Floor Console Inverter+ • R32
3.5kW
KIT-Z35-UFE (CS-Z35UFEAW + CU-Z35UBEA)
Floor Console. Efficient comfort and clean air all year round.
Floor Console with new nanoe™ X technology: outstanding efficiency A++, comfort (Super Quiet technology only 20 dB(A)) and healthy air combined in a breakthrough design.
- nanoe™ X, technology with the benefits of hydroxyl radicals, improve protection 24/7
- Infrared control Sky Controller
- A breakthrough design that integrates perfectly with the most modern environments. We have selected the finest materials and processes for a refined design
- High energy efficiency class up to A++
- Control your comfort and the power consumption with internet control
Why install a Panasonic Air Conditioning unit?
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost - providing you with efficient heating and cooling throughout the year.
With nanoe™ X technology, they support in creating cleaner air throughout your home - free from viruses, bacteria, pollen and odours.
A range of products designed for you
Single unit solutions for 1 room or multiple units throughout your property? No problem!
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience throughout the year.
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost - providing you with efficient heating and cooling throughout the year.
With nanoe™ X technology, they support in creating cleaner air throughout your home - free from viruses, bacteria, pollen and odours.
A range of products designed for you
Single unit solutions for 1 room or multiple units throughout your property? No problem!
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience throughout the year.
Manage your Panasonic solutions anytime, anywhere
Bringing nature’s balance indoors
Specifications
| Floor Console Inverter+ • R32 | |||
|---|---|---|---|
| 3.5 kW | |||
| Cooling capacity (Min) | kW | 0,85 | |
| Input power heating (Min) | kW | 0,24 | |
| COP (Max) (1) | W/W | 3,43 | |
| COP (Min) (1) | W/W | 3,54 | |
| Heating capacity (Max) | kW | 6,00 | |
| Heating capacity (Min) | kW | 0,85 | |
| Input power cooling (Max) | kW | 1,02 | |
| Input power cooling (Min) | kW | 0,24 | |
| EER (Max) (1) | W/W | 3,73 | |
| EER (Min) (1) | W/W | 3,54 | |
| Cooling capacity (Max) | kW | 3,80 | |
| Input power heating (Max) | kW | 1,75 | |
| Operating range (Heat - Max) | °C | +24 | |
| Operating range (Heat - Min) | °C | -15 | |
| Operating range (Cool - Max) | °C | +43 | |
| Elevation difference (in/out) (6) | m | 15 | |
| Outdoor dimension (Depth) (5) | mm | 299 | |
| Outdoor dimension (Width) (5) | mm | 824 | |
| Outdoor dimension (Height) (5) | mm | 619 | |
| Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 48 | |
| Outdoor unit | CU-Z35UBEA | ||
| nanoe X Generator | Mark 1 | ||
| Outdoor connection indoor / outdoor | mm² | — | |
| Outdoor recommended fuse | A | 16 | |
| Outdoor air flow (Heat) | m³/min | 33,5 | |
| Outdoor air flow (Cool) | m³/min | 34,3 | |
| Indoor unit | CS-Z35UFEAW | ||
| Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 19 | |
| Indoor sound pressure (Heat -Lo) (4) | dB(A) | 26 | |
| Indoor sound pressure (Heat -Hi) (4) | dB(A) | 39 | |
| Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 20 | |
| Indoor sound pressure (Cool -Lo) (4) | dB(A) | 26 | |
| Moisture removal volume | L/h | 2,0 | |
| Indoor air flow (Heat) | m³/min | 10,1 | |
| Indoor air flow (Cool) | m³/min | 9,9 | |
| Indoor power source | V | 230 | |
| Annual energy consumption heating (3) | kWh/a | 974 | |
| Annual energy consumption cooling (3) | kWh/a | 151,00 | |
| Input power cooling (Nominal) | kW | 0,86 | |
| Pdesign (cooling) | kW | 3,50 | |
| SEER (2) | 8,10 A++ | ||
| Outdoor net weight | kg | 35 | |
| Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | |
| Indoor net weight | kg | 13 | |
| Indoor dimension (Height) | mm | 600 | |
| Indoor sound pressure (Cool -Hi) (4) | dB(A) | 39 | |
| SCOP (2) | 4,60 A++ | ||
| Pipe length range | m | 3 ~ 20 | |
| Heating capacity at -7°C | kW | 3,37 | |
| Kit | KIT-Z35-UFE | ||
| Additional gas amount | g/m | 10 | |
| Pipe length for additional gas | m | 7,5 | |
| Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Indoor dimension (Depth) | mm | 207 | |
| Indoor dimension (Width) | mm | 750 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 0,93 / 0,628 | |
| EER (Nominal) (1) | W/W | 4,07 | |
| COP (Nominal) (1) | W/W | 3,98 | |
| Outdoor power source | V | 230 | |
| Heating capacity (Nominal) | kW | 4,30 | |
| Cooling capacity (Nominal) | kW | 3,50 | |
| Operating range (Cool - Min) | °C | -10 | |
| Input power heating (Nominal) | kW | 1,08 | |
| Pdesign at -10°C | kW | 3,20 | |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of a position 1 m in front of the main body and 1 m above floor. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.