Low Static Pressure Hide Away Inverter • R32
6.0kW
KIT-Z60-CD3 (CS-Z60CD3EAW + CU-Z60CBEA)
Low static pressure hide-away
Designed to blend seamlessly into any interior, this slim 200 mm‑high ducted unit provides quiet, efficient comfort. Ideal for homes and small commercial spaces, it offers flexible installation options and seamless integration with building management systems.
- Compact design: Indoor unit only 200 mm high
- Flexible installation: Long piping, compact outdoor unit, air inlet from the back or bottom
- Built-in drain pump
- Optional KNX, Modbus, and BACnet connectivity
- Wired control with weekly timer
Specifications
| Low Static Pressure Hide Away Inverter • R32 | |||
|---|---|---|---|
| 6.0 kW | |||
| Cooling capacity (Min) | kW | 0,90 | |
| Input power heating (Min) | kW | 0,26 | |
| COP (Max) (1) | W/W | 3,08 | |
| COP (Min) (1) | W/W | 3,46 | |
| Heating capacity (Max) | kW | 8,00 | |
| Heating capacity (Min) | kW | 0,90 | |
| Input power cooling (Max) | kW | 2,30 | |
| Input power cooling (Min) | kW | 0,26 | |
| EER (Max) (1) | W/W | 2,83 | |
| EER (Min) (1) | W/W | 3,53 | |
| Cooling capacity (Max) | kW | 6,50 | |
| Input power heating (Max) | kW | 2,60 | |
| Operating range (Heat - Max) | °C | +24 | |
| Operating range (Heat - Min) | °C | -15 | |
| Operating range (Cool - Max) | °C | +43 | |
| Elevation difference (in/out) (6) | m | 20 | |
| Outdoor dimension (Depth) (5) | mm | 320 | |
| Outdoor dimension (Width) (5) | mm | 875 | |
| Outdoor dimension (Height) (5) | mm | 695 | |
| Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 50 | |
| Outdoor unit | CU-Z60CBEA | ||
| Outdoor connection indoor / outdoor | mm² | — | |
| Outdoor recommended fuse | A | — | |
| External static pressure (Max) (7) | Pa | 50 | |
| Outdoor air flow (Heat) | m³/min | 39,7 | |
| Outdoor air flow (Cool) | m³/min | 42,6 | |
| Indoor unit | CS-Z60CD3EAW | ||
| Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 29 | |
| Indoor sound pressure (Heat -Lo) (4) | dB(A) | 32 | |
| Indoor sound pressure (Heat -Hi) (4) | dB(A) | 41 | |
| Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 27 | |
| Indoor sound pressure (Cool -Lo) (4) | dB(A) | 30 | |
| Moisture removal volume | L/h | 2,8 | |
| Indoor air flow (Heat) | m³/min | 15,7 | |
| Indoor air flow (Cool) | m³/min | 15,7 | |
| Annual energy consumption heating (3) | kWh/a | 1.571 | |
| Annual energy consumption cooling (3) | kWh/a | 350 | |
| Input power cooling (Nominal) | kW | 2,04 | |
| Pdesign (cooling) | kW | 6,00 | |
| SEER (2) | 6,00 A+ | ||
| Outdoor net weight | kg | 43 | |
| Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 49 | |
| Indoor net weight | kg | 19 | |
| Indoor dimension (Height) | mm | 200 | |
| Indoor sound pressure (Cool -Hi) (4) | dB(A) | 41 | |
| SCOP (2) | 4,10 A+ | ||
| Pipe length range | m | 3 ~ 30 | |
| Heating capacity at -7°C | kW | 5,10 | |
| Kit | KIT-Z60-CD3 | ||
| Additional gas amount | g/m | 15 | |
| Pipe length for additional gas | m | 7,5 | |
| Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Indoor dimension (Depth) | mm | 640 | |
| Indoor dimension (Width) | mm | 750 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,13 / 0,76 | |
| EER (Nominal) (1) | W/W | 2,94 | |
| COP (Nominal) (1) | W/W | 3,24 | |
| External static pressure (Min) (7) | Pa | 15 | |
| Outdoor power source | V | 230 | |
| Heating capacity (Nominal) | kW | 7,00 | |
| Cooling capacity (Nominal) | kW | 6,00 | |
| Operating range (Cool - Min) | °C | -10 | |
| Input power heating (Nominal) | kW | 2,16 | |
| Pdesign at -10°C | kW | 4,60 | |
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position of 1,5m below the unit with 1m duct on the suction side and 2m duct on the discharge side. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612.
(5) Add 100mm for indoor unit or 70mm for outdoor unit for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) The specification listed on the table indicates values under the condition of 25Pa (2,5mmAq) which are applied for factory default setting. Change switch on PCB from Hi to S-Hi to have more than 6,0mmAq.