PACi NX Series Standard multi zone duct unit

14.0kW

KIT-140PQ51Z5 (S-1014PQ51E + U-140PZ3E5)

Multi zone duct unit – PQ4 / PQ5

Zoned air flow. Maximum comfort. Minimal energy.

Specifications

See all
PACi NX Series Standard multi zone duct unit
14.0 kW
Kit KIT-140PQ51Z5
Remote controller PCZ‑EEB749
Cooling capacity (Nominal) kW 13.2
Cooling capacity (Min) kW 3. 4
Cooling capacity (Max) kW 14.8
Heating capacity (Nominal) kW 13.3
Heating capacity (Min) kW 3.5
Heating capacity (Max) kW 15.9
SCOP/ηsc (2) % 141.4%
Indoor unit S-1014PQ51E
Number of fans 5
Air flow (Hi) m³/min 2250
Air flow (Med) m³/min 1800
Air flow (Lo) m³/min 1450
Indoor dimension (Height) mm 266
Indoor dimension (Width) mm 1455
Indoor dimension (Depth) mm 701
Indoor net weight kg 57
Outdoor unit U-140PZ3E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 20.50
Current in cooling (1p 230V / 3p 400) A 19.60
Current in cooling (1p 240V / 3p 415) A 18.8
Current in heating (1p 220V / 3p 380) A 17.20
Current in heating (1p 230V / 3p 400) A 16.40
Current in heating (1p 240V / 3p 415) A 15.80
Outdoor air flow (Cool) m³/min 84.0
Outdoor air flow (Heat) m³/min 82.0
Outdoor sound pressure (Cool -Hi) dB(A) 56
Outdoor sound pressure (Heat -Hi) dB(A) 56
Outdoor sound power (Cool -Hi) dB(A) 74
Outdoor sound power (Heat -Hi) dB(A) 74
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 87
Pipe length range m 5 ~ 50
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2.80 / 1.89
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C 43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C 24

1) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN14825. 

2) Medium external static pressure setting from factory. 

3) Outdoor unit located lower / outdoor unit located higher. 

*Recommended fuse for the indoor 3A.

Complementary products