More hydroxyl radicals, greater benefits

nanoe™ X technology has evolved dramatically. Compared to the first nanoe™ generator developed by Panasonic in 2003, the nanoe X Generator Mark 2, developed in 2019, generates 20 times and the nanoe X Generator Mark 3, developed in 2021, even generates 100 times as many hydroyl radicals.


The decisive factor for the cleaning effects is hydroxyl radical amount, which contained in nanoe™ X particles.

nanoe™

(original)


Hydroxyl radicals/sec

480 billion


nanoe X

Generator Mark 1


Hydroxyl radicals/sec

4.8 trillion


nanoe X

Generator Mark 2


Hydroxyl radicals/sec

9.6 trillion


nanoe X

Generator Mark 3


Hydroxyl radicals/sec

48 trillion


Higher concentration, even in large spaces

Greater effectiveness even in large spaces of more than 100 m².


Simulation with nanoe X Generator Mark 3 in a room size of 112 m²

nanoe™ X diffuse into the space in a short time to quickly reach the effective concentration level.

Conditions of the simulation: Inspection / modell: 4 way cassette / room size: 112 m² / room height: 2,4 m / Position of IDU: centre of space / ventilation: 3 times/hour.

2 minutes later


5 minutes later


10 minutes later


Evolution of the nanoe™ X Effect

Effectiveness in large space with Generator Mark 3.

Inhibits virus.


An air conditioner equipped with nanoe X Generator Mark 3 inhibits activity of adhered virus (Bacteriophage) by 98,81% in 4 hours.


a. Test ambient / b. Test result (bacteriophage) / c. Survival rate (%) / d. Natural reduction


Testing organisation: SGS Inc / Test subject: Adhered Bacteriophage / Test volume: Approx. 139m large space (6,6×8,9x2.48m)

Test result: Inhibited 98,81% in 4 hours

Test repot no.: SHES210901902583



Deodorise 1) 2).


An air conditioner equipped with nanoe™ X Generator Mark 3 reduces cigarette smoke odour intensity by 1,7 levels in 30 mins.


a. Test ambient / b. Test result (Cigarette smoke odour) / c. Odour intensity (6-Level odour intensity: 0: Odourless, 1: Hardly noticeable, 2: Minimally identifiable, 3: Immediately noticeable, 4: Strong, 5: Intensely disagreeable) / d. Natural reduction


Testing organisation: SGS Inc / Test subject: Adhered cigarette smoke odour / Test volume: Approx. 139m large space (6,6×8,9x2.48m)

Test result: Odour intensity reduced 1,7 levels in 30 mins.

Test repot no.: SHES210901902478


Better deodorisation results than with the

Generator Mark 2.


Sweet odour 3).


a. Odour intensity (0: Odourless, 1: Hardly noticeable, 2: Minimally identifiable, 3: Immediately noticeable, 4: Strong, 5: Intensely disagreeable)



Greatly improved deodorisation speed with the Generator Mark 3.


Urine odour 4) / Faeces odour 5)


a. Odour intensity (0: Odourless, 1: Hardly noticeable, 2: Minimally identifiable, 3: Immediately noticeable, 4: Strong, 5: Intensely disagreeable) / b. Natural reduction


Inhibits pollen.


The result of nanoe™ X Generator Mark 3

Inhibits pollen in 1/4 the time of nanoe™ X Generator Mark 2 7)


a. Comparison of time required to inhibit 99% of cedar pollen 8) / b. Hours



Inhibits mould.


Inhibits mould growth in fans and heat exchangers 6) - Internal Cleaning Function - After cooling/drying function, the inside of the indoor unit is automatically dried.


a. Dried with a fan to dissipate internal heat

nanoe™ X Operating time: Operation ON: Air purification with nanoe™ X - Operation OFF: Internal Cleaning function

b. Internal circulation of nanoe™ X with a fan

nanoe™ X Operating time: Operating timing ON: Cooling/Heating/Dry/Fan - Operating timing OFF: Cool/Dry operation



1) This is not a proven effect in an actual operating space. The deodorizing effect depends on the size of the operating space, ambient environment (temperature and humidity), operation time, and types of odours absorbed in fibres.

2) Effectiveness in a test space of approx. 230m3. The figures are not the results of tests conducted in an actual operating space.

3) [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230m3) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe™ X Generator Mark 3 and release of nanoe™ [Target] Adhered sweat odour (hexanoic acid) [Test result] Odour intensity was reduced to 1,0 in 2 hours (R21HM004-0) [Method of deodorisation] Operation of a CS-P80U6 4-way cassette equipped with a nanoe™ X Generator Mark 2 and release of nanoe™ [Target] Adhered sweat odour (hexanoic acid) [Test Result] Odour intensity was reduced to 3,1 in 2 hours (L19YK032-11)

4) [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230m3) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe™ X Generator Mark 3 and release of nanoe™ [Target] Adhered urine odour (trimethylamine) [Test Result] Odour intensity reduced to 1,0 in 2 hours (R21HM005-0)

5) [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230m3) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe™ X Generator Mark 3 and release of nanoe™ [Target] Adhered faeces odour (methyl mercaptan) [Test Result] Odour intensity reduced to 1,0 in 2 hours (R21HM006-0)

6) While this function is effective in inhibiting mould growth, it does not prevent mould from occurring. The mould growth inhibition effect may vary depending on the installation environment and operating time. *When using the nanoe™ X Generator Mark 3 function, a multi-function wired remote control (CZ-10RT4C) is required. (The floor-standing type with a built-in control switch in the main unit can be used.) *Only ON/OFF operation is possible with the multilingual wired remote controller (CZ-10RTF4). Also, local setup is required to use the nanoe™ X Generator Mark 3.

7) Effect after 3 hours in a test space of approx. 24m3. The figures are not the results of testing in an actual operating space.

8) <nanoe™ X Generator Mark 1> [Testing organisation] Panasonic Product Analysis Center [Test method] ELISA method of measuring allergens adhering to fabric in a test room (approx. 24m3) [Method of inhibition] Release of nanoe™ [Target] Adhered allergen (cedar pollen) [Test Result] Inhibition of 99% or more in 24 hours (4AA33-151001-F01) <nanoe™ X Generator Mark 2>

[Testing organisation] Panasonic Product Analysis Center, [Test method] ELISA method of measuring allergens adhering to fabric in a test room (approx. 24m3) [Method of inhibition] Release of nanoe™ [Target] Adhered allergen (cedar pollen) [Test Result] Inhibition of 99% or more in 12 hours confirmed (L19YA009) <nanoe™ X Generator Mark 3> [Testing organisation] Panasonic Product Analysis Center [Test method] ELISA method of measuring allergens adhering to fabric in a test room (approx. 24m3) [Method of inhibition] Release of nanoe™ [Target] Adhered allergen (cedar pollen) [Test Result] Inhibition of 99% or more in 3 hours (H21YA017-1)