4-Way 60x60 Cassette Inverter • R32
3.5kW
KIT-Z35-UB4 (CS-Z35UB4EAW + CU-Z35UBEA)
Specially designed for offices, retail and restaurant applications, this Cassette fits perfectly into 60x60 or 70x70 ceiling grids.
- Cassettes can be controlled by KNX and Modbus
- Designed for easy installation in the standard European 60x60 ceiling grid
- Piping length up to 30 m
- Maximum elevation difference up to 20 m
- Compact outdoor units for easy installation
- High pressure selector in case of high ceilings (higher than 2,7 m)
- Drain pump included (maximum 750 mm high)
- Air fresh entry available on the Cassette
Why install a Panasonic Air Conditioning unit?
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost - providing you with efficient heating and cooling throughout the year.
With nanoe™ X technology, they support in creating cleaner air throughout your home - free from viruses, bacteria, pollen and odours.
A range of products designed for you
Single unit solutions for 1 room or multiple units throughout your property? No problem!
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience throughout the year.
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost - providing you with efficient heating and cooling throughout the year.
With nanoe™ X technology, they support in creating cleaner air throughout your home - free from viruses, bacteria, pollen and odours.
A range of products designed for you
Single unit solutions for 1 room or multiple units throughout your property? No problem!
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience throughout the year.
Manage your Panasonic solutions anytime, anywhere
Specifications
| 4-Way 60x60 Cassette Inverter • R32 | |||
|---|---|---|---|
| 3.5 kW | |||
| Cooling capacity (Min) | kW | 0,85 | |
| Input power heating (Min) | kW | 0,23 | |
| COP (Max) (1) | W/W | 3,20 | |
| COP (Min) (1) | W/W | 3,70 | |
| Heating capacity (Max) | kW | 5,60 | |
| Heating capacity (Min) | kW | 0,85 | |
| Input power cooling (Max) | kW | 1,18 | |
| Input power cooling (Min) | kW | 0,24 | |
| EER (Max) (1) | W/W | 3,39 | |
| EER (Min) (1) | W/W | 3,54 | |
| Cooling capacity (Max) | kW | 4,00 | |
| Input power heating (Max) | kW | 1,75 | |
| Operating range (Heat - Max) | °C | +24 | |
| Operating range (Heat - Min) | °C | -15 | |
| Operating range (Cool - Max) | °C | +43 | |
| Elevation difference (in/out) (6) | m | 15 | |
| Outdoor dimension (Depth) (5) | mm | 299 | |
| Outdoor dimension (Width) (5) | mm | 824 | |
| Outdoor dimension (Height) (5) | mm | 619 | |
| Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 48 | |
| Outdoor unit | CU-Z35UBEA | ||
| Outdoor connection indoor / outdoor | mm² | — | |
| Outdoor recommended fuse | A | — | |
| Panel net weight | kg | 2,5 | |
| Panel dimension (Depth) | mm | 700 | |
| Panel dimension (Height) | mm | 51 | |
| Panel | CZ-BT20EW | ||
| Outdoor air flow (Heat) | m³/min | 33,5 | |
| Outdoor air flow (Cool) | m³/min | 34,3 | |
| Indoor unit | CS-Z35UB4EAW | ||
| Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 25 | |
| Indoor sound pressure (Heat -Lo) (4) | dB(A) | 28 | |
| Indoor sound pressure (Heat -Hi) (4) | dB(A) | 35 | |
| Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 23 | |
| Indoor sound pressure (Cool -Lo) (4) | dB(A) | 26 | |
| Moisture removal volume | L/h | 2,0 | |
| Indoor air flow (Heat) | m³/min | 10,8 | |
| Indoor air flow (Cool) | m³/min | 10,5 | |
| Indoor power source | V | 230 | |
| Annual energy consumption heating (3) | kWh/a | 1000 | |
| Annual energy consumption cooling (3) | kWh/a | 188,00 | |
| Input power cooling (Nominal) | kW | 0,90 | |
| Pdesign (cooling) | kW | 3,50 | |
| SEER (2) | 6,50 A++ | ||
| Outdoor net weight | kg | 35 | |
| Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
| Indoor net weight | kg | 18 | |
| Indoor dimension (Height) | mm | 260 | |
| Indoor sound pressure (Cool -Hi) (4) | dB(A) | 34 | |
| SCOP (2) | 4,20 A+ | ||
| Pipe length range | m | 3 ~ 20 | |
| Heating capacity at -7°C | kW | 3,37 | |
| Kit | KIT-Z35-UB4 | ||
| Additional gas amount | g/m | 10 | |
| Pipe length for additional gas | m | 7,5 | |
| Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Indoor dimension (Depth) | mm | 575 | |
| Indoor dimension (Width) | mm | 575 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 0,93 / 0,628 | |
| EER (Nominal) (1) | W/W | 3,89 | |
| COP (Nominal) (1) | W/W | 3,31 | |
| Outdoor power source | V | 230 | |
| Heating capacity (Nominal) | kW | 4,50 | |
| Cooling capacity (Nominal) | kW | 3,50 | |
| Operating range (Cool - Min) | °C | -10 | |
| Input power heating (Nominal) | kW | 1,36 | |
| Pdesign at -10°C | kW | 3,00 | |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1,5 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.