Free Multi System Z · R32
4.1kW
CU-2Z41CBE
Free Multi System Z · R32
Full flexibility up to 9,0kW and up to 5 ports with wide range of indoor units including high performance Etherea indoor units, reaching up to A+++ or A++ energy class.
- Built-in wifi and compatible with voice control in all wall indoors (optional in other types)
- Wide choice of indoor units to adapt to each room
- Wall type Etherea and Floor console with nanoe™ X, technology with the benefits of hydroxyl radicals, improve protection 24/7
- Compact wall type TZ with PM2.5 Filter
- Other indoors: Cassette 60:60 and Duct type units
- Stylish and premium design
- Flexible installation, compact units and large connection distance
Free Multi indoor unit options for every room
Specifications
| Free Multi System Z · R32 | |||
|---|---|---|---|
| 4.1 kW | |||
| Outdoor unit | CU-2Z41CBE | ||
| Indoor nominal capacity (Min ~ Max) | kW | 3,2 ~ 6,0 kW | |
| Cooling capacity (Nominal) | kW | 4,10 | |
| Cooling capacity (Min) | kW | 1,50 | |
| Cooling capacity (Max) | kW | 5,20 | |
| EER (Nominal) (1) | W/W | 4,36 | |
| EER (Min) (1) | W/W | 6,00 | |
| EER (Max) (1) | W/W | 3,80 | |
| SEER (2) | 9,10 A+++ | ||
| Pdesign (cooling) | kW | 4,10 | |
| Input power cooling (Nominal) | kW | 0,94 | |
| Input power cooling (Min) | kW | 0,25 | |
| Input power cooling (Max) | kW | 1,37 | |
| Annual energy consumption cooling (3) | kWh/a | 158 | |
| Heating capacity (Nominal) | kW | 4,60 | |
| Heating capacity (Min) | kW | 1,10 | |
| Heating capacity (Max) | kW | 7,00 | |
| Heating capacity at -7°C | kW | 4,18 | |
| COP (Nominal) (1) | W/W | 4,95 | |
| COP (Min) (1) | W/W | 5,24 | |
| COP (Max) (1) | W/W | 3,91 | |
| SCOP (2) | 4,80 A++ | ||
| Pdesign at -10°C | kW | 3,50 | |
| Input power heating (Nominal) | kW | 0,93 | |
| Input power heating (Min) | kW | 0,21 | |
| Input power heating (Max) | kW | 1,79 | |
| Annual energy consumption heating (3) | kWh/a | 1 021 | |
| Power supply (Voltage) | V | 230 | |
| Current cooling | A | 4,30 | |
| Current heating | A | 4,30 | |
| Outdoor recommended fuse | A | 16 | |
| Recommended power cable section | mm² | 2,5 | |
| Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
| Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 50 | |
| Outdoor dimension (Height) (5) | mm | 619 | |
| Outdoor dimension (Width) (5) | mm | 824 | |
| Outdoor dimension (Depth) (5) | mm | 299 | |
| Outdoor net weight | kg | 37 | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | |
| Pipe length range total (6) | m | 6 ~ 30 | |
| Pipe length range to one unit | m | 3 ~ 20 | |
| Elevation difference (in/out) | m | 10 | |
| Pipe length for additional gas | m | 20 | |
| Additional gas amount | g/m | 15 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,18 / 0,797 | |
| Operating range (Cool - Min) | °C | -10 | |
| Operating range (Cool - Max) | °C | +46 | |
| Operating range (Heat - Min) | °C | -15 | |
| Operating range (Heat - Max) | °C | +24 | |
1) EER and COP calculation is based in accordance to EN14511.
2) Energy Label Scale from A+++ to D.
3) The annual energy consumption is calculated in accordance to EU/626/2011.
4) The sound pressure of the units shows the value measured of a position 1 m in front and 1 m in rear side of the main body. The sound pressure is measured in accordance with JISC9612.
5) Add 70 or 95 mm for piping port.
6) Minimum piping length is 3 meters per indoor unit.