5.00kW

KIT-BZ50-XKE (CS-BZ50XKE + CU-BZ50XKE)

Wall-mounted BZ super-compact Inverter

BZ is a compact and quiet wall split series with PM2.5 Filter and high standards specs.

Why install a Panasonic Air Conditioning unit?

Manage your Panasonic solutions anytime, anywhere

Specifications

See all
BZ super-compact · R32
5.00 kW
Cooling capacity (Min) kW 0,98
Input power heating (Min) kW 0,21
COP (Max) (1) W/W 3,06
COP (Min) (1) W/W 4,67
Heating capacity (Max) kW 7,50
Heating capacity (Min) kW 0,98
Input power cooling (Max) kW 1,86
Input power cooling (Min) kW 0,25
EER (Max) (1) W/W 2,90
EER (Min) (1) W/W 3,92
Cooling capacity (Max) kW 5,40
Input power heating (Max) kW 2,45
Operating range (Heat - Max) °C +24
Operating range (Heat - Min) °C -15
Operating range (Cool - Max) °C +43
Elevation difference (in/out) (6) m 15
Outdoor dimension (Depth) (5) mm 299
Outdoor dimension (Width) (5) mm 824
Outdoor dimension (Height) (5) mm 619
Outdoor sound pressure (Heat -Hi) (4) dB(A) 49
Outdoor unit CU-BZ50XKE
Outdoor air flow (Heat) m³/min 32,7
Outdoor air flow (Cool) m³/min 32,7
Indoor unit CS-BZ50XKE
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 34
Indoor sound pressure (Heat -Lo) (4) dB(A) 37
Indoor sound pressure (Heat -Hi) (4) dB(A) 44
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 34
Indoor sound pressure (Cool -Lo) (4) dB(A) 37
Moisture removal volume L/h 2,8
Indoor air flow (Heat) m³/min 13,2
Indoor air flow (Cool) m³/min 12,5
Indoor connection indoor / outdoor mm² 4 x 2,5
Indoor power source V 230
Annual energy consumption heating (3) kWh/a 1.366
Annual energy consumption cooling (3) kWh/a 269
Input power cooling (Nominal) kW 1,65
Pdesign (cooling) kW 5,00
SEER (2) 6,50 A++
Outdoor net weight kg 36
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Indoor net weight kg 8
Indoor dimension (Height) mm 290
Indoor sound pressure (Cool -Hi) (4) dB(A) 44
SCOP (2) 4,10 A+
Pipe length range m 3 ~ 15
Heating capacity at -7°C kW 4,58
Kit KIT-BZ50-XKE
Additional gas amount g/m 15
Pipe length for additional gas m 7,5
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Indoor dimension (Depth) mm 209
Indoor dimension (Width) mm 779
Indoor recommended fuse A 16
Refrigerant (R32) / CO2 Eq. kg / T 1,14 / 0,77
EER (Nominal) (1) W/W 3,03
COP (Nominal) (1) W/W 3,42
Heating capacity (Nominal) kW 5,40
Cooling capacity (Nominal) kW 5,00
Operating range (Cool - Min) °C -10
Input power heating (Nominal) kW 1,58
Pdesign at -10°C kW 4,00

1) EER and COP calculation is based in accordance to EN14511.
2) Energy Label Scale from A+++ to D.
3) The annual energy consumption is calculated in accordance to EU/626/2011.
4) The sound pressure of the indoor unit shows the value measured of a position of 1m in front of the main body and 0,8m below the unit. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
5) Add 70mm for piping port.

Complementary products