (Heat) (2) dB(A) 52 53 54
Pipe length range maximum m 30 30 30
Pipe length range standard m 5 5 5
Water pipe connector (outdoor units) Inch 1 1 1
Water pipe connector (indoor units) Inch 1 1 1
Water pipe connector (shower) Inch ¾ ¾ ¾
Water pipe connector (room) Inch
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,00/4,27 6,31/4,52 6,44/4,50
Indoor unit 3kW electric heater WH-ADC0509L3E51 WH-ADC0509L3E51 WH-ADC0509L3E51
DHW tank ERP cold climate COPdHW COPdHW 2,26 2,26 2,26
DHW tank ERP warm climate COPdHW COPdHW 3,35 3,35 3,35
DHW tank ERP average climate COPdHW COPdHW 2,88 2,88 2,88
Operation range - outdoor temperature (Cool) °C +10~+43 +10~+43 +10~+43
Operation range - outdoor temperature (Heat) °C -25~+35 -25~+35 -25~+35
Water outlet (Cool) °C 5~20 5~20 5~20
Water outlet (Heat) °C 20~75 20~75 20~75
COP (A +7°C, W 35°C) 5,05 4,93 4,55
Indoor net weight kg 79 79 79
Indoor dimension (Height) mm 1.293 1.293 1.293
EER (A 35°C, W 7°C) 3,23 3,03 2,82
Cooling capacity (A 35°C, W 7°C) kW 5,00 7,00 8,20
COP (A -7°C, W 35°C) 3,01 3,01 2,80
Heating capacity (A -7°C, W 35°C) kW 5,00 5,80 7,00
COP (A +2°C, W 35°C) 3,52 3,43 3,41
Heating capacity (A +2°C, W 35°C) kW 5,00 6,85 7,00
Outdoor dimension (Height) mm 996 996 996
Heating capacity (A +7°C, W 35°C) kW 5,00 7,00 9,00
COP (A +2°C, W 55°C) 2,34 2,34 2,41
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 237/168 249/178 255/177
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++/A++ A+++/A++ A+++/A++
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,06/3,63 4,96/3,62 4,84/3,67
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 200/142 195/142 190/144
EER (A 35°C, W 18°C) 5,00 4,73 4,19
Cooling capacity (A 35°C, W 18°C) kW 5,00 7,00 9,00
COP (A -7°C, W 55°C) 2,12 2,12 2,13
Heating capacity (A -7°C, W 55°C) kW 5,00 5,80 7,00
Heating capacity (A +2°C, W 55°C) kW 5,00 6,25 7,00
COP (A +7°C, W 55°C) 3,07 2,98 3,03
Heating capacity (A +7°C, W 55°C) kW 5,00 7,00 8,90
Outdoor unit WH-WDG05LE5 WH-WDG07LE5 WH-WDG09LE5
Indoor dimension (Depth) mm 602 602 602
Indoor dimension (Width) mm 599 599 599
Outdoor net weight kg 98 98 97

1) Scale from A+++ to D.

2) Scale from A+ to F. 

3) Sound power level in accordance to EN 12102 under conditions of the EN14825 (part load).

4) Check local regulations

* EER and COP calculation is based in accordance to EN 14511.